In Situ Laser Fenestration Technique: Bench-Testing of Aortic Endograft to Guide Clinical Practice

被引:15
作者
Grima, Matthew Joe [1 ,2 ,3 ]
Wanhainen, Anders [1 ,4 ]
Lindstrom, David [1 ]
机构
[1] Uppsala Univ, Dept Surg Sci, Sect Vasc Surg, Uppsala, Sweden
[2] Univ Malta, Fac Med & Surg, L Imsida, Malta
[3] Mater Dei Hosp, Dept Gen Surg, Vasc Unit, L Imsida, Malta
[4] Umea Univ, Dept Surg & Perioperat Sci, Surg, Umea, Sweden
关键词
aorta; laser; stents; fenestration; endovascular procedures; ENDOVASCULAR REPAIR; STENT-GRAFT; ABLATION; OUTCOMES;
D O I
10.1177/15266028221119315
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: In situ laser fenestration (ISLF) is a recently introduced technology that offers the potential to perform total endovascular treatment of aortic arch and thoracoabdominal aortic pathologies in the acute setting. This experiment's aim was to assess ISLF in some currently common aortic endografts and bridging stent-grafts. Materials and Methods: Three different aortic endografts were evaluated: (1) Zenith Alpha, (2) Zenith TX2, and (3) Conformable GORE TAG. Each endograft was submerged in 37 degrees C saline to create fenestrations using the 308 nm CVX-300 Excimer Laser System fitted with a 2.3 mm diameter Turbo-Elite laser atherectomy catheter compatible with a 0.018 '' guidewire. Three different 8 mm bridging stent-grafts were evaluated: (1) BeGraft peripheral, (2) BeGraft peripheral plus, and (3) GORE VIABAHN VBX Balloon Expandable. All bridging stent-grafts were deployed and exposed to different balloon sizes and pressures. The ISLFs and bridging stent-grafts were then evaluated for any tears, stenoses, and seal. Results: A laser fenestration was consistently rapidly obtained in the Zenith Alpha and the Zenith TX2 endografts while it proved difficult to achieve a timely fenestration in the C-TAG. No fabric tears were noted in the Zenith Alpha and Zenith TX2 when inflating Armada (Abbott) 8 mm balloon in the fenestrations with pressures up to 15 atmospheres (rated burst pressure) nor when flaring bridging stent-grafts with balloons up to 12 mm in diameter at 10 atmospheres, while major tears were frequently noted in the C-TAG when the Armada 8 mm balloons were inflated. BeGraft Peripheral and BeGraft Peripheral Plus were all firmly attached to the fenestrations showing good seal on manual testing, while every sixth VBX bridging stent-graft displayed poorer attachment to the fenestration before dilatation at high pressure. Commonly, significant stenoses remained in the bridging stent-grafts after dilatation at nominal pressure, which could only be eradicated with high-pressure balloons. Conclusion: In this limited bench-test, Dacron endografts responded well to the ISLF technology. Satisfactory deployment of the bridging stent was noted only after inflation and/or flaring with high-pressure balloons. Further work with different types of commercially-available bridging stent-grafts and endografts to assess the durability of in situ fenestration (ISF) and bridging stents in ISF is recommended. Clinical Impact This report on experimental in situ laser fenestration provide important insights for clinicians considering using in situ laser fenestration of aortic stentgrafts in vivo. In particular, different laser settings were tested together with a selection of aortic stentgrafts. Also, the target pressure needed in PTA balloons to dilate the fenestrations and any subsequent tears in the fabric were noted. This was followed by deployment of assorted balloon-expandable stentgrafts with estimation of residual stenosis and seal.
引用
收藏
页码:126 / 131
页数:6
相关论文
共 24 条
  • [1] Clinical outcomes and material properties of in situ fenestration of endovascular stent grafts
    Crawford, Sean A.
    Sanford, Ryan M.
    Forbes, Thomas L.
    Amon, Cristina H.
    Doyle, Matthew G.
    [J]. JOURNAL OF VASCULAR SURGERY, 2016, 64 (01) : 244 - 250
  • [2] On the Merits of Branching, Debranching, and Exclusions: Will Laser-Assisted In-Situ Stent-Graft Fenestration Enter the Mix?
    Criado, Frank J.
    [J]. JOURNAL OF ENDOVASCULAR THERAPY, 2009, 16 (04) : 464 - 465
  • [3] Cross J, 2012, BRIT J SURG, V99, P152, DOI 10.1002/bjs.7804
  • [4] Frequency and type of interval adverse events during the waiting period to complex aortic endovascular repair
    D'Oria, Mario
    Wanhainen, Anders
    Mani, Kevin
    Lindstrom, David
    [J]. JOURNAL OF VASCULAR SURGERY, 2022, 75 (06) : 1821 - +
  • [5] Long-term results of total endovascular repair of arch-involving aortic pathologies using parallel grafts for supra-aortic debranching
    Dueppers, Philip
    Reutersberg, Benedikt
    Rancic, Zoran
    Messmer, Florian
    Menges, Anna-Leonie
    Meuli, Lorenz
    Rychla, Miriam
    Zimmermann, Alexander
    [J]. JOURNAL OF VASCULAR SURGERY, 2022, 75 (03) : 813 - +
  • [6] A Comprehensive Review of In Situ Fenestration of Aortic Endografts
    Glorion, M.
    Coscas, R.
    McWilliams, R. G.
    Javerliat, I.
    Goeau-Brissonniere, O.
    Coggia, M.
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2016, 52 (06) : 787 - 800
  • [7] Honing the Technique of In Situ Stent-Graft Fenestration
    Guidoin, Robert
    Lin, Jing
    Nutley, Mark
    Panneton, Jean
    Wang, Lu
    Zhang, Ze
    [J]. JOURNAL OF ENDOVASCULAR THERAPY, 2021, 28 (01) : 53 - 55
  • [8] Pulsed-laser ablation of polytetrafluoroethylene (PTFE) at various wavelengths
    Huber, N
    Heitz, J
    Bäuerle, D
    [J]. EUROPEAN PHYSICAL JOURNAL-APPLIED PHYSICS, 2004, 25 (01) : 33 - 38
  • [9] Natural History of Target Vessel Endoleaks After Fenestrated-Branched Endovascular Aortic Repair
    Jain, Akhilesh K.
    Oderich, Gustavo S.
    Tenorio, Emanuel R.
    Karkkainen, Jussi M.
    Mendes, Bernardo C.
    Macedo, Thanila A.
    Vrtiska, Terri J.
    Gloviczki, Peter
    [J]. JOURNAL OF VASCULAR SURGERY, 2018, 67 (06) : E53 - E54
  • [10] Long-term outcomes of the conformable TAG thoracic endoprosthesis in a prospective multicenter trial
    Jordan, William D.
    Desai, Nimesh
    Letter, Abraham J.
    Matsumura, Jon S.
    [J]. JOURNAL OF VASCULAR SURGERY, 2021, 74 (05) : 1491 - 1498