Ceusia-Breast: computer-aided diagnosis with contrast enhanced ultrasound image analysis for breast lesions

被引:2
作者
Kondo, Satoshi [1 ]
Satoh, Megumi [2 ]
Nishida, Mutsumi [2 ]
Sakano, Ryousuke [2 ]
Takagi, Kazuya [3 ]
机构
[1] Muroran Inst Technol, Hokkaido, Japan
[2] Hokkaido Univ Hosp, Hokkaido, Japan
[3] Kon Minolta Inc, Tokyo, Japan
关键词
Contrast-enhanced ultrasonography; Breast lesion; Computer-aided diagnosis; Support vector machines; FOCAL LIVER-LESIONS; BENIGN; CLASSIFICATION; MULTICENTER; CANCER; DIFFERENTIATION;
D O I
10.1186/s12880-023-01072-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background In recent years, contrast-enhanced ultrasonography (CEUS) has been used for various applications in breast diagnosis. The superiority of CEUS over conventional B-mode imaging in the ultrasound diagnosis of the breast lesions in clinical practice has been widely confirmed. On the other hand, there have been many proposals for computer-aided diagnosis of breast lesions on B-mode ultrasound images, but few for CEUS. We propose a semi-automatic classification method based on machine learning in CEUS of breast lesions. Methods The proposed method extracts spatial and temporal features from CEUS videos and breast tumors are classified as benign or malignant using linear support vector machines (SVM) with combination of selected optimal features. In the proposed method, tumor regions are extracted using the guidance information specified by the examiners, then morphological and texture features of tumor regions obtained from B-mode and CEUS images and TIC features obtained from CEUS video are extracted. Then, our method uses SVM classifiers to classify breast tumors as benign or malignant. During SVM training, many features are prepared, and useful features are selected. We name our proposed method "Ceucia-Breast" (Contrast Enhanced UltraSound Image Analysis for BREAST lesions). Results The experimental results on 119 subjects show that the area under the receiver operating curve, accuracy, precision, and recall are 0.893, 0.816, 0.841 and 0.920, respectively. The classification performance is improved by our method over conventional methods using only B-mode images. In addition, we confirm that the selected features are consistent with the CEUS guidelines for breast tumor diagnosis. Furthermore, we conduct an experiment on the operator dependency of specifying guidance information and find that the intra-operator and inter- operator kappa coefficients are 1.0 and 0.798, respectively. Conclusion The experimental results show a significant improvement in classification performance compared to conventional classification methods using only B-mode images. We also confirm that the selected features are related to the findings that are considered important in clinical practice. Furthermore, we verify the intra- and interexaminer correlation in the guidance input for region extraction and confirm that both correlations are in strong agreement.
引用
收藏
页数:14
相关论文
共 48 条
  • [21] Lazo JF, 2020, Arxiv, DOI arXiv:2012.14517
  • [22] META-ANALYSIS: CONTRAST-ENHANCED ULTRASOUND VERSUS CONVENTIONAL ULTRASOUND FOR DIFFERENTIATION OF BENIGN AND MALIGNANT BREAST LESIONS
    Li, Qian
    Hu, Min
    Chen, Zhikui
    Li, Changtian
    Zhang, Xi
    Song, Yiqing
    Xiang, Feixiang
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2018, 44 (05) : 919 - 929
  • [23] Deep fusion of human-machine knowledge with attention mechanism for breast cancer diagnosis
    Luo, Yaozhong
    Lu, Zhenkun
    Liu, Longzhong
    Huang, Qinghua
    [J]. BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2023, 84
  • [24] Convolutional neural network-based models for diagnosis of breast cancer
    Masud, Mehedi
    Rashed, Amr E. Eldin
    Hossain, M. Shamim
    [J]. NEURAL COMPUTING & APPLICATIONS, 2022, 34 (14) : 11383 - 11394
  • [25] Accurate evaluation of axillary sentinel lymph node metastasis using contrast-enhanced ultrasonography with Sonazoid in breast cancer: a preliminary clinical trial
    Matsuzawa, Fumihiko
    Omoto, Kiyoka
    Einama, Takahiro
    Abe, Hironori
    Suzuki, Takashi
    Hamaguchi, Jun
    Kaga, Terumi
    Sato, Mami
    Oomura, Masako
    Takata, Yumiko
    Fujibe, Ayako
    Takeda, Chie
    Tamura, Etsuya
    Taketomi, Akinobu
    Kyuno, Kenichi
    [J]. SPRINGERPLUS, 2015, 4
  • [26] Hookwire-guided Sentinel Lymph Node Biopsy Using Contrast-enhanced Ultrasonography Followed by a One-step Nucleic Acid Amplification (OSNA) Assay for Breast Cancer
    Miyake, Tomohiro
    Shimazu, Kenzo
    Tanei, Tomonori
    Naoi, Yasuto
    Kagara, Naofumi
    Shimoda, Masafumi
    Kim, Seung Jin
    Noguchi, Shinzaburo
    [J]. ANTICANCER RESEARCH, 2019, 39 (11) : 6183 - 6192
  • [27] Efficacy of Sonazoid (Perflubutane) for Contrast-Enhanced Ultrasound in the Differentiation of Focal Breast Lesions: Phase 3 Multicenter Clinical Trial
    Miyamoto, Yukio
    Ito, Toshikazu
    Takada, Etsuo
    Omoto, Kiyoka
    Hirai, Toshiko
    Moriyasu, Fuminori
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 202 (04) : W400 - W407
  • [28] Nascimento Carmina Dessana Lima, 2016, Res. Biomed. Eng., V32, P283
  • [29] Nemcova E, 2015, EUR C RAD ECR 2015
  • [30] Detection of hepatic metastases with low MI real time contrast enhanced sonography and SonoVue®
    Oldenburg, A
    Hohmann, J
    Foert, E
    Skrok, J
    Hoffmann, CW
    Frericks, B
    Wolf, KJ
    Albrecht, T
    [J]. ULTRASCHALL IN DER MEDIZIN, 2005, 26 (04): : 277 - 284