Anatomical and Biomechanical Stability of Single/Double Screw-Cancellous Bone Fixations of Regan-Morry Type III Ulnar Coronoid Fractures in Adults: CT Measurement and Finite Element Analysis

被引:2
作者
Ye, Hao [1 ]
Yang, Yongchao [2 ]
Xing, Tingyang [1 ]
Tan, Guirong [1 ]
Jin, Shuxun [1 ]
Zhao, Zhichao [1 ]
Zhang, Weikang [1 ]
Li, Yanyan [1 ]
Zhang, Lei [3 ]
Wang, Jianshun [4 ]
Zheng, Rongmei [1 ]
Lu, Yun [2 ]
Wu, Lijun [1 ,5 ]
机构
[1] Wenzhou Med Univ, Inst Digitized Med & Intelligent Technol, Wenzhou, Peoples R China
[2] Tianjin Teda Hosp, Dept Orthoped, Tianjin, Peoples R China
[3] Wenzhou Med Univ, Affiliated Hosp 3, Dept Orthoped, Wenzhou, Peoples R China
[4] Wenzhou Med Univ, Affiliated Hosp 2, Dept Orthoped, Wenzhou, Peoples R China
[5] Wenzhou Med Univ, Inst Digitized Med & Intelligent Technol, Wenzhou 325000, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Anatomical and Biomechanical Stability; Digital Orthopaedics Surgery; Finite Element Method; Smart Screw Internal Fixation; Ulnar Coronoid Fracture; PULLOUT STRENGTH; RADIAL HEAD; ELBOW;
D O I
10.1111/os.13664
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: At present, it is still uncertain whether single screw has the same stability as double screws in the treatment of ulnar coronal process basal fracture (Regan-Morry type III). So, we aimed to compare the pull-out force and anti-rotation torque of anterior single/double screw-cancellous bone fixation (aSSBF, aDSBF) in this fracture, and further study the influencing factors on anatomical and biomechanical stability of smart screw internal fixations. Methods: A total of 63 adult volunteers with no history of elbow injury underwent elbow CT scanning with associated three-dimensional reconstruction that enabled the measurements of bone density and fixed length of the proximal ulna and coronoid. The models of coronal process basal fracture, aSSBF and aDSBF, were developed and validated. Using the finite element model test, the sensitivity analysis of pull-out force and rotational torque was carried out. Results: The pull-out force of aSSBF model was positively correlated with the density of the cancellous bone and linearly related to the fixed depth of the screw. The load pattern of pull-out force of aDSBF model was similar to that of aSSBF model. The ultimate torque of aDSBF model was higher than that of aSSBF model, but the load pattern of ultimate torque of both models was similar to each other when the fracture reset was satisfactory, and the screw nut attaches closely to coronoid process. Moreover, with enhancement of initial pre-tightening force, the increase of ultimate torque of both models was small. Conclusions: In addition to three pull-out stability factors of smart screw fixations, fracture surface fitting degree and nut fitting degree are the other two important anatomical and biomechanical stability factors of smart screw fixations both for rotational stability. When all pull-out stability and rotational stability factors meet reasonable conditions simultaneously, single or double screw fixation methods are stable for the treatments of ulnar coronoid basal fractures.
引用
收藏
页码:1072 / 1084
页数:13
相关论文
共 29 条
[1]   Ulnar coronoid process anatomy - Possible implications for elbow instability [J].
Ablove, Robert H. ;
Moy, Owen J. ;
Howard, Craig ;
Peimer, Clayton A. ;
S'Doia, Samuel .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (449) :259-261
[2]   Trabecular bone strength predictions using finite element analysis of micro-scale images at limited spatial resolution [J].
Bevill, Grant ;
Keaveny, Tony M. .
BONE, 2009, 44 (04) :579-584
[3]   Coronoid Fractures [J].
Budoff, Jeffrey E. .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2012, 37A (11) :2418-2423
[4]   Factors affecting the pullout strength of cancellous bone screws [J].
Chapman, JR ;
Harrington, RM ;
Lee, KM ;
Anderson, PA ;
Tencer, AF ;
Kowalski, D .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1996, 118 (03) :391-398
[5]   A parametric study of cylindrical pedicle screw design implications on the pullout performance using an experimentally validated finite-element model [J].
Chatzistergos, Panagiotis E. ;
Magnissalis, Evangelos A. ;
Kourkoulis, Stavros K. .
MEDICAL ENGINEERING & PHYSICS, 2010, 32 (02) :145-154
[6]   Coronoid fracture patterns [J].
Doornberg, JN ;
Ring, D .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (01) :45-52
[7]   Homogenized finite element models can accurately predict screw pull-out in continuum materials, but not in porous materials [J].
Einafshar, Mohammadjavad ;
Hashemi, Ata ;
van Lenthe, G. Harry .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2021, 202
[8]   One-Screw Fixation Provides Similar Stability to That of Two-Screw Fixation for Type II Dens Fractures [J].
Feng, Gang ;
Wendlandt, Robert ;
Spuck, Sebastian ;
Schulz, Arndt P. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (07) :2021-2028
[9]   Can barb thread design improve the pullout strength of bone screws? A BIOMECHANICAL STUDY AND FINITE ELEMENT EXPLANATION [J].
Feng, X. ;
Qi, W. ;
Fang, C. X. ;
Lu, W. W. ;
Leung, F. K. L. ;
Chen, B. .
BONE & JOINT RESEARCH, 2021, 10 (02) :105-112
[10]   Fixation of the Coronoid Process in Elbow Fracture-Dislocations [J].
Garrigues, Grant E. ;
Wray, Walter H., III ;
Lindenhovius, Anneluuk L. C. ;
Ring, David C. ;
Ruch, David S. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (20) :1873-1881