Analysis of Voltage Dip Impact on Doubly Fed Induction Generator under Dynamic Conditions

被引:1
|
作者
Zergaw, Kidist Berhane [1 ]
Tuka, Milkias Berhanu [1 ]
机构
[1] Adama Sci & Technol Univ, Elect Power & Control Engn Dept, Adama, Ethiopia
来源
JORDAN JOURNAL OF ELECTRICAL ENGINEERING | 2023年 / 9卷 / 03期
关键词
Voltage dip; Adaptive neuro-fuzzy inference system; Crowbar; Doubly fed induction generator; Low voltage ride through; CAPABILITY ENHANCEMENT; WIND; DEVICES; RIDE;
D O I
10.5455/jjee.204-1669034454
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Doubly Fed Induction Generator (DFIG) is the most widely employed generator in the Wind Energy Conversion Systems (WECS) for the production of electricity. However, despite all of its various advantages, it is extremely vulnerable to grid faults such as voltage dip since its stator is directly coupled to the grid. A voltage dip problem is one the main issues among the power quality concerns. This fault causes the flow of excessive current across both the stator and the rotor terminals, which may lead to serious damage to the generator, power converters, and DC Link capacitor. On the other hand, the current Grid Codes (GC) requires the system to stay connected to the grid during this fault condition and support it in healing its nominal voltage. This capacity of the system is known as the Low Voltage Ride Through (LVRT) capacity. For the system to achieve such capacity, appropriate protection mechanisms or controlling strategies must be utilized. Therefore, in this paper, the crowbar protection technique, PI controller, and the Adaptive Neuro-Fuzzy Inference System (ANFIS) controller are employed. Furthermore, the performance of the system employing PI, crowbar, and ANFIS is analyzed and compared under grid fault conditions, i.e., a voltage dip with a magnitude of 0.1 pu (worst case) using MATLAB/Simulink software and based on actual data obtained from Adama II wind farm. The obtained results unveil that the settling time of ANFIS for controlling the rotor currents in d and q axes (idr and iqr) and DC link voltage is 3.6 s, 3.57 s, and 3.4 s, respectively. On the other hand, the settling times of the PI controller for controlling the rotor currents in d and q axes and the DC link voltage are found to be 4 s, 3.91 s, and 45.2 s, respectively, while the crowbar protection technique's settling times are found to be 4 s, 6 s, and 4.9 s, respectively. It is evident from the aforesaid results that the ANFIS controller provides the best performance of the three strategies since it allows both the rotor currents and the DC link voltage to return to their steady state values faster than the other two techniques, employed in this investigation.
引用
收藏
页码:338 / 356
页数:19
相关论文
共 50 条
  • [1] A Predictive Direct Power Control Applied to the Doubly Fed Induction Generator under Voltage Dip
    de Marchi, Rodrigo A.
    Bim, Edson
    2015 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY (ICIT), 2015, : 2230 - 2235
  • [2] Dynamic Behavior of Doubly Fed Induction Generator during Network Voltage Dips
    Metatla, S.
    Mekhtoub, S.
    Ibtiouen, R.
    Nesba, A.
    2014 INTERNATIONAL CONFERENCE ON ELECTRICAL SCIENCES AND TECHNOLOGIES IN MAGHREB (CISTEM), 2014,
  • [3] Analysis and Calculation of Rotor Currents for Doubly Fed Induction Generator at An Early Stage of Terminal Voltage Dip
    Wang Jian
    Yan Gangui
    Sun Yong
    Zheng Chao
    Shen Qingkun
    PROCEEDINGS OF THE FIRST INTERNATIONAL CONFERENCE ON INFORMATION SCIENCES, MACHINERY, MATERIALS AND ENERGY (ICISMME 2015), 2015, 126 : 2054 - 2058
  • [4] Dynamic phasor modeling of the doubly-fed induction generator under unbalanced conditions
    Demiray, T.
    Milano, F.
    Andersson, G.
    2007 IEEE LAUSANNE POWERTECH, VOLS 1-5, 2007, : 1049 - +
  • [5] Comparative Analysis of the Doubly Fed Induction Generator (DFIG) Under Balanced Voltage Sag
    Osorio, C. M. R.
    Chaves, J. S. S.
    Murari, A. L. L. F.
    Sguarezi Filho, A. J.
    IEEE LATIN AMERICA TRANSACTIONS, 2017, 15 (05) : 869 - 876
  • [6] Voltage-Dip Analysis of Brushless Doubly Fed Induction Generator Using Reduced T-Model
    Sadeghi, Ramtin
    Madani, Seyed M.
    Lipo, Thomas Anthony
    Kashkooli, M. R. Agha
    Ataei, Mohammad
    Ademi, Sul
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2019, 66 (10) : 7510 - 7519
  • [7] Effect of Doubly Fed Induction Generator on Transient Stability Analysis under Fault Conditions
    Soued, S.
    Ramadan, H. S.
    Becherif, M.
    EMERGING AND RENEWABLE ENERGY: GENERATION AND AUTOMATION, 2019, 162 : 315 - 324
  • [8] Direct Power Control Applied to Doubly Fed Induction Generator Under Unbalanced Grid Voltage Conditions
    Santos-Martin, David
    Rodriguez-Amenedo, Jose Luis
    Arnalte, Santiago
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2008, 23 (05) : 2328 - 2336
  • [9] Dynamic behavior of the excitation circuit of a doubly-fed induction generator under a symmetrical voltage drop
    Ouyang, Jinxin
    Xiong, Xiaofu
    RENEWABLE ENERGY, 2014, 71 : 629 - 638
  • [10] Dynamic Characteristic Analysis of Doubly-fed Induction Generator Low Voltage Ride-through
    Shi, L.
    Chen, N.
    Lu, Q.
    2012 INTERNATIONAL CONFERENCE ON FUTURE ENERGY, ENVIRONMENT, AND MATERIALS, PT C, 2012, 16 : 1526 - 1534