Measuring Arterial Oxygen Saturation Using Wearable Devices Under Varying Conditions

被引:8
作者
Hearn, Eleanor L. [1 ]
Byford, Jack [1 ]
Wolfe, Christopher [1 ]
Agyei, Cheryl [1 ]
Hodkinson, Peter D. [1 ]
Pollock, Ross D. [1 ]
Smith, Thomas G. [1 ]
机构
[1] Kings Coll London, London, England
关键词
pulse oximeter; pilot; hypoxemia; altitude; aviation; spaceflight;
D O I
10.3357/AMHP.6078.2023
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
INTRODUCTION: Recently developed wearable monitoring devices can provide arterial oxygen saturation (S(p)o(2)) measurements, offering potential for use in aerospace operations. Pilots and passengers are already using these technologies, but their performance has not yet been established under conditions experienced in the flight environment such as environmental hypoxia and concurrent body motion. METHODS: An initial evaluation was conducted in 10 healthy subjects who were studied in a normobaric chamber during normoxia and at a simulated altitude of 15,000 ft (4572 m; 11.8% oxygen). S(p)o(2) was measured simultaneously using a standard pulse oximeter and four wearable devices: Apple Watch Series 6; Garmin Fenix 6 watch; Cosinusso Two in-ear sensor; and Oxitone 1000M wrist-worn pulse oximeter. Measurements were made while stationary at rest, during very slight body motion (induced by very low intensity cycling at 30 W on an ergometer), and during moderate body motion (induced by moderate intensity cycling at 150 W). RESULTS: Missed readings, defined as failure to record an Spo2 value within 1 min, occurred commonly with all wearables. Even with only very slight body motion, most devices missed most readings (range of 12-82% missed readings) and the rate was higher with greater body motion (range 18-92%). One device tended to under-report S(p)o(2), while the other devices tended to over-report S(p)o(2). Performance decreased across the devices when oxygenation was reduced. DISCUSSION: In this preliminary evaluation, the wearable devices studied did not perform to the same standard as a traditional pulse oximeter. These limitations may restrict their utility in flight and require further investigation.
引用
收藏
页码:42 / 47
页数:6
相关论文
共 13 条
  • [1] [Anonymous], 2021, PULS OX ACC LIM
  • [2] Mild Hypoxia of a Skydiver Making Repeated, Medium-Altitude Aircraft Exits
    Bradke, Brian S.
    Everman, Bradford R.
    [J]. AEROSPACE MEDICINE AND HUMAN PERFORMANCE, 2020, 91 (02) : 110 - 115
  • [3] Ernsting J, 2005, 53 INT C AVIATION SP, P11
  • [4] Dark Skin Decreases the Accuracy of Pulse Oximeters at Low Oxygen Saturation: The Effects of Oximeter Probe Type and Gender
    Feiner, John R.
    Severinghaus, John W.
    Bickler, Philip E.
    [J]. ANESTHESIA AND ANALGESIA, 2007, 105 : S18 - S23
  • [5] Grand View Research, 2021, WEARABLE TECHNOLOGY, P1
  • [6] Wrist-Sensor Pulse Oximeter Enables Prolonged Patient Monitoring in Chronic Lung Diseases
    Guber, Alexander
    Shochet, Gali Epstein
    Kohn, Sarah
    Shitrit, David
    [J]. JOURNAL OF MEDICAL SYSTEMS, 2019, 43 (07)
  • [7] Accuracy and Reliability of Commercial Wrist-Worn Pulse Oximeter During Normobaric Hypoxia Exposure Under Resting Conditions
    Lauterbach, Claire J.
    Romano, Phebe A.
    Greisler, Luke A.
    Brindle, Richard A.
    Ford, Kevin R.
    Kuennen, Matthew R.
    [J]. RESEARCH QUARTERLY FOR EXERCISE AND SPORT, 2021, 92 (03) : 549 - 558
  • [8] Motion Artifact Reduction in Wearable Photoplethysmography Based on Multi-Channel Sensors with Multiple Wavelengths
    Lee, Jongshill
    Kim, Minseong
    Park, Hoon-Ki
    Kim, In Young
    [J]. SENSORS, 2020, 20 (05)
  • [9] Guidelines for wrist-worn consumer wearable assessment of heart rate in biobehavioral research
    Nelson, Benjamin W.
    Low, Carissa A.
    Jacobson, Nicholas
    Arean, Patricia
    Torous, John
    Allen, Nicholas B.
    [J]. NPJ DIGITAL MEDICINE, 2020, 3 (01)
  • [10] The Effect of Motion on Pulse Oximetry and Its Clinical Significance
    Petterson, Michael T.
    Begnoche, Valerie L.
    Graybeal, John M.
    [J]. ANESTHESIA AND ANALGESIA, 2007, 105 : S78 - S84