Synergistic effects of web reinforcement and hybrid fibres on shear performance of continuous deep beams with unsymmetrical web openings

被引:1
作者
Fan, Shengxin [1 ,2 ]
Du, Panwei [2 ]
Tan, Kang Hai [2 ]
机构
[1] Shenzhen Univ, Coll Civil & Transportat Engn, Guangdong Prov Key Lab Durabil Marine Civil Engn, Key Lab Durabil Civil Engn Shenzhen, Shenzhen 518060, Peoples R China
[2] Nanyang Technol Univ, Dept Civil & Environm Engn, Singapore 639798, Singapore
基金
新加坡国家研究基金会;
关键词
Continuity; Deep beam; Web openings; Shear reinforcement; Hybrid fibres; LOAD-CAPACITY; TIE MODEL; BEHAVIOR; STRUT; PREDICTIONS; TESTS; SPAN;
D O I
10.1016/j.engstruct.2023.117129
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Application of fibre-reinforced concrete or novel web reinforcement detailing could be an effective way to enhance structural behaviour of continuous deep beams with web openings. However, there are very few experimental works studying the synergistic effects of these two methods. Therefore, an experimental programme is introduced in this paper to study synergistic effects of shear reinforcement and hybrid fibres on shear strength of nine double-span deep beams with unsymmetrical web openings (denoted as pierced span). The test specimens were designed to consist of a pierced beam span with a web opening and an adjacent solid beam span. The spans with openings were designed with different shear reinforcement configurations. It was experimentally shown that provision of sufficient web steels above and below web openings has the most important and beneficial effect on ultimate shear strength of the pierced spans. Besides, a tailored steel reinforcing method was also proposed that is capable of improving strut capacity near the web opening. In addition, adoption of hybrid fibre reinforcement led to enhanced crack-opening resistance, ultimate shear strength and shear deformation. Based on the research outcomes, it was recommended to adopt the proposed detailing method or fibre reinforcement dosage for shear strength enhancement of continuous deep beams with web openings. Furthermore, an analytical model was adopted to the shear strength of continuous deep beams accounting for web openings, steel stirrups, and hybrid fibres, which yielded safe predictions.
引用
收藏
页数:16
相关论文
共 29 条
  • [1] Reinforcing struts and ties in concrete continuous deep beams
    Abdul-Razzaq, Khattab Saleem
    Jalil, Ali Mustafa
    Dawood, Asala Asaad
    [J]. ENGINEERING STRUCTURES, 2021, 240
  • [2] [Anonymous], 2019, Building Code Requirements for Structural Concrete and Commentary, DOI [10.14359/51716937, DOI 10.14359/51716937]
  • [3] [Anonymous], 2005, EN 14651:2005+A1:2007
  • [4] Ashour AF, 1997, ACI STRUCT J, V94, P3
  • [5] Ashour AF, 2000, ACI STRUCT J, V97, P418
  • [6] Behaviour of concrete deep beams with openings and low shear span-to-depth ratio
    Campione, Giuseppe
    Minafo, Giovanni
    [J]. ENGINEERING STRUCTURES, 2012, 41 : 294 - 306
  • [7] Shear Strength of Reinforced Concrete Simple and Continuous Deep Beams
    Chen, Hui
    Yi, Wei-Jian
    Ma, Zhongguo John
    Hwang, Hyeon-Jong
    [J]. ACI STRUCTURAL JOURNAL, 2019, 116 (06) : 31 - 40
  • [8] Shear resistant capacity of steel fibres reinforced concrete deep beams: An experimental investigation and a new prediction model
    Dang, Tung D.
    Tran, Duong T.
    Nguyen-Minh, Long
    Nassif, Ayman Y.
    [J]. STRUCTURES, 2021, 33 : 2284 - 2300
  • [9] Fire behaviour and design of hybrid fibre reinforced high-performance concrete columns subjected to uniaxial bending
    Du, Panwei
    Yang, Yaowen
    Tan, Kang Hai
    [J]. ENGINEERING STRUCTURES, 2022, 251
  • [10] Analytical modelling of high strength concrete columns under ambient and fire conditions
    Du, Panwei
    Yang, Yaowen
    Tan, Kang Hai
    [J]. ENGINEERING STRUCTURES, 2021, 247