Long-term follow-up of selective and non-selective His bundle pacing leads in patients with atrioventricular block

被引:6
作者
Frausing, Maria Hee Jung Park [1 ,2 ]
Baek, Aleksander Laust [1 ,2 ]
Kristensen, Jens [1 ,2 ]
Gerdes, Christian [1 ,2 ]
Nielsen, Jens Cosedis [1 ,2 ]
Kronborg, Mads Brix [1 ,2 ]
机构
[1] Aarhus Univ Hosp, Dept Cardiol, Palle Juul Jensens Bvld 99, DK-8200 Aarhus, Denmark
[2] Aarhus Univ, Dept Clin Med, Palle Juul Jensens Bvld 82, DK-8200 Aarhus, Denmark
关键词
Pacemaker; Lead performance; His bundle pacing; Conduction system pacing; AV block; PERFORMANCE;
D O I
10.1007/s10840-023-01488-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background His bundle pacing (HBP) is a novel treatment with limited knowledge on long-term outcome. We aimed to assess long-term safety and effectiveness of HBP in patients with atrioventricular block treated with HBP and a back-up right ventricular pacing (RVP) lead.Methods We included 38 patients from a completed single-center, randomized controlled cross-over trial designed to compare left ventricular (LV) function after 12 months of HBP vs. RVP conducted between September 2007 and August 2011. Lead performance beyond the 2-year study period was assessed based on a retrospective review of capture thresholds, sensing, impedance, energy consumption, and rate of HBP interruption.Results Patients were followed for a mean of 7 +/- 4 years. Both at baseline and during follow-up, HBP leads displayed significantly higher capture thresholds than RVP leads (P < 0.001), multifold higher energy consumption (P < 0.001), and lower sensing amplitudes (P < 0.001). During follow-up, 17 (53%) HBP leads were deactivated or abandoned. The principal cause for HBP interruption was high pacing thresholds in patients with preserved LVEF during RVP. Device longevity was shorter than that of contemporary cohorts treated with dual-chamber pacing or CRT, and time to first device exchange was 6.8 +/- 1.5 years. No lead dislodgements occurred, but four patients (10%) developed device-related infections requiring device extraction.Conclusion HBP was interrupted in > 50% of patients during long-term follow-up. The principal cause was unacceptably high capture thresholds and no significant difference in LV function with HBP compared with RVP. Device longevity was shorter, and infection rates were higher than anticipated.
引用
收藏
页码:1849 / 1857
页数:9
相关论文
共 50 条
[41]   Study design and protocol for evaluating the long-term prognosis of patients receiving his bundle pacing: A multicenter observational study [J].
Yanagisawa, Satoshi ;
Inden, Yasuya ;
Kato, Hiroyuki ;
Suzuki, Hirohiko ;
Fujita, Masaya ;
Ishikawa, Shinji ;
Kanzaki, Yasunori ;
Kamikubo, Yosuke ;
Murase, Yosuke ;
Murohara, Toyoaki ;
Shibata, Rei .
JOURNAL OF ARRHYTHMIA, 2019, 35 (05) :760-765
[42]   Long-term Outcome of Atrial Synchronous Mode Pacing in Patients With Atrioventricular Block Using a Single Lead [J].
Blich, Miry ;
Suleiman, Mahmoud ;
Shwiri, Tawfiq Zeidan ;
Marai, Ibrahim ;
Boulos, Monther ;
Amikam, Shlomo .
CLINICAL CARDIOLOGY, 2010, 33 (01) :18-22
[43]   Long-term follow-up of abandoned transvenous defibrillator leads: a nationwide cohort study [J].
Elgaard, Anders Fyhn ;
Johansen, Jens Brock ;
Nielsen, Jens Cosedis ;
Gerdes, Christian ;
Riahi, Sam ;
Philbert, Berit Thornvig ;
Haarbo, Jens ;
Melchior, Thomas Maria ;
Larsen, Jacob Moesgaard .
EUROPACE, 2020, 22 (07) :1097-1102
[44]   Acute echocardiographic and hemodynamic response to his-bundle pacing in patients with first-degree atrioventricular block [J].
Loring, Zak ;
Holmqvist, Fredrik ;
Sze, Edward ;
Alenezi, Fawaz ;
Campbell, Kristen ;
Koontz, Jason, I ;
Velazquez, Eric J. ;
Atwater, Brett D. ;
Bahnson, Tristram D. ;
Daubert, James P. .
ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2022, 27 (04)
[45]   His-bundle and left bundle pacing with optimized atrioventricular delay achieve superior electrical synchrony over endocardial and epicardial pacing in left bundle branch block patients [J].
Strocchi, Marina ;
Lee, Angela W. C. ;
Neic, Aurel ;
Bouyssier, Julien ;
Gillette, Karli ;
Plank, Gernot ;
Elliott, Mark K. ;
Gould, Justin ;
Behar, Jonathan M. ;
Sidhu, Baldeep ;
Mehta, Vishal ;
Bishop, Martin J. ;
Vigmond, Edward J. ;
Rinaldi, Christopher A. ;
Niederer, Steven A. .
HEART RHYTHM, 2020, 17 (11) :1922-1929
[46]   Permanent His-bundle pacing: Long-term lead performance and clinical outcomes [J].
Vijayaraman, Pugazhendhi ;
Naperkowski, Angela ;
Subzposh, Faiz A. ;
Abdelrahman, Mohamed ;
Sharma, Parikshit S. ;
Oren, Jess W. ;
Dandamudi, Gopi ;
Ellenbogen, Kenneth A. .
HEART RHYTHM, 2018, 15 (05) :696-702
[47]   Long-term performance and risk factors analysis after permanent His-bundle pacing and atrioventricular node ablation in patients with atrial fibrillation and heart failure [J].
Su, Lan ;
Cai, Mengxing ;
Wu, Shengjie ;
Wang, Songjie ;
Xu, Tiancheng ;
Vijayaraman, Pugazhendhi ;
Huang, Weijian .
EUROPACE, 2020, 22 :19-26
[48]   Feasibility of Conduction System Pacing in Patients with Baseline Bundle Branch Block-A Single-Center Mid-Term Follow-Up Study [J].
Pestrea, Catalin ;
Rusu, Marcela ;
Enache, Roxana ;
Cicala, Ecaterina ;
Gavrilescu, Radu ;
Vaduva, Adrian ;
Ortan, Florin ;
Iorgulescu, Corneliu ;
Vatasescu, Radu .
JOURNAL OF CLINICAL MEDICINE, 2024, 13 (02)
[49]   Long-term outcome in patients receiving permanent pacemaker implantation for atrioventricular block: Comparison of VDD and DDD pacing [J].
Liao, Jo-Nan ;
Chao, Tze-Fan ;
Tuan, Ta-Chuan ;
Kong, Chi-Woon ;
Chen, Shih-Ann .
MEDICINE, 2016, 95 (35)
[50]   Procedural outcome and follow-up of stylet-driven leads compared with lumenless leads for left bundle branch area pacing [J].
Sritharan, Aarthiga ;
Kozhuharov, Nikola ;
Masson, Nicolas ;
Bakelants, Elise ;
Valiton, Valerian ;
Burri, Haran .
EUROPACE, 2023, 25 (10)