Full-scale fire resistance tests of lightweight steel framed floor systems

被引:3
作者
Horacek, Martin [1 ]
Gernay, Thomas [2 ]
Karmazinova, Marcela [1 ]
Hladik, Marek [3 ]
Poffel, Zbynek [3 ]
Pesek, Ondrej [1 ]
Balazs, Ivan [1 ]
机构
[1] Brno Univ Technol, Inst Met & Timber Struct, Fac Civil Engn, Veveri St 95-331, Brno 60200, Czech Republic
[2] Johns Hopkins Univ, Whiting Sch Engn, Dept Civil & Syst Engn, 3400 North Charles St, Baltimore, MD 21218 USA
[3] Voestalpine Profilform Sro, Tovarni St 4, Vyskov 68223, Czech Republic
关键词
Cold-formed steel section; Full-scale test; Fire resistance; Lipped channel beam; LSF floor systems; COLD-FORMED STEELS; MECHANICAL-PROPERTIES; BEAMS; TEMPERATURE; SECTIONS; BEHAVIOR;
D O I
10.1016/j.tws.2023.111117
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
As cold-formed steel profiles are increasingly used for load-bearing structural systems, their fire design requires specific attention due to their thin-walled nature and high slenderness. In some specific applications such as in storage hall floor systems, these structures are used without sheathing or thermal protection on the fire-exposed side. Yet, there is a lack of data from fire resistance tests on full-scale load-bearing thin-walled steel structures, especially with directly exposed steel. This article describes two standard fire resistance tests on full-scale light gauge steel frame floors made of cold-formed steel lipped channel girders and joists topped by chipboard panels. The experimental program was designed to investigate the fire resistance of the unprotected girders. A specificity of this program was that the girders were subjected to a low load level to probe the ability to achieve without passive fire protection a 30-min fire resistance rating typical for storage hall structures in the Czech Republic. The absence of protection resulted in differences in thermal gradients and bracing compared to common fire tests, as well as a very low degree of utilization leading to an expected failure temperature higher than 800 degrees C. The results showed that the two floors remained stable during the 30 min with limited deflections, but failed the deflection rate criteria after 24 and 22 min, respectively. Comparison is provided with the calculation methods from the Eurocodes. The presented results provide new data on the response of full-scale, unprotected coldformed steel floor systems subjected to fire, which can be used to calibrate numerical models and fire design methods outside of the range currently covered by the codes.
引用
收藏
页数:19
相关论文
共 34 条
[1]   Behaviour of stud-to-sheathing fastener connections in LSF walls at elevated temperatures [J].
Abeysiriwardena, Tharindu ;
Peiris, Mithum ;
Mahendran, Mahen .
ENGINEERING STRUCTURES, 2021, 238
[2]  
[Anonymous], 2002, 1990 EN
[3]  
[Anonymous], 2020, EN 1363-1:2020-05
[4]  
[Anonymous], 2005, Eurocode 3: Design of Steel Structures, Part 1-2: General Rules - Structural Fire Design
[5]  
[Anonymous], 2005, EN 1993-1-1, DOI DOI 10.1017/CBO9781107415324.004
[6]  
[Anonymous], 2002, EN 1991-1-2
[7]  
[Anonymous], 2014, EN 1365-2 fire resistance tests for loadbearing elements - Part 2: floors and roofs
[8]  
[Anonymous], 2006, EN 1993-1-3
[9]  
[Anonymous], 2006, EN 1993-1-5, Eurocode 3: Design of Steel Structures - Part 1-5: Plated Structural Elements
[10]   Behaviour and resistance of cold-formed steel beams with lipped channel sections under fire conditions [J].
Arrais, Flavio ;
Lopes, Nuno ;
Real, Paulo Vila .
JOURNAL OF STRUCTURAL FIRE ENGINEERING, 2016, 7 (04) :365-387