The Feasibility of the Three-Dimensional Footswitch-Operated Robotic Arm Exoscope for Cochlear Implant Surgery

被引:2
|
作者
Karinen, Eerika [1 ]
Iso-Mustajaervi, Matti [2 ]
Dietz, Aarno [2 ,3 ,4 ]
机构
[1] Satasairaala Hosp, Dept Otorhinolaryngol, Pori, Finland
[2] Kuopio Univ Hosp, Dept Otorhinolaryngol, Kuopio, Finland
[3] Univ Eastern Finland, Inst Clin Med, Otorhinolaryngol, Kuopio, Finland
[4] Kuopio Univ Hosp, Dept Otorhinolaryngol, POB 100, FI-70029 Kuopio, Finland
基金
芬兰科学院;
关键词
Cochlear implantation; Complications; Ergonomics; Exoscope; Image quality; Surgical outcomes; Three-dimensional;
D O I
10.1097/MAO.0000000000003952
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
ObjectiveTo compare the three-dimensional (3D) footswitch-operated robotic arm exoscope with the operating microscope (OM) in cochlear implant surgery.Study designMatched case-control study.PatientsCochlear implantation was performed with the exoscope on unselected patients with normal temporal anatomy. The control group that underwent cochlear implantation with the OM was case matched with respect to age, anatomy, surgical technique, and type of anesthesia.InterventionsCochlear implantation performed with the 3D exoscope.Main Outcome measuresSurgical time, occupation of the operation theater, surgical results, and user experience evaluated by a questionnaire.ResultsEleven patients (13 ears) were successfully operated on with the exoscope. In the exoscope group, we observed one minor intraoperative complication, where the middle dura was exposed during mastoidectomy. Although no clear preference was evident for either device in the overall rating, the subdomain rating revealed that the exoscope's image quality was deemed inferior, especially at higher magnifications where pixelation became noticeable. The exoscope received higher scores for usability, particularly excelling in terms of surgeon's ergonomic and comfortability. There was a statistically significant difference in mean surgical time, 146 and 129 min for the exoscope and OM group, respectively.ConclusionsCochlear implant surgery was found to be feasible with a 3D exoscope. However, there is a learning curve to overcome regarding handling and the different quality of the image. The exoscope provides better ergonomics for the surgeon.
引用
收藏
页码:786 / 790
页数:5
相关论文
共 50 条
  • [1] A three-dimensional exoscope system for bilateral simultaneous cochlear implant surgery: how I do it
    Tan, S. H.
    Kulasegarah, J.
    Prepageran, N.
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2022, 136 (04): : 360 - 362
  • [2] A three-dimensional thermal model of the human cochlea for magnetic cochlear implant surgery
    Esmailie, Fateme
    Francoeur, Mathieu
    Ameel, Tim
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2021, 178
  • [3] A Fast and Reliable Three-Dimensional Centerline Tracing: Application to Virtual Cochlear Implant Surgery
    Zamani, Majid
    Salkim, Enver
    Saeed, Shakeel R.
    Demosthenous, Andreas
    IEEE ACCESS, 2020, 8 : 167757 - 167766
  • [4] Three-Dimensional Exoscope-Assisted Cleft Palate Surgery for Training
    Demirtas, Sare
    Erkol, Erden Erkut
    Tosun, Zekeriya
    TURKISH JOURNAL OF PLASTIC SURGERY, 2023, 31 (02) : 74 - 75
  • [5] New Frontiers in Pediatric Cochlear Implant Surgery - A Single Center Experience with the 3-Dimensional Exoscope
    Keane, Emma
    Bharghava, Eishaan
    Claerhout, Michiel
    Miller, Benjamin
    Pai, Irumee
    Amin, Nikul
    Jiang, Dan
    JOURNAL OF INTERNATIONAL ADVANCED OTOLOGY, 2024, 20 (05):
  • [6] Educational Benefit of the Three-Dimensional Exoscope Versus Operating Microscope in Otologic Surgery
    Tu, Nathan C.
    Doerfer, Karl
    Costeloe, Anya
    Sioshansi, Pedrom C.
    Babu, Seilesh
    OTOLOGY & NEUROTOLOGY, 2024, 45 (02) : 150 - 153
  • [7] Robotic Cochlear Implant Surgery: Imaging-Based Evaluation of Feasibility in Clinical Routine
    Auinger, Alice Barbara
    Dahm, Valerie
    Liepins, Rudolfs
    Riss, Dominik
    Baumgartner, Wolf-Dieter
    Arnoldner, Christoph
    FRONTIERS IN SURGERY, 2021, 8
  • [8] Three-dimensional localization of cochlear implant electrodes using epipolar stereophotogrammetry
    Yoo, SK
    Wang, G
    Collison, F
    Rubinstein, JT
    Vannier, MW
    Kim, FJ
    Kim, NH
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2004, 51 (05) : 838 - 846
  • [9] Experience with three-dimensional exoscope-assisted surgery of giant mastoid process osteoma
    Remacha, J.
    Navarro-Diaz, M.
    Larrosa, F.
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2022, 136 (09): : 875 - 877
  • [10] Visualization and Maneuverability Features of a Robotic Arm Three-Dimensional Exoscope and Operating Microscope for Clipping an Unruptured Intracranial Aneurysm: Video Comparison and Technical Evaluation
    Haeren, Roel
    Hafez, Ahmad
    Lehecka, Martin