Benchmarking halcyon ring delivery system for hypofractionated breast radiotherapy: Validation and clinical implementation of the fast-forward trial

被引:0
|
作者
Pokhrel, Damodar [1 ,2 ]
Smith, Mason [1 ]
Volk, Alexander [1 ]
Bernard, Mark E. [1 ]
机构
[1] Univ Kentucky, Dept Radiat Med, Lexington, KY USA
[2] Univ Kentucky, Dept Radiat Med, Med Phys Grad Program, Lexington, KY 40506 USA
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2023年 / 24卷 / 09期
关键词
AcurosXB algorithm; APBI-VMAT; Co-planar geometry; Fast-Forward trial; Halcyon RDS; DOSE CALCULATION; CANCER; LINAC;
D O I
10.1002/acm2.14047
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeThe aim of this study was to demonstrate the feasibility and efficacy of an iterative CBCT-guided breast radiotherapy with Fast-Forward trial of 26 Gy in five fractions on a Halcyon Linac. This study quantifies Halcyon plan quality, treatment delivery accuracy and efficacy by comparison with those of clinical TrueBeam plans. Materials and MethodsTen accelerated partial breast irradiation (APBI) patients (four right, six left) who underwent Fast-Forward trial at our institute on TrueBeam (6MV beam) were re-planned on Halcyon (6MV-FFF). Three site-specific partial coplanar VMAT arcs and an Acuros-based dose engine were used. For benchmarking, PTV coverage, organs-at-risk (OAR) doses, beam-on time, and quality assurance (QA) results were compared for both plans. ResultsThe average PTV was 806 cc. Compared to TrueBeam plans, Halcyon provided highly conformal and homogeneous plans with similar mean PTVD95 (25.72 vs. 25.73 Gy), both global maximum hotspot < 110% (p = 0.954) and similar mean GTV dose (27.04 vs. 26.80 Gy, p = 0.093). Halcyon provided lower volume of ipsilateral lung receiving 8 Gy (6.34% vs. 8.18%, p = 0.021), similar heart V1.5 Gy (16.75% vs. 16.92%, p = 0.872), V7Gy (0% vs. 0%), mean heart dose (0.96 vs. 0.9 Gy, p = 0.228), lower maximum dose to contralateral breast (3.2 vs. 3.6 Gy, p = 0.174), and nipple (19.6 vs. 20.1 Gy, p = 0.363). Compared to TrueBeam, Halcyon plans provided similar patient-specific QA pass rates and independent in-house Monte Carlo second check results of 99.6% vs. 97.9% (3%/2 mm gamma criteria) and 98.6% versus 99.2%, respectively, suggesting similar treatment delivery accuracy. Halcyon provided shorter beam-on time (1.49 vs. 1.68 min, p = 0.036). ConclusionCompared to the SBRT-dedicated TrueBeam, Halcyon VMAT plans provided similar plan quality and treatment delivery accuracy, yet potentially faster treatment via one-step patient setup and verification with no patient collision issues. Rapid delivery of daily APBI on Fast-Forward trial on Halcyon with door-to-door patient time < 10 min, could reduce intrafraction motion errors, and improve patient comfort and compliance. We have started treating APBI on Halcyon. Clinical follow-up results are warranted. We recommend Halcyon users consider implementing the protocol to remote and underserved APBI patients in Halcyon-only clinics.
引用
收藏
页数:8
相关论文
共 3 条
  • [1] Ultrahypofractionated breast radiotherapy during SARS-CoV-2 virus pandemic, beyond fast-forward trial: a local experience
    Yahya, Sundus
    Fatima, Tamseel
    Irwin, Amy Louise
    Clayton, Melanie
    Spooner, David
    Fernando, Indrajit
    Stevens, Andrea
    Sherriff, Jenny
    Henderson, Daniel
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2022, 22
  • [2] Delivery of a VMAT technique with flattening filter (FF) and flattening filter free (FFF) mode for whole breast irradiation with five fractions (FAST-Forward trial)
    Akhtaruzzaman, Md
    Islam, Md Jobairul
    Mannan, Md Abdul
    Sumon, Mostafa Aziz
    Ebert, Martin
    MEDICAL DOSIMETRY, 2023, 48 (04) : 211 - 215
  • [3] Hypofractionated breast radiotherapy for 1 week versus 3 weeks (FAST-Forward): 5-year efficacy and late normal tissue effects results from a multicentre, non-inferiority, randomised, phase 3 trial
    Brunt, Adrian Murray
    Haviland, Joanne S.
    Wheatley, Duncan A.
    Sydenham, Mark A.
    Alhasso, Abdulla
    Bloomfield, David J.
    Chan, Charlie
    Churn, Mark
    Cleator, Susan
    Coles, Charlotte E.
    Goodman, Andrew
    Harnett, Adrian
    Hopwood, Penelope
    Kirby, Anna M.
    Kirwan, Cliona C.
    Morris, Carolyn
    Nabi, Zohal
    Sawyer, Elinor
    Somaiah, Navita
    Stones, Liba
    Syndikus, Isabel
    Bliss, Judith M.
    Yarnold, John R.
    LANCET, 2020, 395 (10237) : 1613 - 1626