Implementation of triggered kilovoltage imaging for stereotactic radiotherapy of the spine for patients with spinal fixation hardware

被引:3
|
作者
Cetnar, Ashley J. [1 ,2 ,3 ]
Degnan, Michael [1 ,2 ]
Pichler, Joseph [1 ,2 ]
Jain, Sagarika [1 ,2 ]
Morelli, Samantha [1 ,2 ]
Thomas, Evan [1 ,2 ]
Elder, J. Bradley [1 ,2 ]
Scharschmidt, Thomas J. [1 ,2 ]
Palmer, Joshua D. [1 ,2 ]
Blakaj, Dukagjin M. [1 ,2 ]
机构
[1] Ohio State Univ, James Canc Hosp, 460 W 10th Ave, Columbus, OH 43210 USA
[2] Ohio State Univ, Solove Res Inst, Dept Radiat Oncol, 460 W 10th Ave, Columbus, OH 43210 USA
[3] Dept Radiat Oncol, A201 Off F,460 W 10th Ave, Columbus, OH 43210 USA
来源
PHYSICS & IMAGING IN RADIATION ONCOLOGY | 2023年 / 25卷
关键词
Intrafraction motion review; Triggered imaging; Advanced imaging; Spine; Stereotactic; BODY RADIATION-THERAPY; INTRAFRACTION MOTION; CONSENSUS GUIDELINES; RESPIRATORY MOTION; METASTASES; PROSTATE; RADIOSURGERY; MANAGEMENT; CANCER; CORD;
D O I
10.1016/j.phro.2023.100422
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Mitigation of intrafraction motion (IM) is valuable in stereotactic radiotherapy (SRT) radiotherapy where submillimeter accuracy is desired. The purpose of this study was to investigate the application of triggered kilovoltage (kV) imaging for spine SRT patients with hardware by correlating kV imaging with patient motion and summarizing implications of tolerance for IM based on calculated dose.Materials and methods: Ten plans (33 fractions) were studied, correlating kV imaging during treatment with preand post-treatment cone beam computed tomography (CBCT). Images were taken at 20-degree gantry angle intervals during the arc-based treatment. The contour of the hardware with a 1 mm expansion was displayed at the treatment console to manually pause treatment delivery if the hardware was visually detected outside the contour. The treatment CBCTs were compared using retrospective image registration to assess the validity of contour-based method for pausing treatment. Finally, plans were generated to estimate dose volume objective differences in case of 1 mm deviation.Results: When kV imaging during treatment was used with the 1 mm contour, 100 % of the post-treatment CBCTs reported consistent results. One patient in the cohort exhibited motion greater than 1 mm during treatment which allowed intervention and re-setup during treatment. The average translational motion was 0.35 mm. Treatment plan comparison at 1 mm deviation showed little differences in calculated dose for the target and cord.Conclusions: Utilizing kV imaging during treatment is an effective method of assessing IM for SRT spine patients with hardware without increasing treatment time.
引用
收藏
页数:5
相关论文
共 45 条
  • [21] Vertebral Compression Fracture After Spine Stereotactic Body Radiotherapy: A Multi-Institutional Analysis With a Focus on Radiation Dose and the Spinal Instability Neoplastic Score
    Sahgal, Arjun
    Atenafu, Eshetu G.
    Chao, Sam
    Al-Omair, Ameen
    Boehling, Nicholas
    Balagamwala, Ehsan H.
    Cunha, Marcelo
    Thibault, Isabelle
    Angelov, Lilyana
    Brown, Paul
    Suh, John
    Rhines, Laurence D.
    Fehlings, Michael G.
    Chang, Eric
    JOURNAL OF CLINICAL ONCOLOGY, 2013, 31 (27) : 3426 - 3431
  • [22] Monte Carlo calculation of dose distributions in oligometastatic patients planned for spine stereotactic ablative radiotherapy
    Moiseenko, V.
    Liu, M.
    Loewen, S.
    Kosztyla, R.
    Vollans, E.
    Lucido, J.
    Fong, M.
    Vellani, R.
    Popescu, I. A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (20) : 7107 - 7116
  • [23] Randomized phase II trial evaluating pain response in patients with spinal metastases following stereotactic body radiotherapy versus three-dimensional conformal radiotherapy
    Sprave, Tanja
    Verma, Vivek
    Foerster, Robert
    Schlampp, Ingmar
    Bruckner, Thomas
    Bostel, Tilman
    Welte, Stefan Ezechiel
    Tonndorf-Martini, Eric
    Nicolay, Nils Henrik
    Debus, Juergen
    Rief, Harald
    RADIOTHERAPY AND ONCOLOGY, 2018, 128 (02) : 274 - 282
  • [24] Hypofractionated stereotactic radiotherapy alone without whole-brain irradiation for patients with solitary and oligo brain metastasis using noninvasive fixation of the skull
    Aoyama, HI
    Shirato, H
    Onimaru, R
    Kagei, K
    Ikeda, J
    Ishii, N
    Sawamura, Y
    Miyasaka, K
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (03): : 793 - 800
  • [25] Comparison of Clinical Outcomes Stratified by Target Delineation for Patients Undergoing Stereotactic Body Radiotherapy for Spinal Metastases
    Attiah, Mark
    Sandler, Kiri
    Medina, Rogelio
    Gaonkar, Bilwaj
    McArthur, David
    Farha, George
    Selch, Michael
    De Salles, Antonio
    Tenn, Stephen
    Agazaryan, Nzhde
    Lee, Percy
    Steinberg, Michael
    Lu, Daniel
    Macyszyn, Luke
    Kaprealian, Tania
    WORLD NEUROSURGERY, 2020, 136 : E68 - E74
  • [26] Oligometastatic Disease State Is Associated with Improved Local Control in Patients Undergoing Three or Five Fraction Spine Stereotactic Body Radiotherapy
    Silva, Scott R.
    Gliniewicz, Adam
    Martin, Brendan
    Prabhu, Vikram C.
    Germanwala, Anand V.
    Melian, Edward
    Jones, G. Alex
    Solanki, Abhishek A.
    WORLD NEUROSURGERY, 2019, 122 : E342 - E348
  • [27] RECURSIVE PARTITIONING ANALYSIS INDEX IS PREDICTIVE FOR OVERALL SURVIVAL IN PATIENTS UNDERGOING SPINE STEREOTACTIC BODY RADIATION THERAPY FOR SPINAL METASTASES
    Chao, Samuel T.
    Koyfman, Shlomo A.
    Woody, Neil
    Angelov, Lilyana
    Soeder, Sherry L.
    Reddy, Chandana A.
    Rybicki, Lisa A.
    Djemil, Toufik
    Suh, John H.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 82 (05): : 1738 - 1743
  • [28] Quantification of six-degree-of-freedom motion during beam delivery in spine stereotactic body radiotherapy using intra-irradiation cone-beam computed tomography imaging technique
    Iramina, Hiraku
    Nakamura, Mitsuhiro
    Nakamura, Kiyonao
    Fujimoto, Takahiro
    Mizowaki, Takashi
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 110
  • [29] Feasibility of spine stereotactic body radiotherapy for patients with large tumors in multiple vertebrae undergoing re-irradiation: Dosimetric challenge using 3 different beam delivery techniques
    Furuya, Tomohisa
    Phua, Jun H.
    Ito, Kei
    Karasawa, Katsuyuki
    MEDICAL DOSIMETRY, 2019, 44 (04) : 415 - 420
  • [30] Effects of combined adjustable Halo-pelvic fixation brace on cervical spine alignment in patients with severe rigid spinal deformity
    Rong, Zhigang
    Zhang, Chengmin
    Cheng, Peng
    Dai, Fei
    Chen, Can
    Yu, Xueke
    Xu, Jianzhong
    Luo, Fei
    BMC SURGERY, 2022, 22 (01)