Full-scale fire resistance tests of lightweight steel framed floor systems

被引:3
|
作者
Horacek, Martin [1 ]
Gernay, Thomas [2 ]
Karmazinova, Marcela [1 ]
Hladik, Marek [3 ]
Poffel, Zbynek [3 ]
Pesek, Ondrej [1 ]
Balazs, Ivan [1 ]
机构
[1] Brno Univ Technol, Inst Met & Timber Struct, Fac Civil Engn, Veveri St 95-331, Brno 60200, Czech Republic
[2] Johns Hopkins Univ, Whiting Sch Engn, Dept Civil & Syst Engn, 3400 North Charles St, Baltimore, MD 21218 USA
[3] Voestalpine Profilform Sro, Tovarni St 4, Vyskov 68223, Czech Republic
关键词
Cold-formed steel section; Full-scale test; Fire resistance; Lipped channel beam; LSF floor systems; COLD-FORMED STEELS; MECHANICAL-PROPERTIES; BEAMS; TEMPERATURE; SECTIONS; BEHAVIOR;
D O I
10.1016/j.tws.2023.111117
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
As cold-formed steel profiles are increasingly used for load-bearing structural systems, their fire design requires specific attention due to their thin-walled nature and high slenderness. In some specific applications such as in storage hall floor systems, these structures are used without sheathing or thermal protection on the fire-exposed side. Yet, there is a lack of data from fire resistance tests on full-scale load-bearing thin-walled steel structures, especially with directly exposed steel. This article describes two standard fire resistance tests on full-scale light gauge steel frame floors made of cold-formed steel lipped channel girders and joists topped by chipboard panels. The experimental program was designed to investigate the fire resistance of the unprotected girders. A specificity of this program was that the girders were subjected to a low load level to probe the ability to achieve without passive fire protection a 30-min fire resistance rating typical for storage hall structures in the Czech Republic. The absence of protection resulted in differences in thermal gradients and bracing compared to common fire tests, as well as a very low degree of utilization leading to an expected failure temperature higher than 800 degrees C. The results showed that the two floors remained stable during the 30 min with limited deflections, but failed the deflection rate criteria after 24 and 22 min, respectively. Comparison is provided with the calculation methods from the Eurocodes. The presented results provide new data on the response of full-scale, unprotected coldformed steel floor systems subjected to fire, which can be used to calibrate numerical models and fire design methods outside of the range currently covered by the codes.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Fire test on floor of full-scale steel-framed structure
    Wang, Yong
    Dong, Yuli
    Peng, Puwei
    Li, Shengshen
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2013, 34 (08): : 1 - 11
  • [2] Experimental study on fire resistance of a full-scale composite floor assembly in a two-story steel framed building
    Choe, Lisa
    Ramesh, Selvarajah
    Dai, Xu
    Hoehler, Matthew
    Bundy, Matthew
    JOURNAL OF STRUCTURAL FIRE ENGINEERING, 2022, 13 (02) : 145 - 161
  • [3] Numerical analysis of full-scale structural fire tests on composite floor systems
    Ma, Chenzhi
    Gernay, Thomas
    FIRE SAFETY JOURNAL, 2024, 146
  • [4] SYSTEMS FOR ANIMAL EXPOSURE IN FULL-SCALE FIRE TESTS
    HILADO, CJ
    CUMMING, HJ
    KOURTIDES, DA
    PARKER, JA
    JOURNAL OF COMBUSTION TOXICOLOGY, 1977, 4 (02): : 101 - 113
  • [5] A fire test of continuous panels in a full-scale steel-framed structure
    Li, Bing
    Dong, Yu-Li
    Lou, Yong-Jie
    Wan, Le
    Gongcheng Lixue/Engineering Mechanics, 2015, 32 (01): : 145 - 153
  • [6] Temperature distribution in a full-scale steel framed building subject to a natural fire
    Wald, F
    Chladná, M
    Moore, D
    Santiago, A
    Lennon, T
    STEEL AND COMPOSITE STRUCTURES, 2006, 6 (02): : 159 - 182
  • [7] Full-scale fire tests on steel roof truss structures
    Jiang, Shouchao
    Zhu, Shaojun
    Guo, Xiaonong
    Li, Zhiyuan
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 169
  • [8] Analysis of full-scale fire tests
    Auguin, G
    Forestier, BE
    Giovannelli, G
    Casalé, E
    10TH INTERNATIONAL SYMPOSIUM ON AERODYNAMICS AND VENTILATION OF VEHICLE TUNNELS: PRINCIPLES, ANALYSIS AND DESIGN, 2000, (43): : 659 - 669
  • [9] Fire tests on two-way concrete, slabs in a full-scale multi-storey steel-framed building
    Yang, Z. N.
    Dong, Y. L.
    Xu, W. J.
    FIRE SAFETY JOURNAL, 2013, 58 : 38 - 48
  • [10] Full-scale fire resistance tests of steel and plasterboard sheathed web-stiffened stud walls
    Dias, Yomal
    Mahendran, Mahen
    Poologanathan, Keerthan
    THIN-WALLED STRUCTURES, 2019, 137 : 81 - 93