Analysis of Voltage Dip Impact on Doubly Fed Induction Generator under Dynamic Conditions

被引:1
作者
Zergaw, Kidist Berhane [1 ]
Tuka, Milkias Berhanu [1 ]
机构
[1] Adama Sci & Technol Univ, Elect Power & Control Engn Dept, Adama, Ethiopia
来源
JORDAN JOURNAL OF ELECTRICAL ENGINEERING | 2023年 / 9卷 / 03期
关键词
Voltage dip; Adaptive neuro-fuzzy inference system; Crowbar; Doubly fed induction generator; Low voltage ride through; CAPABILITY ENHANCEMENT; WIND; DEVICES; RIDE;
D O I
10.5455/jjee.204-1669034454
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Doubly Fed Induction Generator (DFIG) is the most widely employed generator in the Wind Energy Conversion Systems (WECS) for the production of electricity. However, despite all of its various advantages, it is extremely vulnerable to grid faults such as voltage dip since its stator is directly coupled to the grid. A voltage dip problem is one the main issues among the power quality concerns. This fault causes the flow of excessive current across both the stator and the rotor terminals, which may lead to serious damage to the generator, power converters, and DC Link capacitor. On the other hand, the current Grid Codes (GC) requires the system to stay connected to the grid during this fault condition and support it in healing its nominal voltage. This capacity of the system is known as the Low Voltage Ride Through (LVRT) capacity. For the system to achieve such capacity, appropriate protection mechanisms or controlling strategies must be utilized. Therefore, in this paper, the crowbar protection technique, PI controller, and the Adaptive Neuro-Fuzzy Inference System (ANFIS) controller are employed. Furthermore, the performance of the system employing PI, crowbar, and ANFIS is analyzed and compared under grid fault conditions, i.e., a voltage dip with a magnitude of 0.1 pu (worst case) using MATLAB/Simulink software and based on actual data obtained from Adama II wind farm. The obtained results unveil that the settling time of ANFIS for controlling the rotor currents in d and q axes (idr and iqr) and DC link voltage is 3.6 s, 3.57 s, and 3.4 s, respectively. On the other hand, the settling times of the PI controller for controlling the rotor currents in d and q axes and the DC link voltage are found to be 4 s, 3.91 s, and 45.2 s, respectively, while the crowbar protection technique's settling times are found to be 4 s, 6 s, and 4.9 s, respectively. It is evident from the aforesaid results that the ANFIS controller provides the best performance of the three strategies since it allows both the rotor currents and the DC link voltage to return to their steady state values faster than the other two techniques, employed in this investigation.
引用
收藏
页码:338 / 356
页数:19
相关论文
共 50 条
[21]   Investigation of Doubly Fed Induction Generator Behavior Under Symmetrical and Asymmetrical Fault Conditions [J].
Tamvada, Karthik ;
Umashankar, S. ;
Sanjeevikumar, P. .
ADVANCES IN SYSTEMS, CONTROL AND AUTOMATION, 2018, 442 :347-353
[22]   Simulation and Analysis on Low Voltage Ride Through of Doubly-Fed Induction Generator [J].
Shi, Lei ;
Chen, Ning ;
Zhu, Lingzhi ;
Chen, Hu ;
Liu, Haoming .
2011 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2011,
[23]   Overcurrent estimation in a doubly-fed induction generator-DC system during a voltage dip in the dc grid [J].
Marques, Gil ;
Iacchetti, Matteo .
IET RENEWABLE POWER GENERATION, 2016, 10 (07) :1024-1032
[24]   Dynamic modelling of a wind turbine with doubly fed induction generator [J].
Slootweg, JG ;
Polinder, H ;
Kling, WL .
2001 POWER ENGINEERING SOCIETY SUMMER MEETING, VOLS 1-3, CONFERENCE PROCEEDINGS, 2001, :644-649
[25]   Adaptive Backstepping Control of Grid-Connected Doubly-Fed Induction Generator during Grid Voltage Dip [J].
Adekanle, Oluwaseun ;
Guisser, M. ;
Abdelmounim, E. ;
Aboulfatah, M. .
PROCEEDINGS OF 2017 INTERNATIONAL CONFERENCE ON ELECTRICAL AND INFORMATION TECHNOLOGIES (ICEIT 2017), 2017,
[26]   Doubly Fed Induction Generator Low Voltage Ride Through Improvement Through Modular Multilevel Converter [J].
De Souza, Victor Ramon F. B. ;
Barros, Luciano S. ;
Costa, Flavio B. ;
da Silva Junior, Guilherme P. .
IEEE ACCESS, 2022, 10 :57914-57929
[27]   New control scheme for the wind-driven doubly fed induction generator under normal and abnormal grid voltage conditions [J].
Ebrahim, Osama S. ;
Jain, Praveen K. ;
Nishith, Goel .
JOURNAL OF POWER ELECTRONICS, 2008, 8 (01) :10-22
[28]   Dynamic Response of Wind Turbine with Double-Fed Induction Generator during Grid Voltage Dip [J].
Zhang, Kao-she ;
Su, Ping ;
Ning, Lian-hui ;
Zhang, Xin-wei .
2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
[29]   Performance of the Doubly-fed Induction Generator During a Voltage Sag [J].
Taveiros, Filipe E. V. ;
Marques, Max R. ;
Barros, Luciano S. ;
Costa, Flavio B. .
2018 WORKSHOP ON COMMUNICATION NETWORKS AND POWER SYSTEMS (WCNPS), 2018, :79-83
[30]   Dynamic Behavior of the Doubly Fed Induction Generator During Three-phase and Single-phase Voltage Dips [J].
Wu, Yuan-Kang ;
Shu, Wen-Hwa .
2015 4TH INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENTAL PROTECTION (ICEEP 2015), 2015, :1774-1780