Closed-Loop FES Control of a Hybrid Exoskeleton during Sit-to-Stand Exercises: Concept and First Evaluation

被引:1
|
作者
Lyu, Chenglin [1 ]
Morim, Pedro Truppel [1 ]
Penzlin, Bernhard [1 ,2 ]
Roehren, Felix [1 ]
Bergmann, Lukas [1 ]
von Platen, Philip [1 ]
Bollheimer, Cornelius [3 ]
Leonhardt, Steffen [1 ]
Ngo, Chuong [1 ]
机构
[1] Rhein Westfal TH Aachen, Helmholtz Inst Biomed Engn, Chair Med Informat Technol, Pauwelsstr 20, D-52074 Aachen, Germany
[2] EXYTRON GmbH, Kurt Dunkelmann Str 5, D-18057 Rostock, Germany
[3] RWTH Aachen Univ Hosp, Fac Med, Dept Geriatr Med, Morillenhang 27, D-52074 Aachen, Germany
关键词
functional electrical stimulation (FES); exoskeleton; hybrid control; body motion capture; FUNCTIONAL ELECTRICAL-STIMULATION; ORIENTATION IN-SPACE; MOVEMENT; POSITION; PATIENT; WALKING; BONES;
D O I
10.3390/act12080316
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Rehabilitation of paralysis caused by a stroke or a spinal cord injury remains a complex and time-consuming task. This work proposes a hybrid exoskeleton approach combining a traditional exoskeleton and functional electrical stimulation (FES) as a promising method in rehabilitation. However, hybrid exoskeletons with a closed-loop FES control strategy are functionally challenging to achieve and have not been reported often. Therefore, this study aimed to investigate a powered lower-limb exoskeleton with a closed-loop FES control for Sit-to-Stand (STS) movements. A body motion capture system was applied to record precise hip and knee trajectories of references for establishing the human model. A closed-loop control strategy with allocation factors is proposed featuring a two-layer cascaded proportional-integral-derivative (PID) controller for both FES and exoskeleton control. Experiments were performed on two participants to examine the feasibility of the hybrid exoskeleton and the closed-loop FES control. Both open-and closed-loop FES control showed the desired performance with a relatively low root-mean-squared error (max 1.3 degrees in open-loop and max 4.1 degrees in closed-loop) in hip and knee trajectories. Notably, the closed-loop FES control strategy can achieve the same performance with nearly 60% of the electrical power input compared to the open-loop control, which reduced muscle fatigue and improved robustness during the training. This study provides novel insights into body motion capture application and proposes a closed-loop FES control for hybrid exoskeletons.
引用
收藏
页数:18
相关论文
共 34 条
  • [1] Hybrid FES-Exoskeleton Controller to Assist Sit-To-Stand movement
    Alouane, Mohamed Amine
    Huo, Weiguang
    Rifai, Hala
    Amirat, Yacine
    Mohammed, Samer
    IFAC PAPERSONLINE, 2019, 51 (34): : 296 - 301
  • [2] HYBRID FES ORTHOSIS INCORPORATING CLOSED-LOOP CONTROL AND SENSORY FEEDBACK
    ANDREWS, BJ
    BAXENDALE, RH
    BARNETT, R
    PHILLIPS, GF
    YAMAZAKI, T
    PAUL, JP
    FREEMAN, PA
    JOURNAL OF BIOMEDICAL ENGINEERING, 1988, 10 (02): : 189 - 195
  • [3] An Iterative Learning Controller for a Switched Cooperative Allocation Strategy During Sit-to-Stand Tasks with a Hybrid Exoskeleton
    Molazadeh, Vahidreza
    Zhang, Qiang
    Bao, Xuefeng
    Sharma, Nitin
    IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2022, 30 (03) : 1021 - 1036
  • [4] Closed-Loop Torque and Kinematic Control of a Hybrid Lower-Limb Exoskeleton for Treadmill Walking
    Chang, Chen-Hao
    Casas, Jonathan
    Brose, Steven W.
    Duenas, Victor H.
    FRONTIERS IN ROBOTICS AND AI, 2022, 8
  • [5] Evaluation criterion and closed-loop control of penetration status during laser-MIG hybrid welding
    Zhang, Yongqiang
    Wen, Peng
    Shan, Jiguo
    Shuang, Yuanqing
    Chen, Wuzhu
    JOURNAL OF LASER APPLICATIONS, 2010, 22 (03) : 92 - 98
  • [6] Bolusing frequency and amount impacts glucose control during hybrid closed-loop
    Bally, L.
    Thabit, H.
    Ruan, Y.
    Mader, J. K.
    Kojzar, H.
    Dellweg, S.
    Benesch, C.
    Hartnell, S.
    Leelarathna, L.
    Wilinska, M. E.
    Evans, M. L.
    Arnolds, S.
    Pieber, T. R.
    Hovorka, R.
    DIABETIC MEDICINE, 2018, 35 (03) : 347 - 351
  • [7] Closed-Loop Feedback Control of Human Step Width During Walking by Mediolaterally Acting Robotic Hip Exoskeleton
    Alili, Abbas
    Nalam, Varun
    Fleming, Aaron
    Liu, Ming
    Dean, Jesse
    Huang, Helen
    2023 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS (IROS), 2023, : 6097 - 6102
  • [8] GLUCOSE CONTROL IN ADOLESCENTS WITH T1D DURING THE MEDTRONIC HYBRID CLOSED-LOOP PIVOTAL TRIAL
    Sherr, Jennifer
    Weinzimer, Stuart A.
    Slover, Robert H.
    Buckingham, Bruce A.
    Criego, Amy B.
    Anderson, Stacey M.
    Bailey, Timothy S.
    Bode, Bruce W.
    Brazg, Ronald L.
    Garg, Satish K.
    Ilany, Jacob
    Shin, John
    Lee, Scott W.
    Cordero, Toni
    Kaufman, Francine R.
    HORMONE RESEARCH IN PAEDIATRICS, 2017, 88 : 46 - 47
  • [9] Use of Advanced Hybrid Closed-Loop System during Pregnancy: Strengths and Limitations of Achieving a Tight Glycemic Control
    Giannoulaki, Parthena
    Kotzakioulafi, Evangelia
    Nakas, Alexandros
    Kontoninas, Zisis
    Evripidou, Polykarpos
    Didangelos, Triantafyllos
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (05)
  • [10] EVALUATION OF CLOSED-LOOP CONTROL OF ARTERIAL-PRESSURE DURING HYPOTENSIVE ANESTHESIA FOR LOCAL RESECTION OF INTRAOCULAR MELANOMA
    CHAUDHRI, S
    COLVIN, JR
    TODD, JG
    KENNY, GNC
    BRITISH JOURNAL OF ANAESTHESIA, 1992, 69 (06) : 607 - 610