Usefulness of Breath-Hold Fat-Suppressed T2-Weighted Images With Deep Learning-Based Reconstruction of the Liver Comparison to Conventional Free-Breathing Turbo Spin Echo

被引:14
作者
Ichinohe, Fumihito [1 ]
Oyama, Kazuki [1 ]
Yamada, Akira [1 ]
Hayashihara, Hayato [2 ]
Adachi, Yasuo [2 ]
Kitoh, Yoshihiro [2 ]
Kanki, Yusuke [3 ]
Maruyama, Katsuya [4 ]
Nickel, Marcel Dominik [5 ]
Fujinaga, Yasunari [1 ]
机构
[1] Shinshu Univ, Sch Med, Dept Radiol, 3-1-1 Asahi, Matsumoto 3908621, Japan
[2] Shinshu Univ Hosp, Radiol Div, Matsumoto, Japan
[3] Siemens Healthcare KK, Magnet Resonance Dept, Tokyo, Japan
[4] Siemens Healthcare KK, MR Res & Collaborat Dept, Tokyo, Japan
[5] Siemens Healthcare GmbH, MR Applicat Predev, Erlangen, Germany
关键词
magnetic resonance imaging; T2-weighted image; liver; deep learning; free-breathing; breath-hold; turbo spin echo; half Fourier single-shot turbo spin echo; BLADE TECHNIQUE; MRI; QUALITY; ABDOMEN; FEASIBILITY; ACQUISITION; SEQUENCE; HASTE; T2WI;
D O I
10.1097/RLI.0000000000000943
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectivesThe aim of this study was to evaluate the usefulness of breath-hold turbo spin echo with deep learning-based reconstruction (BH-DL-TSE) in acquiring fat-suppressed T2-weighted images (FS-T2WI) of the liver by comparing this method with conventional free-breathing turbo spin echo (FB-TSE) and breath-hold half Fourier single-shot turbo spin echo with deep learning-based reconstruction (BH-DL-HASTE).Materials and MethodsThe study cohort comprised 111 patients with suspected liver disease who underwent 3 T magnetic resonance imaging. Fifty-eight focal solid liver lesions >= 10 mm were also evaluated. Three sets of FS-T2WI were acquired using FB-TSE, prototypical BH-DL-TSE, and prototypical BH-DL-HASTE, respectively. In the qualitative analysis, 2 radiologists evaluated the image quality using a 5-point scale. In the quantitative analysis, we calculated the lesion-to-liver signal intensity ratio (LEL-SIR). Friedman test and Dunn multiple comparison test were performed to assess differences among 3 types of FS-T2WI with respect to image quality and LEL-SIR.ResultsThe mean acquisition time was 4 minutes and 43 seconds +/- 1 minute and 21 seconds (95% confidence interval, 4 minutes and 28 seconds to 4 minutes and 58 seconds) for FB-TSE, 40 seconds for BH-DL-TSE, and 20 seconds for BH-DL-HASTE. In the qualitative analysis, BH-DL-HASTE resulted in the fewest respiratory motion artifacts (P < 0.0001). BH-DL-TSE and FB-TSE exhibited significantly less motion-related signal loss and clearer intrahepatic vessels than BH-DL-HASTE (P < 0.0001). Regarding the edge sharpness of the left lobe, BH-DL-HASTE scored the highest (P < 0.0001), and BH-DL-TSE scored higher than FB-TSE (P = 0.0290). There were no significant differences among 3 types of FS-T2WI with respect to the edge sharpness of the right lobe (P = 0.1290), lesion conspicuity (P = 0.5292), and LEL-SIR (P = 0.6026).ConclusionsBH-DL-TSE provides a shorter acquisition time and comparable or better image quality than FB-TSE, and could replace FB-TSE in acquiring FS-T2WI of the liver. BH-DL-TSE and BH-DL-HASTE have their own advantages and may be used complementarily.
引用
收藏
页码:373 / 379
页数:7
相关论文
共 25 条
[1]   Phase2Phase Respiratory Motion-Resolved Reconstruction of Free-Breathing Magnetic Resonance Imaging Using Deep Learning Without a Ground Truth for Improved Liver Imaging [J].
Eldeniz, Cihat ;
Gan, Weijie ;
Chen, Sihao ;
Fraum, Tyler J. ;
Ludwig, Daniel R. ;
Yan, Yan ;
Liu, Jiaming ;
Vahle, Thomas ;
Krishnamurthy, Uday ;
Kamilov, Ulugbek S. ;
An, Hongyu .
INVESTIGATIVE RADIOLOGY, 2021, 56 (12) :809-819
[2]  
Endler CH., 2022, INVEST RADIOL, V57, P470
[3]   Imaging evaluation of the liver in oncology patients: A comparison of techniques [J].
Freitas, Patricia S. ;
Janicas, Catarina ;
Veiga, Jose ;
Matos, Antonio P. ;
Heredia, Vasco ;
Ramalho, Miguel .
WORLD JOURNAL OF HEPATOLOGY, 2021, 13 (12) :1936-1955
[4]   Accelerated T2-Weighted TSE Imaging of the Prostate Using Deep Learning Image Reconstruction: A Prospective Comparison with Standard T2-Weighted TSE Imaging [J].
Gassenmaier, Sebastian ;
Afat, Saif ;
Nickel, Marcel Dominik ;
Mostapha, Mahmoud ;
Herrmann, Judith ;
Almansour, Haidara ;
Nikolaou, Konstantin ;
Othman, Ahmed E. .
CANCERS, 2021, 13 (14)
[5]   Application of a Novel Iterative Denoising and Image Enhancement Technique in T1-Weighted Precontrast and Postcontrast Gradient Echo Imaging of the Abdomen Improvement of Image Quality and Diagnostic Confidence [J].
Gassenmaier, Sebastian ;
Afat, Saif ;
Nickel, Dominik ;
Kannengiesser, Stephan ;
Herrmann, Judith ;
Hoffmann, Ruediger ;
Othman, Ahmed E. .
INVESTIGATIVE RADIOLOGY, 2021, 56 (05) :328-334
[6]   Learning a variational network for reconstruction of accelerated MRI data [J].
Hammernik, Kerstin ;
Klatzer, Teresa ;
Kobler, Erich ;
Recht, Michael P. ;
Sodickson, Daniel K. ;
Pock, Thomas ;
Knoll, Florian .
MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (06) :3055-3071
[7]   Feasibility and Implementation of a Deep Learning MR Reconstruction for TSE Sequences in Musculoskeletal Imaging [J].
Herrmann, Judith ;
Koerzdoerfer, Gregor ;
Nickel, Dominik ;
Mostapha, Mahmoud ;
Nadar, Mariappan ;
Gassenmaier, Sebastian ;
Kuestner, Thomas ;
Othman, Ahmed E. .
DIAGNOSTICS, 2021, 11 (08)
[8]   Development and Evaluation of Deep Learning-Accelerated Single-Breath-Hold Abdominal HASTE at 3 T Using Variable Refocusing Flip Angles [J].
Herrmann, Judith ;
Nickel, Dominik ;
Mugler, John P. ;
Arberet, Simon ;
Gassenmaier, Sebastian ;
Afat, Saif ;
Nikolaou, Konstantin ;
Othman, Ahmed E. .
INVESTIGATIVE RADIOLOGY, 2021, 56 (10) :645-652
[9]   Diagnostic Confidence and Feasibility of a Deep Learning Accelerated HASTE Sequence of the Abdomen in a Single Breath-Hold [J].
Herrmann, Judith ;
Gassenmaier, Sebastian ;
Nickel, Dominik ;
Arberet, Simon ;
Afat, Saif ;
Lingg, Andreas ;
Kundel, Matthias ;
Othman, Ahmed E. .
INVESTIGATIVE RADIOLOGY, 2021, 56 (05) :313-319
[10]   Comparison of three free breathing T2-weighted MRI sequences in the evaluation of focal liver lesions [J].
Kim, Bong Soo ;
Kim, Jung Hoon ;
Choi, Guk Myung ;
Kim, Seung Hyoung ;
Park, Ji Kang ;
Song, Byung-Cheol ;
Kang, Weechang .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (01) :W19-W27