Dual-chamber leadless pacing: Atrioventricular synchrony in preclinical models of normal or blocked atrioventricular conduction

被引:11
|
作者
Reddy, Vivek Y. [1 ,2 ,12 ]
Neuzil, Petr [2 ]
Booth, Daniel F. [3 ]
Knops, Reinoud E. [4 ]
Doshi, Rahul N. [5 ]
Rashtian, Mayer [6 ]
V. Exner, Derek [7 ]
Banker, Rajesh S. [8 ]
Nair, Devi [9 ]
Hadadi, Cyrus A. [10 ]
Badie, Nima [3 ]
Yang, Weiqun [3 ]
Ligon, David [3 ]
Ip, James E. [11 ]
机构
[1] Icahn Sch Med Mt Sinai, New York, NY USA
[2] Homolce Hosp, Prague, Czech Republic
[3] Abbott, Sylmar, CA USA
[4] Acad Med Ctr, Amsterdam, Netherlands
[5] HonorHlth Res Inst, Scottsdale, AZ USA
[6] Huntington Hosp, Pasadena, CA USA
[7] Libin Cardiovasc Inst, Calgary, AB, Canada
[8] Hoag Mem Hosp, Newport Beach, CA USA
[9] St Bernards Heart & Vasc Ctr, Jonesboro, AR USA
[10] MedStar Washington Hosp Ctr, Washington, DC USA
[11] Weill Cornell Med Ctr, New York, NY USA
[12] Icahn Sch Med Mt Sinai, Helmsley Electrophysiol Ctr, One Gustave L Levy Pl Box 1030, New York, NY 10029 USA
关键词
Atrioventricular synchrony; Aveir; Cardiac implantable electronic device; Conduction block; DDDR; Dual-chamber; i2i; Leadless pacemaker; Wireless communication; QUALITY-OF-LIFE; PACEMAKER; SELECTION; BASE;
D O I
10.1016/j.hrthm.2023.04.005
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Dual-chamber leadless pacemakers (LPs) require robust communication between distinct right atrial (RA) and right ventricular (RV) LPs to achieve atrioventricular (AV) synchrony. OBJECTIVE The purpose of this preclinical study was to evaluate a novel, continuous implant-to-implant (i2iTM) communication meth-odology for maintaining AV-synchronous, dual-chamber DDD(R) pacing by the 2 LPs. METHODS RA and RV LPs were implanted and paired in 7 ovine sub-jects (4 with induced complete heart block). AV synchrony (% AV in-tervals ,300 ms) and i2i communication success (% successful i2i transmissions between LPs) were evaluated acutely and chronically. During acute testing, 12-lead electrocardiographic and LP diag-nostic data were collected from 5-minute recordings, in 4 postures and 2 rhythms (AP-VP and AS-VP, or AP-VS and AS-VS) per subject. Chronic i2i performance was evaluated through 23 weeks postim-plant (final i2i evaluation period: week 16-23). RESULTS Acute AV synchrony and i2i communication success across multiple postures and rhythms were median [interquartile range] 100.0% [100.0%-100.0%] and 99.9% [99.9%-99.9%], respectively. AV synchrony and i2i success rates did not differ across postures (P = .59, P = .11) or rhythms (P = 1, P = .82). During the final i2i eval-uation period, the overall i2i success was 98.9% [98.1%-99.0%]. CONCLUSION Successful AV-synchronous, dual-chamber DDD(R) leadless pacing using a novel, continuous, wireless communication modality was demonstrated across variations in posture and rhythm in a preclinical model.
引用
收藏
页码:1146 / 1155
页数:10
相关论文
共 50 条
  • [41] A DOPPLER ECHOCARDIOGRAPHIC STUDY OF THE INFLUENCE OF THE ATRIOVENTRICULAR DELAY ON TRANSMITRAL FLOW IN DUAL CHAMBER PACING
    LASCAULT, G
    ABERGEL, E
    FRANK, R
    PETITOT, JC
    FONTAINE, G
    GROSGOGEAT, Y
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1991, 84 (02): : 173 - 178
  • [42] OPTIMAL LEFT ATRIOVENTRICULAR SEQUENCE IN DUAL CHAMBER PACING - LIMITATIONS OF PROGRAMMED AV INTERVAL
    WISH, M
    FLETCHER, RD
    GOTTDIENER, JS
    COHEN, AI
    CUTLER, DJ
    ROGERS, H
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1984, 3 (02) : 507 - 507
  • [43] Persistent Atrial Fibrillation is Associated with a Poor Prognosis in Patients with Atrioventricular Block and Dual-Chamber Pacemaker
    Petrac, Dubravko
    Radeljic, Vjekoslav
    Delic-Brkljacic, Diana
    Manola, Sime
    Cindric-Bogdan, Greta
    Pavlovic, Nikola
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2012, 35 (06): : 695 - 702
  • [44] Dual-Band MIMO Antenna Data Telemetry for Dual-Chamber Leadless Cardiac Pacing on Internet of Things Environment
    Sharma, Deepti
    Tiwari, Rakesh N.
    Kanaujia, Binod Kumar
    Kumar, Sachin
    Rambabu, Karumudi
    IEEE INTERNET OF THINGS JOURNAL, 2024, 11 (05): : 9072 - 9085
  • [45] IMPORTANCE OF AN INDIVIDUALLY PROGRAMMED ATRIOVENTRICULAR DELAY AT REST AND ON WORK CAPACITY IN PATIENTS WITH DUAL-CHAMBER PACEMAKERS
    FRIELINGSDORF, J
    GERBER, AE
    DUR, P
    VUILLIOMENET, A
    BERTEL, O
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (01): : 37 - 45
  • [46] Short atrioventricular delay reduces the degree of mitral regurgitation in patients with a sequential dual-chamber pacemaker
    Rossi, R
    Muia, N
    Turco, V
    Sgura, FA
    Molinari, R
    Modena, MG
    AMERICAN JOURNAL OF CARDIOLOGY, 1997, 80 (07): : 901 - 905
  • [47] Short term outcomes with dual chamber versus single chamber pacing for atrioventricular block-A crossover trial
    Chanthanamuthu, Ragavendra
    Ramasamy, Sakthivel
    Jain, Ashish
    Anantharaj, Avinash
    Pillai, Ajith Ananthakrishna
    Satheesh, Santhosh
    Selvaraj, Raja J.
    INDIAN HEART JOURNAL, 2022, 74 (04) : 335 - 337
  • [48] Predictors of atrial fibrillation in patients with dual-chamber pacemakers: insights from the Canadian study on spontaneous atrioventricular conduction preservation (CAN-SAVER)
    Thibault, B.
    Ducharme, A.
    Dubuc, M.
    Khairy, P.
    Guerra, P. G.
    Macle, L.
    Rivard, L.
    Roy, D.
    Talajic, M.
    Nitzsche, R.
    EUROPEAN HEART JOURNAL, 2013, 34 : 489 - 489
  • [49] Echocardiographic atrioventricular interval optimization in patients with dual-chamber pacemakers and symptomatic left ventricular systolic dysfunction
    Gilligan, DM
    Sargent, D
    Ponnathpur, V
    Dan, D
    Zakaib, JS
    Ellenbogen, KA
    AMERICAN JOURNAL OF CARDIOLOGY, 2003, 91 (05): : 629 - 631
  • [50] Dual-chamber vs. single-chamber pacemaker in patients in sinus rhythm with an atrioventricular block: a nationwide cohort study
    Bodin, Alexandre
    Texier, Ivann
    Bisson, Arnaud
    Pierre, Bertrand
    Herbert, Julien
    Jacobs, Mathieu
    Nasarre, Mathieu
    Bernard, Anne
    Fauchier, Laurent
    EUROPACE, 2024, 26 (09):