AngioJet rheolytic thrombectomy coupled with dose-reduced rt-PA for massive inferior vena cava filter-related thrombosis: A single-center retrospective study

被引:0
|
作者
Gong, Maofeng [1 ]
Zhao, Qing [2 ]
Jiang, Rui [1 ]
Liu, Zhengli [1 ]
Zhao, Boxiang [1 ]
Kong, Jie [1 ]
He, Xu [1 ]
Gu, Jianping [1 ,3 ]
机构
[1] Nanjing Med Univ, Nanjing Hosp 1, Dept Intervent & Vasc Radiol, Nanjing 210006, Jiangsu, Peoples R China
[2] Nanjing Med Univ, Dept Gastroenterol, Affiliated Jiangning Hosp, Nanjing 211100, Jiangsu, Peoples R China
[3] Nanjing Med Univ, Nanjing Hosp 1, Dept Vasc & Intervent Radiol, Nanjing 210006, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Vena cava filter; Venous thrombosis; Thrombotic therapy; Catheter-directed thrombolysis; Percutaneous mechanical thrombectomy; CATHETER-DIRECTED THROMBOLYSIS; DEEP-VEIN THROMBOSIS; PREVENTION; MANAGEMENT;
D O I
10.1016/j.asjsur.2023.08.098
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: To evaluate the efficacy and safety of AngioJet rheolytic thrombectomy (ART) coupled with dose-reduced rt-PA, compared to catheter-directed thrombolysis (CDT) alone, for the treatment of massive inferior vena cava filter (IVCF)-related thrombosis. Methods: We conducted a retrospective analysis of 40 patients who received either ART or CDT alone as the first-line endovascular therapy (ET) between January, 2016 and September, 2022. The data on demographics, clinical characteristics, technical success, clinical success, complications, and early follow-up were reviewed. Results: Of the 40 included patients, 24 received ART and 16 received CDT alone. The demographics, presentation, lesion characteristics, comorbidities and risk factors were comparable (all p > .05). Technical success rates were 100% in both groups. The total CDT time and infusion agent dosage were lower in the ART group than those in the CDT group (both p < .05). At the end of CDT, clinical success was 81.8% in the ART group, which was slightly higher than that of 70.8% in the CDT group (p > .05). At the 6-month follow-up, the incidences of recurrent thrombosis in the two groups were 6.9% and 15.8%, respectively, and the incidence of post-thrombotic syndrome was 10.3% and 21.1%, respectively. However, these differences were not statistically significant (p > .05). No major complications were noted in either group, ART seemed to have slightly higher risk of transient macroscopic hemoglobinuria and recoverable acute kidney injury, but with a lower minor bleeding incidence when compared with CDT alone (4.2 vs. 31.3%, p < .05). Conclusions: ART or CDT alone as the first-line ET for IVCF-related thrombosis has comparable outcomes but with different adverse event profiles. Both modalities are safe and effective in patients with massive IVCF-related thrombosis. (c) 2023 Asian Surgical Association and Taiwan Robotic Surgery Association. Publishing services by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/ licenses/by-nc-nd/4.0/).
引用
收藏
页码:263 / 268
页数:6
相关论文
共 4 条
  • [1] A better inferior vena cava filter retrieval rate: A retrospective study in a single-center institution
    Cao, Pengkai
    Li, Yunsong
    Liu, Xiangdong
    Li, Liang
    Li, Haitao
    Zhang, Xianchao
    Hao, Qingchun
    Zhang, Yanrong
    PHLEBOLOGY, 2020, 35 (06) : 424 - 429
  • [2] Comparing anticoagulant therapy alone, anticoagulant therapy in combination with catheter-directed thrombolysis, and anticoagulant therapy in combination with pharmacomechanical catheter-directed thrombolysis in the patients with optional inferior vena cava filter-related thrombosis: A single-center retrospective study
    Li, Zhaoyang
    Duan, Zhicheng
    Yang, Huitang
    Li, Meng
    Cai, Yandong
    Jiang, Zhan
    Fan, Guoju
    Wang, Kaiqiang
    Chen, Bo
    Zhang, Hongwei
    Li, Yankui
    VASCULAR, 2024,
  • [3] Evaluation of nonpermanent inferior vena cava filter placement in patients with deep venous thrombosis after lower extremity fracture: A single-center retrospective study
    Pan, Ye
    Zhao, Jun
    Mei, Jiacai
    Shao, Mingzhe
    Zhang, Jian
    Wu, Haisheng
    PHLEBOLOGY, 2016, 31 (08) : 564 - 572
  • [4] Factors Associated with Advanced Inferior Vena Cava Filter Removals: A Single-Center Retrospective Study of 203 Patients Over 7 Years
    Dowell, Joshua D.
    Wagner, Daniel
    Elliott, Eric
    Yildiz, Vedat O.
    Pan, Xueliang
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2016, 39 (02) : 218 - 226