Needle Aligned Ultrasound Image-Guided Access Through Dual-Segment Array

被引:1
作者
Rahaman, Ashiqur [1 ,2 ]
Tang, Yichuan [1 ]
Gao, Shang [1 ]
Ma, Xihan [1 ]
Sorokin, Igor [3 ]
Zhang, Haichong K. [1 ,2 ,4 ]
机构
[1] Worcester Polytech Inst, Dept Robot Engn, Worcester, MA 01609 USA
[2] Worcester Polytech Inst, Dept Biomed Engn, Worcester, MA 01609 USA
[3] Univ Massachusetts, Med Sch, Dept Urol, Worcester, MA USA
[4] Worcester Polytech Inst, Dept Comp Sci, Worcester, MA 01609 USA
基金
美国国家卫生研究院;
关键词
Needles; Acoustic beams; Probes; Kidney; Imaging; Image segmentation; Visualization; Needle-image alignment; Percutaneous intervention; Ultrasound-guided intervention; Dual-segment array; PERCUTANEOUS NEPHROLITHOTOMY; VISUALIZATION; GUIDANCE; FREEHAND; BIOPSY; SYSTEM;
D O I
10.1109/TBME.2023.3260735
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Ultrasound (US) guided access for percutaneous nephrolithotomy (PCNL) is gaining popularity in the urology community as it reduces radiation risk. The most popular technique involves manual image-needle alignment. A misaligned needle however needs to be retracted and reinserted, resulting in a lengthened operation time and complications such as bleeding. These limitations can be mitigated through the co-registration between the US array and needle. The through-hole array concept provides the primary solution, including a hole at the center of the array. Because of the central opening, the image-needle alignment is achieved inherently. Previous literature has described applications that are limited to superficial and intravascular procedures, suggesting that developing a through-hole array for deeper target applications would be a new breakthrough. Objective. Here, we present a dual-segment array with a central opening. As the prototype development, two segments of 32-element arrays are combined with an open space of 10 mm in length in between them. Method. We conducted phantom and ex-vivo studies considering the target depth of the 80-100 mm range. The image quality and needle visibility are evaluated by comparing the signal-to-noise ratio (SNR), full width at half maximum (FWHM), and contrast-to-noise ratio (CNR) results measured with a no-hole linear array under equivalent conditions. An ex-vivo study is performed using porcine kidneys with ceramic balls embedded to evaluate the needle access accuracy. Results and conclusion.The mean needle access error of 20 trials is found to be 2.94$\pm$1.09 mm, suggesting its potential impact on realizing a simple and intuitive deep US image-guided access.
引用
收藏
页码:2645 / 2654
页数:10
相关论文
共 44 条
  • [11] Acoustic-resolution photoacoustic microscope based on compact and low-cost delta configuration actuator
    Gao, Shang
    Tsumura, Ryosuke
    Vang, Doua P.
    Bisland, Keion
    Xu, Keshuai
    Tsunoi, Yasuyuki
    Zhang, Haichong K.
    [J]. ULTRASONICS, 2022, 118
  • [12] Improving Needle Visualization by Novice Residents During an In-Plane Ultrasound Nerve Block Simulation Using an In-Plane Multiangle Needle Guide
    Gupta, Rajnish K.
    Lane, Jason
    Allen, Brian
    Shi, Yaping
    Schildcrout, Jonathan S.
    [J]. PAIN MEDICINE, 2013, 14 (10) : 1600 - 1607
  • [13] Single-Chip CMUT-on-CMOS Front-End System for Real-Time Volumetric IVUS and ICE Imaging
    Gurun, Gokce
    Tekes, Coskun
    Zahorian, Jaime
    Xu, Toby
    Satir, Sarp
    Karaman, Mustafa
    Hasler, Jennifer
    Degertekin, F. Levent
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2014, 61 (02) : 239 - 250
  • [14] ULTRASOUND AS A GUIDE IN PERCUTANEOUS PUNCTURE TECHNIQUE
    HOLM, HH
    KRISTENSEN, JK
    BARLEBO, H
    NORTHEVED, A
    RASMUSSEN, SN
    [J]. ULTRASONICS, 1972, 10 (02) : 83 - +
  • [15] A Probe-Camera System for 3D Ultrasound Image Reconstruction
    Ito, Koichi
    Yodokawa, Kouya
    Aoki, Takafumi
    Ohmiya, Jun
    Kondo, Satoshi
    [J]. IMAGING FOR PATIENT-CUSTOMIZED SIMULATIONS AND SYSTEMS FOR POINT-OF-CARE ULTRASOUND, 2017, 10549 : 129 - 137
  • [16] Jensen J. A., 1996, Medical & Biological Engineering & Computing, V34, P351
  • [17] CALCULATION OF PRESSURE FIELDS FROM ARBITRARILY SHAPED, APODIZED, AND EXCITED ULTRASOUND TRANSDUCERS
    JENSEN, JA
    SVENDSEN, NB
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1992, 39 (02) : 262 - 267
  • [18] Ultrasound Guidance Versus CT Guidance for Peripheral Lung Biopsy: Performance According to Lesion Size and Pleural Contact
    Lee, Matthew H.
    Lubner, Meghan G.
    Hinshaw, J. Louis
    Pickhardt, Perry J.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 210 (03) : W110 - W117
  • [19] Fluoroscopy versus ultrasound for image guidance during percutaneous nephrolithotomy: a systematic review and meta-analysis
    Liu, Qiang
    Zhou, Liang
    Cai, Xiang
    Jin, Tao
    Wang, Kunjie
    [J]. UROLITHIASIS, 2017, 45 (05) : 481 - 487
  • [20] Lojanapiwat Bannakij, 2013, Indian J Urol, V29, P208, DOI 10.4103/0970-1591.117284