Accuracy of a Patient-Specific Total Ankle Arthroplasty Instrumentation

被引:5
作者
April, Pierre-Marc [1 ]
Locke, Eric [1 ]
Champagne, Philippe-Hugo [2 ]
Angers, Magalie [2 ]
Martinez-Gomez, Adriana Patricia [1 ]
Seidel, Angela [1 ]
Jibri, Zaid [1 ]
Lalonde, Karl-Andre [1 ]
Meulenkamp, Brad [1 ]
机构
[1] Civ Hosp, Dept Orthopaed, Ottawa, ON, Canada
[2] CHUS, Dept Orthopaed, Sherbrooke, PQ, Canada
关键词
foot and ankle surgery; total ankle arthroplasty; patient specific instrumentation; alignment outcomes; END-STAGE ANKLE; LONG-TERM OUTCOMES; REPLACEMENT; ARTHRODESIS; INTERMEDIATE; SURVIVORSHIP; MISALIGNMENT; ALIGNMENT; SERIES;
D O I
10.1177/10711007231194049
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Total ankle arthroplasty (TAA) is a preferred surgical option for end-stage ankle osteoarthritis; however, it is a demanding procedure with a higher historical rate of revision compared with ankle fusion. Patient-specific instrumentation (PSI) has been introduced to optimize prosthesis alignment and theoretically overall improve TAA outcomes. The goal of this study is to report on the experience and surgical outcomes of one implant with specific evaluation of the accuracy and reproducibility of the system with respect to prosthesis alignment and prediction of implant size. Methods: A retrospective, multicentered study involving 4 foot and ankle fellowship-trained orthopaedic surgeon's patients undergoing TAA between January 1, 2015, and December 31, 2018, using the PROPHECY PSI system. Results: 80 TAA procedures were performed. On average the postoperative tibial component alignment was 89.9 (range, 86.1-96.5) degrees in the coronal plane, with a mean sagittal alignment of 88.1 (range, 81.3-96.7) degrees. The mean deviation from neutral sagittal alignment improved from 4.9 +/- 3.9 degrees preoperatively to 2.7 +/- 1.7 degrees postoperatively, whereas the mean coronal alignment improved from 3.3 +/- 2.5 degrees to 1.3 +/- 1.1 degrees. The PSI software correctly determined the tibial implant size in 70 patients (89%). Prediction of talar implant sizing was less accurate than the tibial component, with 56 patients (71%) using the predicted sized implant. The overall implant survival at a mean follow-up of 45 months (range, 27-76) was 97.5%. Conclusion: We found that this PSI system accurately and reliably assisted in implant total ankle prosthesis positioning within a clinically acceptable margin and without significant outliers. Prediction of implant size was not as accurate as component orientation. Level of Evidence: Level III, retrospective study.
引用
收藏
页码:1150 / 1157
页数:8
相关论文
共 41 条
[1]   Comparison of Extramedullary Versus Intramedullary Referencing for Tibial Component Alignment in Total Ankle Arthroplasty [J].
Adams, Samuel B., Jr. ;
Demetracopoulos, Constantine A. ;
Viens, Nicholas A. ;
DeOrio, James K. ;
Easley, Mark E. ;
Queen, Robin M. ;
Nunley, James A., II .
FOOT & ANKLE INTERNATIONAL, 2013, 34 (12) :1624-1628
[2]   Peri-prosthetic bone cysts after total ankle replacement. A systematic review and meta-analysis [J].
Arcangelo, Joana ;
Guerra-Pinto, Francisco ;
Pinto, Andre ;
Grenho, Andre ;
Navarro, Alfons ;
Martin Oliva, Xavier .
FOOT AND ANKLE SURGERY, 2019, 25 (02) :96-105
[3]  
Ast Michael P, 2012, Orthop Clin North Am, V43, pe17, DOI 10.1016/j.ocl.2012.07.004
[4]   HINTEGRA Total Ankle Replacement: Survivorship Analysis in 684 Patients [J].
Barg, Alexej ;
Zwicky, Lukas ;
Knupp, Markus ;
Henninger, Heath B. ;
Hintermann, Beat .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2013, 95A (13) :1175-1183
[5]   The Effect of Three-Component Total Ankle Replacement Malalignment on Clinical Outcome: Pain Relief and Functional Outcome in 317 Consecutive Patients [J].
Barg, Alexej ;
Elsner, Andreas ;
Anderson, Andrew E. ;
Hintermann, Beat .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (21) :1969-1978
[6]   Total Ankle Arthroplasty Accuracy and Reproducibility Using Preoperative CT Scan-Derived, Patient-Specific Guides [J].
Berlet, Gregory C. ;
Penner, Murray J. ;
Lancianese, Sarah ;
Stemniski, Paul M. ;
Obert, Richard M. .
FOOT & ANKLE INTERNATIONAL, 2014, 35 (07) :665-676
[7]   Comparison of Mechanical Axis of the Limb Versus Anatomical Axis of the Tibia for Assessment of Tibiotalar Alignment in End-Stage Ankle Arthritis [J].
Bernasconi, Alessio ;
Najefi, Ali-Asgar ;
Goldberg, Andrew J. .
FOOT & ANKLE INTERNATIONAL, 2021, 42 (05) :616-623
[8]   Preliminary experience with the patient-specific templating total knee arthroplasty 40 cases compared with a matched control group [J].
Boonen, Bert ;
Schotanus, Martijn G. M. ;
Kort, Nanne P. .
ACTA ORTHOPAEDICA, 2012, 83 (04) :387-393
[9]   Outcome of Unilateral Ankle Arthrodesis and Total Ankle Replacement in Terms of Bilateral Gait Mechanics [J].
Chopra, Swati ;
Rouhani, Hossein ;
Assal, Mathieu ;
Aminian, Kamiar ;
Crevoisier, Xavier .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2014, 32 (03) :377-384
[10]   Survivorship and long-term outcome of a consecutive series of 200 Scandinavian Total Ankle Replacement (STAR) implants [J].
Clough, T. ;
Bodo, K. ;
Majeed, H. ;
Davenport, J. ;
Karski, M. .
BONE & JOINT JOURNAL, 2019, 101B (01) :47-54