Fast In-Loop Single-Tube Open-Circuit Fault Diagnosis for Voltage Source Inverter Based on Duality of Current-Time Pairs

被引:8
作者
Song, Chonghui [1 ]
Zhao, Xiaolong [1 ]
Sun, Xianrui [1 ]
Diao, Naizhe [2 ]
Zhao, Jing [3 ]
机构
[1] Northeastern Univ, Coll Informat Sci & Engn, Shenyang 110819, Peoples R China
[2] Yanshan Univ, Coll Elect Engn, Qinhuangdao 066004, Peoples R China
[3] Univ Macau, Dept Electromech Engn, Taipa 999078, Peoples R China
基金
中国国家自然科学基金;
关键词
Circuit faults; Feature extraction; Inverters; Fault diagnosis; Traction motors; Switches; Current measurement; Current-time pairs; dual-difference; neural-network-liked structure; open-circuit (OC) fault diagnosis; traction motor drive system; OPEN-SWITCH FAULTS; MODEL; CONVERTERS;
D O I
10.1109/TIE.2022.3212398
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In this article, the method extracting fault characteristics by utilizing the duality of current-time pairs is proposed to diagnose the single switch tube open-circuit (OC) fault for the inverter in the traction motor drive system. This method develops a neural-network-liked structure for OC fault diagnosis. The input layer is a fixed-period integral mean (FPIM) filter within one carrier cycle to smooth sampled discrete current-time pairs for effectively counteracting current PWM-notches and noise interference. The filtered current-time pairs are fed forward to the middle layer including functional activation functions. One of them is to normalize the current such that the diagnosis algorithm can be self-adaptive to different loads. Another one is to eliminate the singular problem near the current peak. Finally, the diagnostic functions are constructed by the dual-difference of discrete current-time pairs to quickly diagnose and locate the single-tube OC fault. It does not require additional sensors and other auxiliary detection circuits, and can accurately locate faults with few current signal nodes. It greatly reduces fault detection time and avoids triggering a vicious chain reaction due to detection delays. In addition, it also has excellent robustness under varying frequency conditions, since it is only concerned with the local property. This algorithm can be embedded in the closed-loop system due to its simple structure and low computation and storage burden. The effectiveness of the proposed method is verified through experiments.
引用
收藏
页码:9572 / 9581
页数:10
相关论文
共 27 条
[1]   Current Residual Vector-Based Open-Switch Fault Diagnosis of Inverters in PMSM Drive Systems [J].
An, Qun-Tao ;
Sun, Li ;
Sun, Li-Zhi .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (05) :2814-2827
[2]   Switching Function Model-Based Fast-Diagnostic Method of Open-Switch Faults in Inverters Without Sensors [J].
An, Qun-Tao ;
Sun, Li-Zhi ;
Zhao, Ke ;
Sun, Li .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2011, 26 (01) :119-126
[3]   An Observer-Based Diagnosis Scheme for Single and Simultaneous Open-Switch Faults in Induction Motor Drives [J].
Campos-Delgado, D. U. ;
Espinoza-Trejo, D. R. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (02) :671-679
[4]   An Improved IGBT Short-Circuit Protection Method With Self-Adaptive Blanking Circuit Based on VCE Measurement [J].
Chen, Min ;
Xu, Dehong ;
Zhang, Xingyao ;
Zhu, Nan ;
Wu, Junxiong ;
Rajashekara, Kaushik .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2018, 33 (07) :6126-6136
[5]   A Novel Diagnostic Technique for Open-Circuited Faults of Inverters Based on Output Line-to-Line Voltage Model [J].
Cheng Shu ;
Chen Ya-Ting ;
Yu Tian-Jian ;
Wu Xun .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2016, 63 (07) :4412-4421
[6]   Study and Handling Methods of Power IGBT Module Failures in Power Electronic Converter Systems [J].
Choi, Ui-Min ;
Blaabjerg, Frede ;
Lee, Kyo-Beum .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (05) :2517-2533
[7]   Open-Circuit Fault Diagnosis in PMSG Drives for Wind Turbine Applications [J].
Freire, Nuno M. A. ;
Estima, Jorge O. ;
Marques Cardoso, Antonio J. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2013, 60 (09) :3957-3967
[8]  
Gao ZW, 2015, IEEE T IND ELECTRON, V62, P3768, DOI [10.1109/TIE.2015.2417501, 10.1109/TIE.2015.2419013]
[9]   An Open-Switch Fault Diagnosis Method for Single-Phase PWM Rectifier Using a Model-Based Approach in High-Speed Railway Electrical Traction Drive System [J].
Gou, Bin ;
Ge, Xinglai ;
Wang, Shunliang ;
Feng, Xiaoyun ;
Kuo, James B. ;
Habetler, Thomas G. .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2016, 31 (05) :3816-3826
[10]   A Current-Based Approach for Short-Circuit Fault Diagnosis in Closed-Loop Current Source Inverter [J].
Guo, Xiaoqiang ;
Sui, Sen ;
Wang, Baocheng ;
Zhang, Wenlin .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2020, 67 (09) :7941-7950