Ovarian-Adnexal Reporting and Data System for Magnetic Resonance Imaging (O-RADS MRI): Genesis and Future Directions

被引:4
|
作者
Nougaret, Stephanie [1 ,2 ,9 ]
Lakhman, Yulia [3 ]
Bahadir, Suzan [4 ]
Sadowski, Elizabeth [5 ]
Thomassin-Naggara, Isabelle [6 ]
Reinhold, Caroline [7 ,8 ]
机构
[1] Montpellier Canc Inst ICM, Dept Radiol, Montpellier, France
[2] Univ Montpellier, Montpellier Canc Res Inst IRCM, INSERM U1194, Montpellier, France
[3] Mem Sloan Kettering Canc Ctr, Dept Radiol, New York, NY USA
[4] Baskent Univ, Dept Radiol, Antalya, Turkiye
[5] Univ Wisconsin, Sch Med & Publ Hlth, Dept Radiol & Obstet & Gynecol, Madison, WI USA
[6] Sorbonne Univ, Assistance Publ Hop Paris, Serv Imageries Radiol & Intervent Specialisees IRI, Paris, France
[7] McGill Univ Hlth Ctr MUHC, Dept Radiol, Montreal, PQ, Canada
[8] MUHC Res Inst, Dept Radiol, Augmented Intelligence Precis Lab AIPHL, Montreal, PQ, Canada
[9] Inst Reg Canc Montpellier, Serv Radiol, 208 Ave Apothicaires, F-34298 Montpellier, France
来源
CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES | 2023年 / 74卷 / 02期
基金
美国国家卫生研究院;
关键词
magnetic resonance imaging; ovarian-adnexal reporting and data system; ovarian cancer; reporting; ultrasound; SCORING SYSTEM; IOTA GROUP; MASSES; VALIDATION; GUIDELINES;
D O I
10.1177/08465371221121738
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Imaging plays an important role in characterizing and risk-stratifying commonly encountered adnexal lesions. Recently, the American College of Radiology (ACR) released the Ovarian-Adnexal Reporting and Data System (O-RADS) for ultrasound and subsequently for magnetic resonance imaging (MRI). The goal of the recently developed ACR O-RADS MRI risk stratification system is to improve the quality of imaging reports as well as the reproducibility of evaluating adnexal lesions on MRI. This review focuses on exploring this new system and its future refinements.
引用
收藏
页码:370 / 381
页数:12
相关论文
共 50 条
  • [31] Diagnostic accuracy of magnetic resonance imaging (MRI) prostate imaging reporting and data system (PI-RADS) scoring in a transperineal prostate biopsy setting
    Grey, Alistair D. R.
    Chana, Manik S.
    Popert, Rick
    Wolfe, Konrad
    Liyanage, Sidath H.
    Acher, Peter L.
    BJU INTERNATIONAL, 2015, 115 (05) : 728 - 735
  • [32] Current and Future Applications of Magnetic Resonance Imaging (MRI) to Breast and Ovarian Cancer Patient Management
    Klostergaard, Jim
    Parga, Kenia
    Raptis, Raphael G.
    PUERTO RICO HEALTH SCIENCES JOURNAL, 2010, 29 (03) : 223 - 231
  • [33] Apparent Diffusion Coefficient to Subdivide Breast Imaging Reporting and Data System Magnetic Resonance Imaging (BI-RADS-MRI) Category 4 Lesions
    Liu, Dandan
    Ba, Zhaogui
    Ni, Xiaoli
    Wang, Linhong
    Yu, Dexin
    Ma, Xiangxing
    MEDICAL SCIENCE MONITOR, 2018, 24 : 2180 - 2188
  • [34] Standardized Reporting of Prostate MRI: Comparison of the Prostate Imaging Reporting and Data System (PI-RADS) Version 1 and Version 2
    Tewes, Susanne
    Mokov, Nikolaj
    Hartung, Dagmar
    Schick, Volker
    Peters, Inga
    Schedl, Peter
    Pertschy, Stefanie
    Wacker, Frank
    Voshage, Goetz
    Hueper, Katja
    PLOS ONE, 2016, 11 (09):
  • [35] Diagnostic value of the gynecology imaging reporting and data system (GI-RADS) with the ovarian malignancy marker CA-125 in preoperative adnexal tumor assessment
    Migda, Michal
    Bartosz, Migda
    Migda, Marian S.
    Kierszk, Marcin
    Katarzyna, Gieryn
    Malenczyk, Marek
    JOURNAL OF OVARIAN RESEARCH, 2018, 11
  • [36] Diagnostic Performance of O-RADS MRI Scoring System for the Assessment of Adnexal Masses in Routine Clinical Radiology Practice- A Single Tertiary Centre Prospective Cohort Study
    Basu, Aniruddha
    Pame, Mukheswar
    Bhuyan, Rupak
    Roy, Deep Kumar
    James, Vivek Mathew
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2022, 16 (04) : TC11 - TC16
  • [37] Use of the Prostate Imaging Reporting and Data System (PI-RADS) for Prostate Cancer Detection with Multiparametric Magnetic Resonance Imaging: A Diagnostic Meta-analysis
    Hamoen, Esther H. J.
    de Rooij, Maarten
    Witjes, J. Alfred
    Barentsz, Jelle O.
    Rovers, Maroeska M.
    EUROPEAN UROLOGY, 2015, 67 (06) : 1112 - 1121
  • [38] Assessment of the O-RADS scoring system for the differentiation of different types of ovarian neoplasms: A modified approach with non-DCE-MRI
    Chen, Tong
    Qian, Xujun
    Zhu, Zhi
    Zhang, Yueyue
    Wei, Chaogang
    Shen, Xiaohong
    Zhang, Caiyuan
    Shen, Junkang
    CLINICAL IMAGING, 2024, 116
  • [39] Diagnostic value of the gynecology imaging reporting and data system (GI-RADS) with the ovarian malignancy marker CA-125 in preoperative adnexal tumor assessment
    Michal Migda
    Migda Bartosz
    Marian S. Migda
    Marcin Kierszk
    Gieryn Katarzyna
    Marek Maleńczyk
    Journal of Ovarian Research, 11
  • [40] Pitfalls and problems to be solved in the diagnostic CT/MRI Liver Imaging Reporting and Data System (LI-RADS)
    Yeun-Yoon Kim
    Jin-Young Choi
    Claude B. Sirlin
    Chansik An
    Myeong-Jin Kim
    European Radiology, 2019, 29 : 1124 - 1132