The influence of corneal tunnel length on surgically induced astigmatism after various types of microincision phacoemulsification

被引:1
|
作者
Wilczynski, Michal [1 ,2 ]
Kucharczyk-Pospiech, Magdalena [1 ]
Omulecki, Wojciech [1 ]
机构
[1] Med Univ Lodz, Dept Ophthalmol, Lodz, Poland
[2] Med Univ Lodz, Univ Barlicki Hosp, Dept Ophthalmol, 1 Ul Kopcinskiego 22, PL-90153 Lodz, Poland
关键词
Phacoemulsification; MICS; astigmatism; SIA; OCT; tunnel length; VIVO ARCHITECTURAL ANALYSIS; INCISIONS;
D O I
10.1177/11206721231160387
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To evaluate the influence of the corneal tunnel length on surgically induced astigmatism (SIA) after 3 phacoemulsification techniques. Methods Patients who underwent a planned phacoemulsification surgery with an implantation of a foldable, acrylic IOL were selected for the study. All surgeries were performed under topical anaesthesia, with the same phaco machine. Group I consisted of 30 eyes of 30 patients after bimanual 1.4 mm microincision cataract surgery (B-MICS). Group II consisted of 30 eyes of 30 patients after coaxial 1.8 mm microincision cataract surgery (C-MICS). Group III consisted of 30 eyes of 30 patients after coaxial 2.4 mm small incision cataract surgery (C-SICS). Best corrected visual acuity, autorefractometry, tonometry, a slit lamp examination and anterior segment OCT were performed preoperatively and 1, 7, 30 and 90 days postoperatively. The temporal peripheral corneal thickness and the chord length of the main incision were measured. Vector method was used to calculate SIA. Results Mean preoperative BCVA was 0.52 +/- 0.19 and it improved to 0.98 +/- 0.05 (p < 0.05). Mean corneal tunnel chord length was 1.30 +/- 0.16 mm 90 days postoperatively in group I, 1.30 +/- 0.19 mm in group II and 1.48 +/- 0.22 mm in group III. SIA was 0.54 +/- 0.48 mm in group I, 0.45 +/- 0.21 mm in group II and 0.62 +/- 0.30 mm in group III. There were no correlations between the chord length of the corneal tunnel and SIA calculated with using vector analysis method. Conclusions Unlike the incision width, the length of the clear corneal tunnel in small incisions and microinicions, has no significant influence on SIA.
引用
收藏
页码:1939 / 1945
页数:7
相关论文
共 50 条
  • [41] Surgically Induced Astigmatism after Cataract Surgery - A Vector Analysis
    Langenbucher, Achim
    Szentmary, Nora
    Cayless, Alan
    Casaza, Marina
    Weisensee, Johannes
    Hoffmann, Peter
    Wendelstein, Jascha
    CURRENT EYE RESEARCH, 2022, 47 (09) : 1279 - 1287
  • [42] Changes of corneal astigmatism and axial length induced by scleral buckling surgery
    Grimm, G
    Aust, W
    Stark, M
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1997, 210 (03) : 144 - 146
  • [43] Influence of suture regularity on corneal astigmatism after penetrating keratoplasty
    Hjortdal, Jesper
    Sondergaard, Anders
    Fledelius, Walther
    Ehlers, Niels
    ACTA OPHTHALMOLOGICA, 2011, 89 (05) : 412 - 416
  • [44] SURGICALLY INDUCED ASTIGMATISM AFTER UPPER EYELID SURGERY IN ADULT PATIENTS
    Altinkurt, Emre
    Aksu Ceylan, Nihan
    JOURNAL OF ISTANBUL FACULTY OF MEDICINE-ISTANBUL TIP FAKULTESI DERGISI, 2020, 83 (03): : 193 - 196
  • [45] Prediction of surgically induced astigmatism in manual and femtosecond laser-assisted clear corneal incisions
    Fernandez, Joaquin
    Rodriguez-Vallejo, Manuel
    Martinez, Javier
    Tauste, Ana
    Pinero, David P.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2018, 28 (04) : 398 - 405
  • [46] Surgically induced astigmatism in canines following sutured dorsonasal vs dorsotemporal clear corneal incisions
    Pederson, Samantha L.
    Cleymaet, Allison M.
    Hess, Ann M.
    Wotman, Kathryn L.
    Freeman, Kate S.
    VETERINARY OPHTHALMOLOGY, 2019, 22 (06) : 799 - 806
  • [47] REDUCTION OF SURGICALLY INDUCED CORNEAL ASTIGMATISM FOLLOWING SUTURE DISSECTION BY ARGON-LASER APPLICATION
    GIERS, U
    PILLUNAT, LE
    OPHTHALMOLOGICA, 1991, 202 (03) : 117 - 124
  • [48] Comparison of surgically induced astigmatism in various incisions in manual small incision cataract surgery
    Nidhi Jauhari
    Deepak Chopra
    Rajan Kumar Chaurasia
    Ashutosh Agarwal
    International Journal of Ophthalmology, 2014, (06) : 1001 - 1004
  • [49] Surgically induced astigmatism after posterior chamber phakic intraocular lens implantation
    Kamiya, K.
    Shimizu, K.
    Aizawa, D.
    Igarashi, A.
    Komatsu, M.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2009, 93 (12) : 1648 - 1651
  • [50] SURGICALLY INDUCED ASTIGMATISM IN 2.8 MM, 5.3 MM PHACOEMULSIFICATION AND 6.0 MM MANUAL SMALL INCISION CATARACT SURGERY
    Gupta, Ankur
    Arora, Indu
    Kumar, Dileep
    Gupta, Daya Chand
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2014, 3 (19): : 5283 - 5290