Long-term follow-up of selective and non-selective His bundle pacing leads in patients with atrioventricular block

被引:5
|
作者
Frausing, Maria Hee Jung Park [1 ,2 ]
Baek, Aleksander Laust [1 ,2 ]
Kristensen, Jens [1 ,2 ]
Gerdes, Christian [1 ,2 ]
Nielsen, Jens Cosedis [1 ,2 ]
Kronborg, Mads Brix [1 ,2 ]
机构
[1] Aarhus Univ Hosp, Dept Cardiol, Palle Juul Jensens Bvld 99, DK-8200 Aarhus, Denmark
[2] Aarhus Univ, Dept Clin Med, Palle Juul Jensens Bvld 82, DK-8200 Aarhus, Denmark
关键词
Pacemaker; Lead performance; His bundle pacing; Conduction system pacing; AV block; PERFORMANCE;
D O I
10.1007/s10840-023-01488-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background His bundle pacing (HBP) is a novel treatment with limited knowledge on long-term outcome. We aimed to assess long-term safety and effectiveness of HBP in patients with atrioventricular block treated with HBP and a back-up right ventricular pacing (RVP) lead.Methods We included 38 patients from a completed single-center, randomized controlled cross-over trial designed to compare left ventricular (LV) function after 12 months of HBP vs. RVP conducted between September 2007 and August 2011. Lead performance beyond the 2-year study period was assessed based on a retrospective review of capture thresholds, sensing, impedance, energy consumption, and rate of HBP interruption.Results Patients were followed for a mean of 7 +/- 4 years. Both at baseline and during follow-up, HBP leads displayed significantly higher capture thresholds than RVP leads (P < 0.001), multifold higher energy consumption (P < 0.001), and lower sensing amplitudes (P < 0.001). During follow-up, 17 (53%) HBP leads were deactivated or abandoned. The principal cause for HBP interruption was high pacing thresholds in patients with preserved LVEF during RVP. Device longevity was shorter than that of contemporary cohorts treated with dual-chamber pacing or CRT, and time to first device exchange was 6.8 +/- 1.5 years. No lead dislodgements occurred, but four patients (10%) developed device-related infections requiring device extraction.Conclusion HBP was interrupted in > 50% of patients during long-term follow-up. The principal cause was unacceptably high capture thresholds and no significant difference in LV function with HBP compared with RVP. Device longevity was shorter, and infection rates were higher than anticipated.
引用
收藏
页码:1849 / 1857
页数:9
相关论文
共 50 条
  • [1] Long-term follow-up of selective and non-selective His bundle pacing leads in patients with atrioventricular block
    Maria Hee Jung Park Frausing
    Aleksander Laust Bæk
    Jens Kristensen
    Christian Gerdes
    Jens Cosedis Nielsen
    Mads Brix Kronborg
    Journal of Interventional Cardiac Electrophysiology, 2023, 66 : 1849 - 1857
  • [2] Selective His Bundle Pacing in a Patient With Ebstein's Anomaly and Atrioventricular Block
    Patel, Neil
    Bauch, Terry
    Calkins, Hugh
    Vijayaraman, Pugazhendhi
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2021, 7 (02) : 275 - 276
  • [3] Selective versus non-selective his bundle pacing for cardiac resynchronization therapy
    Upadhyay, Gaurav A.
    Tung, Roderick
    JOURNAL OF ELECTROCARDIOLOGY, 2017, 50 (02) : 191 - 194
  • [4] Permanent His bundle pacing: Electrophysiological and echocardiographic observations from long-term follow-up
    Vijayaraman, Pugazhendhi
    Dandamudi, Gopi
    Lustgarten, Daniel
    Ellenbogen, Kenneth A.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2017, 40 (07): : 883 - 891
  • [5] His bundle pacing in nodal versus infranodal atrioventricular block: a mid-term follow-up study
    Pestrea, Catalin
    Cicala, Ecaterina
    Gherghina, Alexandra
    Ortan, Florin
    Pop, Dana
    OPEN HEART, 2023, 10 (02):
  • [6] His bundle pacing capture threshold stability during long-term follow-up and correlation with lead slack
    Beer, Dominik
    Subzposh, Faiz A.
    Colburn, Shaun
    Naperkowski, Angela
    Vijayaraman, Pugazhendhi
    EUROPACE, 2021, 23 (05): : 757 - 766
  • [7] Long-term follow-up in patients with intra-Hisian atrioventricular block
    Ishikawa T.
    Sumita S.
    Kikuchi M.
    Nakagawa T.
    Ogawa H.
    Hanada K.
    Kobayashi I.
    Kosuge M.
    Shigemasa T.
    Endo T.
    Kimura K.
    Usui T.
    Umemura S.
    Journal of Artificial Organs, 2000, 3 (2) : 149 - 153
  • [8] Non-selective His bundle pacing with a biphasic waveform: enhancing septal resynchronization
    Ortega, Daniel F.
    Barja, Luis D.
    Logarzo, Emilio
    Mangani, Nicolas
    Paolucci, Analia
    Bonomini, Maria P.
    EUROPACE, 2018, 20 (05): : 816 - 822
  • [9] Long-term follow-up of DDD pacing mode
    Ulman, Mateusz
    Debski, Maciej
    Zabek, Andrzej
    Haberka, Kazimierz
    Lelakowski, Jacek
    Malecka, Barbara
    KARDIOLOGIA POLSKA, 2014, 72 (06) : 519 - 526
  • [10] Long-term Follow-up of AV Node Ablation and His Bundle Pacing as a Strategy for Atrial Arrhythmia Control
    Rodriguez-Albarran, Adrian
    Moraleda-Salas, Maria Teresa
    Esteve-Ruiz, Irene
    Arce-Leon, Alvaro
    Morina-Vazquez, Pablo
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 : S24 - S25