In Situ Laser Fenestration Technique: Bench-Testing of Aortic Endograft to Guide Clinical Practice

被引:15
作者
Grima, Matthew Joe [1 ,2 ,3 ]
Wanhainen, Anders [1 ,4 ]
Lindstrom, David [1 ]
机构
[1] Uppsala Univ, Dept Surg Sci, Sect Vasc Surg, Uppsala, Sweden
[2] Univ Malta, Fac Med & Surg, L Imsida, Malta
[3] Mater Dei Hosp, Dept Gen Surg, Vasc Unit, L Imsida, Malta
[4] Umea Univ, Dept Surg & Perioperat Sci, Surg, Umea, Sweden
关键词
aorta; laser; stents; fenestration; endovascular procedures; ENDOVASCULAR REPAIR; STENT-GRAFT; ABLATION; OUTCOMES;
D O I
10.1177/15266028221119315
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: In situ laser fenestration (ISLF) is a recently introduced technology that offers the potential to perform total endovascular treatment of aortic arch and thoracoabdominal aortic pathologies in the acute setting. This experiment's aim was to assess ISLF in some currently common aortic endografts and bridging stent-grafts. Materials and Methods: Three different aortic endografts were evaluated: (1) Zenith Alpha, (2) Zenith TX2, and (3) Conformable GORE TAG. Each endograft was submerged in 37 degrees C saline to create fenestrations using the 308 nm CVX-300 Excimer Laser System fitted with a 2.3 mm diameter Turbo-Elite laser atherectomy catheter compatible with a 0.018 '' guidewire. Three different 8 mm bridging stent-grafts were evaluated: (1) BeGraft peripheral, (2) BeGraft peripheral plus, and (3) GORE VIABAHN VBX Balloon Expandable. All bridging stent-grafts were deployed and exposed to different balloon sizes and pressures. The ISLFs and bridging stent-grafts were then evaluated for any tears, stenoses, and seal. Results: A laser fenestration was consistently rapidly obtained in the Zenith Alpha and the Zenith TX2 endografts while it proved difficult to achieve a timely fenestration in the C-TAG. No fabric tears were noted in the Zenith Alpha and Zenith TX2 when inflating Armada (Abbott) 8 mm balloon in the fenestrations with pressures up to 15 atmospheres (rated burst pressure) nor when flaring bridging stent-grafts with balloons up to 12 mm in diameter at 10 atmospheres, while major tears were frequently noted in the C-TAG when the Armada 8 mm balloons were inflated. BeGraft Peripheral and BeGraft Peripheral Plus were all firmly attached to the fenestrations showing good seal on manual testing, while every sixth VBX bridging stent-graft displayed poorer attachment to the fenestration before dilatation at high pressure. Commonly, significant stenoses remained in the bridging stent-grafts after dilatation at nominal pressure, which could only be eradicated with high-pressure balloons. Conclusion: In this limited bench-test, Dacron endografts responded well to the ISLF technology. Satisfactory deployment of the bridging stent was noted only after inflation and/or flaring with high-pressure balloons. Further work with different types of commercially-available bridging stent-grafts and endografts to assess the durability of in situ fenestration (ISF) and bridging stents in ISF is recommended. Clinical Impact This report on experimental in situ laser fenestration provide important insights for clinicians considering using in situ laser fenestration of aortic stentgrafts in vivo. In particular, different laser settings were tested together with a selection of aortic stentgrafts. Also, the target pressure needed in PTA balloons to dilate the fenestrations and any subsequent tears in the fabric were noted. This was followed by deployment of assorted balloon-expandable stentgrafts with estimation of residual stenosis and seal.
引用
收藏
页码:126 / 131
页数:6
相关论文
共 24 条
  • [11] Aneurysm Rupture and Mortality During the Waiting Time for a Customised Fenestrated/Branched Stent Graft in Complex Endovascular Aortic Repair
    Katsargyris, Athanasios
    Uthayakumar, Vasuki
    de Marino, Pablo Marques
    Botos, Balazs
    Verhoeven, Eric L.
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2020, 60 (01) : 44 - 48
  • [12] HAZARDOUS CHEMICALS PRODUCED BY LASER MATERIALS PROCESSING
    KOKOSA, JM
    [J]. JOURNAL OF LASER APPLICATIONS, 1994, 6 (04) : 195 - 201
  • [13] KUPER S, 1989, APPL PHYS LETT, V54, P4, DOI 10.1063/1.100831
  • [14] In Situ Antegrade Laser Fenestrations During Endovascular Aortic Repair
    Le Houerou, Thomas
    Fabre, Dominique
    Alonso, Carlos G.
    Brenot, Philippe
    Bourkaib, Ryiad
    Angel, Claude
    Amsallem, Myriam
    Haulon, Stephan
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2018, 56 (03) : 356 - 362
  • [15] Experimental Analysis of the Quality of Needle-Assisted Fenestration in Aortic Stent-Grafts and the Differences Between Gradual and Rapid Balloon Dilation
    Li, Dong-lin
    Zeng, Qing-long
    Xiang, Yi-lang
    Qiu, Chen-yang
    Li, Zhen-jiang
    He, Yang-yan
    Zhu, Qian-qian
    Wu, Zi-heng
    Wang, Xun
    Zhang, Hong-kun
    [J]. JOURNAL OF ENDOVASCULAR THERAPY, 2021, 28 (01) : 44 - 52
  • [16] LIN J, 2016, MATERIALS, V9, DOI DOI 10.3390/MA9020113
  • [17] Optimal In Situ Fenestration Technique With Laser Perforation and Balloon Dilation for Aortic Stent-Grafts
    Lin, Jing
    Rodriguez, Limael E.
    Nutley, Mark
    Jun, Lu
    Mao, Ying
    Parikh, Niraj
    Alie-Cusson, Fanny
    Zhang, Ze
    Wang, Lu
    Panneton, Jean M.
    Guidoin, Robert
    [J]. JOURNAL OF ENDOVASCULAR THERAPY, 2021, 28 (02) : 300 - 308
  • [18] Laser Fenestration of Aortic Stent-Grafts Followed by Noncompliant vs Cutting Balloon Dilation: A Scanning Electron Microscopy Study
    Lin, Jing
    Parikh, Niraj
    Udgiri, Naval
    Wang, Shaoxia
    Miller, Daniel F.
    Li, Chaojing
    Panneton, Jean
    Nutley, Mark
    Zhang, Ze
    Huang, Yunfan
    Lu, Jun
    Zhang, Jingyi
    Wang, Lu
    Guidoin, Robert
    [J]. JOURNAL OF ENDOVASCULAR THERAPY, 2018, 25 (03) : 397 - 407
  • [19] EVAR and complex anatomy: An update on fenestrated and branched stent grafts
    Malina, M.
    Resch, T.
    Sonesson, B.
    [J]. SCANDINAVIAN JOURNAL OF SURGERY, 2008, 97 (02) : 195 - 204
  • [20] Endovascular repair of thoracoabdominal aortic aneurysm using the off-the-shelf multibranched t-Branch stent graft
    Mendes, Bernardo C.
    Oderich, Gustavo S.
    [J]. JOURNAL OF VASCULAR SURGERY, 2016, 63 (05) : 1394 - U579