Simultaneous detection of CO2/CH4 based on off-axis integrated cavity output spectroscopy and time-division-multiplexing-based wavelength modulation spectroscopy

被引:13
|
作者
Yu, Runqing [1 ,2 ]
Xia, Hua [2 ,4 ]
Pang, Tao [2 ]
Wu, Bian [2 ]
Li, Zhe [3 ]
Sun, Pengshuai [2 ]
Guo, Qiang [2 ]
Zhang, Zhirong [1 ,2 ,4 ,5 ]
Cai, Yongjun [6 ]
机构
[1] Univ Sci & Technol China, Sch Environm Sci & Optoelect Technol, Jinzhai Rd 96, Hefei 230026, Peoples R China
[2] Chinese Acad Sci, Hefei Inst Phys Sci, Anhui Inst Opt & Fine Mech, Anhui Prov Key Lab Photon Devices & Mat, Shushanhu Rd 350, Hefei 230031, Peoples R China
[3] Hefei Normal Univ, Coll Phys & Mat Engn, Hefei 230601, Peoples R China
[4] Chinese Acad Sci, Anhui Inst Opt & Fine Mech, Key Lab Environm Opt & Technol, Shushanhu Rd 350, Hefei 230031, Peoples R China
[5] Adv Laser Technol Lab Anhui Prov, Shushanhu Rd 350, Hefei 230031, Peoples R China
[6] PipeChina Gen Acad Sci & Technol, Jinguang Rd 51, Langfang 065000, Hebei, Peoples R China
基金
中国国家自然科学基金;
关键词
OA-ICOS; CO2; CH4; Time-division-multiplexing; WMS; Simultaneous detection; LASER-ABSORPTION-SPECTROSCOPY; WHITE-NOISE; SENSITIVITY; SENSOR;
D O I
10.1016/j.optcom.2023.129731
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A highly sensitive dual gases detection system was established for detecting the concentrations of carbon dioxide (CO2) and methane (CH4) simultaneously based on off-axis integrated cavity output spectroscopy (OAICOS) technology. Two Distributed Feedback (DFB) lasers with central wavelengths of 1580 nm and 1653 nm were used as the light sources of the system. A time-division-multiplexing-based wavelength modulation spectroscopy (WMS) method was used to scan the current of lasers for improving the signal-to-noise ratio of the system and getting the optimal modulation amplitudes of CO2 and CH4 simultaneously. In addition, the cavity mode noise was suppressed by radio frequency (RF) white noise loading and laser current to further improve the measurement accuracy. Allan deviation analysis indicates that measurement precision of 0.483 ppm for CO2 and 1.37 ppb for CH4 was achieved by averaging up to 993 s and 1093 s respectively. This compact and high-precision measurement system is suitable for measuring atmospheric greenhouse gases.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Detection of formaldehyde using off-axis integrated cavity output spectroscopy with an interband cascade laser
    Miller, J. H.
    Bakhirkin, Y. A.
    Ajtai, T.
    Tittel, F. K.
    Hill, C. J.
    Yang, R. Q.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2006, 85 (2-3): : 391 - 396
  • [32] Detection of formaldehyde using off-axis integrated cavity output spectroscopy with an interband cascade laser
    J.H. Miller
    Y.A. Bakhirkin
    T. Ajtai
    F.K. Tittel
    C.J. Hill
    R.Q. Yang
    Applied Physics B, 2006, 85 : 391 - 396
  • [33] Sensitive hydrogen detection using off-axis integrated cavity output spectroscopy at 2.1 μm
    Duan, Kun
    Hu, Mai
    Wang, Zhen
    Lyu, Guanda
    Ren, Wei
    APPLIED PHYSICS LETTERS, 2025, 126 (04)
  • [34] Off-axis integrated cavity output spectroscopy for real-time methane measurements with an integrated wavelength-tunable light source
    He, Qixin
    Zheng, Chuantao
    Zheng, Kaiyuan
    Tittel, Frank K.
    INFRARED PHYSICS & TECHNOLOGY, 2021, 115
  • [35] Simultaneous detection of greenhouse gases CH4 and CO2 based on a dual differential photoacoustic spectroscopy system
    Wang, Fupeng
    Wu, Jinghua
    Cheng, Yaopeng
    Fu, Liyan
    Zhang, Jianguo
    Wang, Qiang
    OPTICS EXPRESS, 2023, 31 (21) : 33898 - 33913
  • [36] Extremely sensitive detection of NO2 employing off-axis integrated cavity output spectroscopy coupled with multiple-line integrated absorption spectroscopy
    Rao, Gottipaty N.
    Karpf, Andreas
    APPLIED OPTICS, 2011, 50 (13) : 1915 - 1924
  • [37] No influence of CO2 on stable isotope analyses of soil waters with off-axis integrated cavity output spectroscopy (OA-ICOS)
    Sprenger, Matthias
    Tetzlaff, Doerthe
    Soulsby, Chris
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2017, 31 (05) : 430 - 436
  • [38] A Quartz-Enhanced Photothermal Spectroscopy for C2H2 and CH4 Detection Based on Time Division Multiplexing Technology
    Fu, Yulong
    Zhang, Hengbiao
    Bi, Shaoqiang
    Zhao, Jing
    Shi, Jingqi
    Zhao, Yiyang
    Qin, Lu
    Wang, Zongliang
    IEEE SENSORS JOURNAL, 2024, 24 (21) : 34440 - 34447
  • [39] Mid-infrared quantum cascade laser based off-axis integrated cavity output spectroscopy for biogenic nitric oxide detection
    Bakhirkin, YA
    Kosterev, AA
    Roller, C
    Curl, RF
    Tittel, FK
    APPLIED OPTICS, 2004, 43 (11) : 2257 - 2266
  • [40] Real-time, subsecond, multicomponent breath analysis by Optical Parametric Oscillator based Off-Axis Integrated Cavity Output Spectroscopy
    Arslanov, Denis D.
    Swinkels, Koen
    Cristescu, Simona M.
    Harren, Frans J. M.
    OPTICS EXPRESS, 2011, 19 (24): : 24078 - 24089