High-throughput, rapid and non-invasive readouts of tissue health in microfluidic kidney co-culture models would expand their capabilities for pre-clinical assessment of drug-induced nephrotoxicity. Here, we demonstrate a technique for monitoring steady state oxygen levels in PREDICT96-O-2, a high-throughput organ-on-chip platform with integrated optical-based oxygen sensors, for evaluation of drug-induced nephrotoxicity in a human microfluidic co-culture model of the kidney proximal tubule (PT). Oxygen consumption measurements in PREDICT96-O-2 detected dose and time-dependent injury responses of human PT cells to cisplatin, a drug with known toxic effects in the PT. The injury concentration threshold of cisplatin decreased exponentially from 19.8 mu M after 1 day to 2.3 mu M following a clinically relevant exposure duration of 5 days. Additionally, oxygen consumption measurements resulted in a more robust and expected dose-dependent injury response over multiple days of cisplatin exposure compared to colorimetric-based cytotoxicity readouts. The results of this study demonstrate the utility of steady state oxygen measurements as a rapid, non-invasive, and kinetic readout of drug-induced injury in high-throughput microfluidic kidney co-culture models.
引用
收藏
页码:3204 / 3216
页数:13
相关论文
共 62 条
[1]   Microfluidic heart on a chip for higher throughput pharmacological studies [J].
Agarwal, Ashutosh ;
Goss, Josue Adrian ;
Cho, Alexander ;
McCain, Megan Laura ;
Parker, Kevin Kit .
LAB ON A CHIP, 2013, 13 (18) :3599-3608
[2]   Influence of microvascular endothelial cells on transcriptional regulation of proximal tubular epithelial cells [J].
Aydin, Sonia ;
Signorelli, Sara ;
Lechleitner, Thomas ;
Joannidis, Michael ;
Pleban, Clara ;
Perco, Paul ;
Pfaller, Walter ;
Jennings, Paul .
AMERICAN JOURNAL OF PHYSIOLOGY-CELL PHYSIOLOGY, 2008, 294 (02) :C543-C554
[3]   Microfluidic-Based Oxygen (O2) Sensors for On-Chip Monitoring of Cell, Tissue and Organ Metabolism [J].
Azimzadeh, Mostafa ;
Khashayar, Patricia ;
Amereh, Meitham ;
Tasnim, Nishat ;
Hoorfar, Mina ;
Akbari, Mohsen .
BIOSENSORS-BASEL, 2022, 12 (01)
[4]   High-throughput organ-on-chip platform with integrated programmable fluid flow and real-time sensing for complex tissue models in drug development workflows† [J].
Azizgolshani, H. ;
Coppeta, J. R. ;
Vedula, E. M. ;
Marr, E. E. ;
Cain, B. P. ;
Luu, R. J. ;
Lech, M. P. ;
Kann, S. H. ;
Mulhern, T. J. ;
Tandon, V. ;
Tan, K. ;
Haroutunian, N. J. ;
Keegan, P. ;
Rogers, M. ;
Gard, A. L. ;
Baldwin, K. B. ;
de Souza, J. C. ;
Hoefler, B. C. ;
Bale, S. S. ;
Kratchman, L. B. ;
Zorn, A. ;
Patterson, A. ;
Kim, E. S. ;
Petrie, T. A. ;
Wiellette, E. L. ;
Williams, C. ;
Isenberg, B. C. ;
Charest, J. L. .
LAB ON A CHIP, 2021, 21 (08) :1454-1474
[5]   Mitochondrial energetics in the kidney [J].
Bhargava, Pallavi ;
Schnellmann, Rick G. .
NATURE REVIEWS NEPHROLOGY, 2017, 13 (10) :629-646
[6]   A 3D microfluidic liver model for high throughput compound toxicity screening in the OrganoPlate® [J].
Bircsak, Kristin M. ;
DeBiasio, Richard ;
Miedel, Mark ;
Alsebahi, Alaa ;
Reddinger, Ryan ;
Saleh, Anthony ;
Shun, Tongying ;
Vernetti, Lawrence A. ;
Gough, Albert .
TOXICOLOGY, 2021, 450
[7]   Microfluidic oxygen sensor system as a tool to monitor the metabolism of mammalian cells [J].
Bunge, Frank ;
van den Driesche, Sander ;
Waespy, Mario ;
Radtke, Arlo ;
Belge, Gazanfer ;
Kelm, Sorge ;
Waite, Anya M. ;
Mirastschijski, Ursula ;
Vellekoop, Michael J. .
SENSORS AND ACTUATORS B-CHEMICAL, 2019, 289 :24-31
[8]   CONTINUOUS, NON-INVASIVE MONITORING OF OXYGEN CONSUMPTION IN A PARALLELIZED MICROFLUIDIC IN VITRO SYSTEM PROVIDES NOVEL INSIGHT INTO THE RESPONSE TO NUTRIENTS AND DRUGS OF PRIMARY HUMAN HEPATOCYTES [J].
Busche, Marius ;
Rabl, Dominik ;
Fischer, Jan ;
Schmees, Christian ;
Mayr, Torsten ;
Gebhardt, Rolf ;
Stelzle, Martin .
EXCLI JOURNAL, 2022, 21 :144-161
[9]   Mechanism and reversal of drug-induced nephrotoxicity on a chip [J].
Cohen, Aaron ;
Ioannidis, Konstantinos ;
Ehrlich, Avner ;
Regenbaum, Shaun ;
Cohen, Merav ;
Ayyash, Muneef ;
Tikva, Sigal Shafran ;
Nahmias, Yaakov .
SCIENCE TRANSLATIONAL MEDICINE, 2021, 13 (582)
[10]   MAXIMUM LIKELIHOOD FROM INCOMPLETE DATA VIA EM ALGORITHM [J].
DEMPSTER, AP ;
LAIRD, NM ;
RUBIN, DB .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES B-METHODOLOGICAL, 1977, 39 (01) :1-38