Needle Aligned Ultrasound Image-Guided Access Through Dual-Segment Array

被引:1
作者
Rahaman, Ashiqur [1 ,2 ]
Tang, Yichuan [1 ]
Gao, Shang [1 ]
Ma, Xihan [1 ]
Sorokin, Igor [3 ]
Zhang, Haichong K. [1 ,2 ,4 ]
机构
[1] Worcester Polytech Inst, Dept Robot Engn, Worcester, MA 01609 USA
[2] Worcester Polytech Inst, Dept Biomed Engn, Worcester, MA 01609 USA
[3] Univ Massachusetts, Med Sch, Dept Urol, Worcester, MA USA
[4] Worcester Polytech Inst, Dept Comp Sci, Worcester, MA 01609 USA
基金
美国国家卫生研究院;
关键词
Needles; Acoustic beams; Probes; Kidney; Imaging; Image segmentation; Visualization; Needle-image alignment; Percutaneous intervention; Ultrasound-guided intervention; Dual-segment array; PERCUTANEOUS NEPHROLITHOTOMY; VISUALIZATION; GUIDANCE; FREEHAND; BIOPSY; SYSTEM;
D O I
10.1109/TBME.2023.3260735
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Ultrasound (US) guided access for percutaneous nephrolithotomy (PCNL) is gaining popularity in the urology community as it reduces radiation risk. The most popular technique involves manual image-needle alignment. A misaligned needle however needs to be retracted and reinserted, resulting in a lengthened operation time and complications such as bleeding. These limitations can be mitigated through the co-registration between the US array and needle. The through-hole array concept provides the primary solution, including a hole at the center of the array. Because of the central opening, the image-needle alignment is achieved inherently. Previous literature has described applications that are limited to superficial and intravascular procedures, suggesting that developing a through-hole array for deeper target applications would be a new breakthrough. Objective. Here, we present a dual-segment array with a central opening. As the prototype development, two segments of 32-element arrays are combined with an open space of 10 mm in length in between them. Method. We conducted phantom and ex-vivo studies considering the target depth of the 80-100 mm range. The image quality and needle visibility are evaluated by comparing the signal-to-noise ratio (SNR), full width at half maximum (FWHM), and contrast-to-noise ratio (CNR) results measured with a no-hole linear array under equivalent conditions. An ex-vivo study is performed using porcine kidneys with ceramic balls embedded to evaluate the needle access accuracy. Results and conclusion.The mean needle access error of 20 trials is found to be 2.94$\pm$1.09 mm, suggesting its potential impact on realizing a simple and intuitive deep US image-guided access.
引用
收藏
页码:2645 / 2654
页数:10
相关论文
共 44 条
  • [41] Preoperative Needle Insertion Path Planning for Minimizing Deflection in Multilayered Tissues
    Tsumura R.
    Kim J.S.
    Iwata H.
    Iordachita I.
    [J]. Tsumura, Ryosuke (ryosuke-tsumura@iwata.mech.waseda.ac.jp), 2018, Institute of Electrical and Electronics Engineers Inc., United States (03) : 2129 - 2136
  • [42] Tzou D. T., 2017, J ENDOUROL, V31, pS
  • [43] BEAM STEERING WITH LINEAR ARRAYS
    VONRAMM, OT
    SMITH, SW
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1983, 30 (08) : 438 - 452
  • [44] Robotic-assisted Respiration-Corrected 4D Ultrasound Imaging for Image-guided Interventions
    Wu, Jiaze
    Yan, Qian
    Ye, Jing
    Yuan, Xinsheng
    Liu, Jimin
    [J]. 2017 2ND INTERNATIONAL CONFERENCE ON MULTIMEDIA AND IMAGE PROCESSING (ICMIP), 2017, : 277 - 280