Plate Fixation of Proximal Humerus Fractures: How to Get It Right and Future Directions for Improvement

被引:10
作者
Foruria, Antonio M. [1 ]
机构
[1] Univ Autonoma Madrid, Shoulder & Elbow Reconstruct Surg Unit, Orthoped Surg, Fdn Jimenez Diaz Univ Hosp, Ave Reyes Catolicos 2, Madrid, Spain
关键词
Proximal humerus fracture; Locking plate; Cement augmentation; Bone cement; Cemented screws; Implant failure; LOCKING INTRAMEDULLARY NAILS; ANGULAR STABLE PLATE; INTERNAL-FIXATION; OPEN REDUCTION; LOCKED-PLATE; SHOULDER ARTHROPLASTY; EARLY COMPLICATIONS; SURGICAL-TREATMENT; COMPRESSION PLATE; MEDIAL SUPPORT;
D O I
10.1007/s12178-023-09853-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose of ReviewOpen reduction and internal fixation with locking plates (ORIF-LP) has been used for decades for the surgical management of proximal humerus fractures. Despite good outcomes have been widely published in the literature, unacceptably high rates of complications (up to 40%), many of them yielding poor outcomes and requiring reoperation (up to 25%), have also been reported, especially in elderly patients. Most common complications are related to implant failure, with intra-articular screw penetration as the most frequent and devastating.Recent FindingsAdvances in patient selection and surgical technique, and implementation of bone or cement augmentation, have been developed to hopefully decrease complication rates. Mayo-FJD Classification offers prognostic information that can aid in the decision-making process for proximal humeral fractures. Displaced valgus impacted fractures seem to be associated with well over a 10% rate of avascular necrosis after ORIF-LP. A principle-based and stepwise surgical technique combining anatomic reduction and a short screw configuration can provide good outcome in most patients, even the elderly, decreasing implant failures to less than 10%. Acrylic cement augmentation has the potential to further decrease implant failure rate to 1%. Reoperation rates are higher partly due to the need to remove hardware for painful subacromial conflict. However, no studies to date definitively demonstrated the superiority of ORIF-LP compared to non-operative treatment, intramedullary nailing, or reverse shoulder arthroplasty.ORIF-LP can provide good results for the surgical management of displaced proximal humerus fractures even in elderly patients provided adequate patient selection and a principle based and stepwise surgical technique, supplemented with bone graft or acrylic cement when needed. Poor outcomes and high complication and reoperation rates should be expected when these recommendations are not followed.
引用
收藏
页码:457 / 469
页数:13
相关论文
共 78 条
[11]   Treatment of comminuted proximal humeral fractures using locking plate with strut allograft [J].
Cha, Hongeun ;
Park, Ki-Beom ;
Oh, Seungbae ;
Jeong, Jinyoung .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2017, 26 (05) :781-785
[12]   Proximal humeral internal locking system (PHILOS) for the treatment of proximal humeral fractures [J].
Charalambous, C. P. ;
Siddique, I. ;
Valluripalli, K. ;
Kovacevic, M. ;
Panose, P. ;
Srinivasan, M. ;
Marynissen, H. .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2007, 127 (03) :205-210
[13]   Three- and four-part displaced proximal humeral fractures in patients older than 70 years: reverse shoulder arthroplasty or nonsurgical treatment? [J].
Chivot, Matthieu ;
Lami, Damien ;
Bizzozero, Paul ;
Galland, Alexandre ;
Argenson, Jean-Noel .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2019, 28 (02) :252-259
[14]   Risk factors for proximal humerus fracture [J].
Chu, SP ;
Kelsey, JL ;
Keegan, THM ;
Sternfeld, B ;
Prill, M ;
Quesenberry, CP ;
Sidney, S .
AMERICAN JOURNAL OF EPIDEMIOLOGY, 2004, 160 (04) :360-367
[15]   Pitfalls and complications with locking plate for proximal humerus fracture [J].
Clavert, Philippe ;
Adam, Philippe ;
Bevort, Adrien ;
Bonnomet, Francois ;
Kempf, Jean-Francois .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2010, 19 (04) :489-494
[16]   The epidemiology of proximal humeral fractures [J].
Court-Brown, CM ;
Garg, A ;
McQueen, MM .
ACTA ORTHOPAEDICA SCANDINAVICA, 2001, 72 (04) :365-371
[17]   Natural history of complex fractures of the proximal humerus using a three-dimensional classification system [J].
Edelson, Gordon ;
Safuri, Husam ;
Salami, Joseph ;
Vigder, Fina ;
Militianu, Daniela .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2008, 17 (03) :399-409
[18]   Early complications in proximal humerus fractures (OTA types 11) treated with locked plates [J].
Egol, Kenneth A. ;
Ong, Crispin C. ;
Walsh, Michael ;
Dazrawi, Laith M. ;
Tejwani, Nirmal C. ;
Zuckerman, Joseph D. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2008, 22 (03) :159-164
[19]   Early results in the treatment of proximal humeral fractures with a polyaxial locking plate [J].
Erhardt, Johannes B. ;
Roderer, G. ;
Grob, K. ;
Forster, T. N. ;
Stoffel, K. ;
Kuster, M. S. .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2009, 129 (10) :1367-1374
[20]   Surgical Treatment With an Angular Stable Plate for Complex Displaced Proximal Humeral Fractures in Elderly Patients: A Randomized Controlled Trial [J].
Fjalestad, Tore ;
Hole, Margrethe O. ;
Hovden, Inger Anette Hynas ;
Blucher, Judith .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2012, 26 (02) :98-106