Diagnostic Performance of Prototype Handheld Ultrasound According to the Fifth Edition of BI-RADS for Breast Ultrasound Compared with Automated Breast Ultrasound among Females with Positive Lumps

被引:1
作者
Ibraheem, Shahad A. [1 ]
Mahmud, Rozi [1 ,2 ]
Mohamad Saini, Suraini [1 ,2 ]
Abu Hassan, Hasyma [1 ]
Keiteb, Aysar Sabah [3 ]
机构
[1] Univ Putra Malaysia, Fac Med & Hlth Sci, Dept Radiol, Serdang 43400, Selangor, Malaysia
[2] Univ Putra Malaysia, Ctr Diagnost Nucl Imaging, Serdang 43400, Selangor, Malaysia
[3] Coll Hlth & Med Technol, Dept Radiol Tech, Baghdad 10047, Iraq
关键词
prototype handheld ultrasound; BI-RADS; ABUS; breast cancer; HHUS; VOLUME SCANNER; INTEROBSERVER AGREEMENT; DIFFERENTIATING BENIGN; IMAGING FEATURES; LESIONS; CANCER; ABUS; US; MAMMOGRAPHY; IMPROVEMENT;
D O I
10.3390/diagnostics13061065
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
(1) Objective: To evaluate the diagnostic performance of prototype handheld ultrasound compared to automated breast ultrasound, according to the fifth edition of BI-RADS categorization, among females with positive lumps. (2) Methods: A total of 1004 lesions in 162 participants who underwent both prototype handheld ultrasound and automated breast ultrasound were included. Two radiologists and a sonographer independently evaluated the sonographic features of each lesion according to the fifth BI-RADS edition. The kappa coefficient (kappa) was calculated for each BI-RADS descriptor and final assessment category. The cross-tabulation was performed to see whether there were differences between the ABUS and prototype HHUS results. Specificity and sensitivity were evaluated and compared using the McNamar test. (3) Results: ABUS and prototype HHUS observers found the same number of breast lesions in the 324 breasts of the 162 respondents. There was no significant difference in the mean lesion size, with a maximum mean length dimension of 0.48 +/- 0.33 cm. The assessment of the lesion's shape, orientation, margin, echo pattern, posterior acoustic features, and calcification was obtained with good to excellent agreements between ABUS and prototype HHUS observers (kappa = 0.70-1.0). There was absolutely no significant difference between ABUS and prototype HHUS in assessment of lesion except for lesion orientation p = 0.00. Diagnostic accuracy (99.8% and 97.7-98.9%), sensitivity (99.5% and 98.0-99.0%), specificity (99.8% and 99.6-99.8%), positive predictive value (98.1% and 90.3-96.2%), negative predictive value (90.0% and 84.4-88.7%), and areas under the curve (0.98 and 0.83-0.92; p < 0.05) were not significantly different between ABUS and prototype HHUS observers. (4) Conclusion: According to the fifth BI-RADS edition, automated breast ultrasound is not statistically significantly different from prototype handheld ultrasound with regard to interobserver variability and diagnostic performance.
引用
收藏
页数:21
相关论文
共 38 条
[1]   Breast Imaging Reporting and Data System Lexicon for US: Interobserver Agreement for Assessment of Breast Masses [J].
Abdullah, Nouf ;
Mesurolle, Benoit ;
El-Khoury, Mona ;
Kao, Ellen .
RADIOLOGY, 2009, 252 (03) :665-672
[2]  
[Anonymous], 2017, Singapore Cancer Registry Annual Registry Report 2015
[3]  
Azizah AM, 2019, Malaysia national cancer registry report 2012-2016
[4]   Agreement Between an Automated Volume Breast Scanner and Handheld Ultrasound for Diagnostic Breast Examinations [J].
Barr, Richard G. ;
DeVita, Robert ;
Destounis, Stamatia ;
Manzoni, Federica ;
De Silvestri, Annalisa ;
Tinelli, Carmine .
JOURNAL OF ULTRASOUND IN MEDICINE, 2017, 36 (10) :2087-2092
[5]   Assessing Improvement in Detection of Breast Cancer with Three-dimensional Automated Breast US in Women with Dense Breast Tissue: The Somoinsight Study [J].
Brem, Rachel F. ;
Tabar, Laszlo ;
Duffy, Stephen W. ;
Inciardi, Marc F. ;
Guingrich, Jessica A. ;
Hashimoto, Beverly E. ;
Lander, Marla R. ;
Lapidus, Robert L. ;
Peterson, Mary Kay ;
Rapelyea, Jocelyn A. ;
Roux, Susan ;
Schilling, Kathy J. ;
Shah, Biren A. ;
Torrente, Jessica ;
Wynn, Ralph T. ;
Miller, Dave P. .
RADIOLOGY, 2015, 274 (03) :663-673
[6]   DIAGNOSTIC PERFORMANCE OF AUTOMATED BREAST ULTRASOUND AS A REPLACEMENT FOR A HAND-HELD SECOND-LOOK ULTRASOUND FOR BREAST LESIONS DETECTED INITIALLY ON MAGNETIC RESONANCE IMAGING [J].
Chae, Eun Young ;
Shin, Hee Jung ;
Kim, Hyun Ji ;
Yoo, Hyunkyung ;
Baek, Seunghee ;
Cha, Joo Hee ;
Kim, Hak Hee .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (12) :2246-2254
[7]   Automated breast ultrasound system (ABUS): reproducibility of mass localization, size measurement, and characterization on serial examinations [J].
Chang, Jung Min ;
Cha, Joo Hee ;
Park, Jeong Seon ;
Kim, Seung Ja ;
Moon, Woo Kyung .
ACTA RADIOLOGICA, 2015, 56 (10) :1163-1170
[8]   Dependability of Automated Breast Ultrasound (ABUS) in Assessing Breast Imaging Reporting and Data System (BI-RADS) Category and Size of Malignant Breast Lesions Compared with Handheld Ultrasound (HHUS) and Mammography (MG) [J].
Chen, He ;
Han, Ming ;
Jing, Hui ;
Liu, Zhao ;
Shang, Haitao ;
Wang, Qiucheng ;
Cheng, Wen .
INTERNATIONAL JOURNAL OF GENERAL MEDICINE, 2021, 14 :9193-9202
[9]   COMPARATIVE STUDY OF AUTOMATED BREAST 3-D ULTRASOUND AND HANDHELD B-MODE ULTRASOUND FOR DIFFERENTIATION OF BENIGN AND MALIGNANT BREAST MASSES [J].
Chen, Lin ;
Chen, Yue ;
Diao, Xue-Hong ;
Fang, Liang ;
Pang, Yun ;
Cheng, Ai-Qun ;
Li, Wei-Ping ;
Wang, Yi .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (10) :1735-1742
[10]   Automated breast cancer detection and classification using ultrasound images: A survey [J].
Cheng, H. D. ;
Shan, Juan ;
Ju, Wen ;
Guo, Yanhui ;
Zhang, Ling .
PATTERN RECOGNITION, 2010, 43 (01) :299-317