Dual-chamber leadless pacing: Atrioventricular synchrony in preclinical models of normal or blocked atrioventricular conduction

被引:11
|
作者
Reddy, Vivek Y. [1 ,2 ,12 ]
Neuzil, Petr [2 ]
Booth, Daniel F. [3 ]
Knops, Reinoud E. [4 ]
Doshi, Rahul N. [5 ]
Rashtian, Mayer [6 ]
V. Exner, Derek [7 ]
Banker, Rajesh S. [8 ]
Nair, Devi [9 ]
Hadadi, Cyrus A. [10 ]
Badie, Nima [3 ]
Yang, Weiqun [3 ]
Ligon, David [3 ]
Ip, James E. [11 ]
机构
[1] Icahn Sch Med Mt Sinai, New York, NY USA
[2] Homolce Hosp, Prague, Czech Republic
[3] Abbott, Sylmar, CA USA
[4] Acad Med Ctr, Amsterdam, Netherlands
[5] HonorHlth Res Inst, Scottsdale, AZ USA
[6] Huntington Hosp, Pasadena, CA USA
[7] Libin Cardiovasc Inst, Calgary, AB, Canada
[8] Hoag Mem Hosp, Newport Beach, CA USA
[9] St Bernards Heart & Vasc Ctr, Jonesboro, AR USA
[10] MedStar Washington Hosp Ctr, Washington, DC USA
[11] Weill Cornell Med Ctr, New York, NY USA
[12] Icahn Sch Med Mt Sinai, Helmsley Electrophysiol Ctr, One Gustave L Levy Pl Box 1030, New York, NY 10029 USA
关键词
Atrioventricular synchrony; Aveir; Cardiac implantable electronic device; Conduction block; DDDR; Dual-chamber; i2i; Leadless pacemaker; Wireless communication; QUALITY-OF-LIFE; PACEMAKER; SELECTION; BASE;
D O I
10.1016/j.hrthm.2023.04.005
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Dual-chamber leadless pacemakers (LPs) require robust communication between distinct right atrial (RA) and right ventricular (RV) LPs to achieve atrioventricular (AV) synchrony. OBJECTIVE The purpose of this preclinical study was to evaluate a novel, continuous implant-to-implant (i2iTM) communication meth-odology for maintaining AV-synchronous, dual-chamber DDD(R) pacing by the 2 LPs. METHODS RA and RV LPs were implanted and paired in 7 ovine sub-jects (4 with induced complete heart block). AV synchrony (% AV in-tervals ,300 ms) and i2i communication success (% successful i2i transmissions between LPs) were evaluated acutely and chronically. During acute testing, 12-lead electrocardiographic and LP diag-nostic data were collected from 5-minute recordings, in 4 postures and 2 rhythms (AP-VP and AS-VP, or AP-VS and AS-VS) per subject. Chronic i2i performance was evaluated through 23 weeks postim-plant (final i2i evaluation period: week 16-23). RESULTS Acute AV synchrony and i2i communication success across multiple postures and rhythms were median [interquartile range] 100.0% [100.0%-100.0%] and 99.9% [99.9%-99.9%], respectively. AV synchrony and i2i success rates did not differ across postures (P = .59, P = .11) or rhythms (P = 1, P = .82). During the final i2i eval-uation period, the overall i2i success was 98.9% [98.1%-99.0%]. CONCLUSION Successful AV-synchronous, dual-chamber DDD(R) leadless pacing using a novel, continuous, wireless communication modality was demonstrated across variations in posture and rhythm in a preclinical model.
引用
收藏
页码:1146 / 1155
页数:10
相关论文
共 50 条
  • [31] LACK OF INFLUENCE OF ATRIOVENTRICULAR DELAY ON STROKE VOLUME AT REST IN PATIENTS WITH COMPLETE ATRIOVENTRICULAR-BLOCK AND DUAL CHAMBER PACING
    OCCHETTA, E
    PICCININO, C
    FRANCALACCI, G
    MAGNANI, A
    BOLOGNESE, L
    DEVECCHI, P
    ROGNONI, G
    ROSSI, P
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1990, 13 (07): : 916 - 926
  • [32] Two Is Better than One: Aveir DR Leadless Pacemaker System with Dual-Chamber Pacing
    Tang, Jonathan E.
    Guirguis, Fady
    Holloway, Jordan O.
    Wernke, Cassidy
    Reeves, Jeremy
    Kumar, Nicolas A.
    Savona, Salvatore J.
    Essandoh, Michael K.
    Iyer, Manoj H.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2025, 39 (01) : 286 - 291
  • [33] Nonischemic Super-Responders in Fusion CRT Pacing with Normal Atrioventricular Conduction
    Goanta, Emilia-Violeta
    Luca, Constantin-Tudor
    Vacarescu, Cristina
    Crisan, Simina
    Petrescu, Lucian
    Vatasescu, Radu
    Lazar, Mihai-Andrei
    Gurgu, Andra
    Turi, Vladiana-Romina
    Cozma, Dragos
    DIAGNOSTICS, 2022, 12 (09)
  • [34] Novel cause of spurious mode switching in dual-chamber pacemakers: Atrioventricular desynchronization arrhythmia
    Sweeney, MO
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2002, 13 (06) : 616 - 619
  • [35] DUAL-CHAMBER PACING FOR CARDIAC-ARRHYTHMIAS - CONTROVERSIES IN CLONING THE CONDUCTION SYSTEM
    PARSONNET, V
    BERNSTEIN, AD
    NORMAN, JC
    TEXAS HEART INSTITUTE JOURNAL, 1984, 11 (02) : 208 - 215
  • [36] Cost-effectiveness of dual-chamber pacemaker therapy: does single lead VDD pacing reduce treatment costs of atrioventricular block?
    Wiegand, UKH
    Potratz, J
    Bode, F
    Schreiber, R
    Bonnemeier, H
    Peters, W
    Katus, HA
    EUROPEAN HEART JOURNAL, 2001, 22 (02) : 174 - 180
  • [37] Short atrioventricular delay dual-chamber pacing early after coronary artery bypass grafting in patients with poor left ventricular function
    Liebold, A
    Rodig, G
    Merk, J
    Birnbaum, DE
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1998, 12 (03) : 284 - 287
  • [38] PACING IN CHILDREN AND YOUNG-ADULTS WITH NONSURGICAL ATRIOVENTRICULAR-BLOCK - COMPARISON OF SINGLE-RATE VENTRICULAR AND DUAL-CHAMBER MODES
    KARPAWICH, PP
    PERRY, BL
    FAROOKI, ZQ
    CLAPP, SK
    JACKSON, WL
    CICALESE, CA
    GREEN, EW
    AMERICAN HEART JOURNAL, 1987, 113 (02) : 316 - 321
  • [39] Transient 2:1 Atrioventricular Block with Peri-Conduction System Pacing After Leadless Pacemaker Implantation
    Najjar, Salim N.
    Bruno, Michael A.
    Lam, Wilson W.
    TEXAS HEART INSTITUTE JOURNAL, 2024, 51 (01)
  • [40] Traditional dual-chamber right ventricular pacing versus conduction system pacing in the US medicare population
    Vijayaraman, P.
    Longacre, C.
    Kron, J.
    Subzposh, F.
    Zimmerman, P.
    Butler, K.
    Crossley, G. H.
    Ellenbogen, K. A.
    EUROPEAN HEART JOURNAL, 2024, 45