A numerical study of battery thermal management system with square spiral ring-shaped liquid cooling plate

被引:19
|
作者
Luo, Weiming [1 ]
Li, Haonan [1 ]
Chu, Tianying [1 ]
Chen, Jian [1 ]
Li, Chuanchang [1 ]
Huang, Simin [2 ]
Wu, Weixiong [3 ]
Lv, Youfu [1 ]
机构
[1] Changsha Univ Sci & Technol, Sch Energy & Power Engn, Changsha, Peoples R China
[2] Dongguan Univ Technol, Guangdong Prov Key Lab Distributed Energy Syst, Dongguan, Peoples R China
[3] Jinan Univ, Energy & Elect Res Ctr, Zhuhai, Peoples R China
关键词
Lithium -ion batteries; Battery thermal management; Mini-channel liquid cooling plate; Square spiral ring-shaped; PERFORMANCE; DESIGN;
D O I
10.1016/j.tsep.2023.102120
中图分类号
O414.1 [热力学];
学科分类号
摘要
The battery thermal management system is critical to the operating safety of power batteries. To alleviate the temperature gradient effect caused by the high local temperature of the battery, a centrally dispersed squarespiral-ring (SSR) mini-channel liquid cooling plate is designed for power batteries in this study. Through the simplification of the battery model, this liquid cooling plate battery thermal management system is investigated numerically. The effects of the number of SSR channel laps, channel width, channel bend radius and inlet mass flow rate on the temperature characteristics of the battery and coolant pressure drop are investigated. The results indicate that increasing the SSR channel laps and narrowing the channel width have a beneficial role in improving the battery and liquid cooling plate temperature distribution. The maximum battery temperature can be significantly dropped and the uniformity of battery temperature distribution can be considerably improved by enhancing the inlet mass flow rate. Moreover, additional branch channels could further improve the uniformity of the temperature distribution and the gradient effect of the battery. The maximum temperature decreases to 33.63 degrees C and the maximum temperature difference reduces to 6.45 degrees C during the 2C discharge process at a temperature of 25 degrees C. Furthermore, the SSR liquid cooling plate with a 5 mm-wide branch channel enables lower maximum battery temperatures and better temperature uniformity with lower pump power consumption than the existing serpentine plate. All these results and evidence provide an option for the development of novel minichannel liquid cooling plates for battery thermal management.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Numerical investigation on a lithium ion battery thermal management utilizing a serpentine-channel liquid cooling plate exchanger
    Sheng, Lei
    Su, Lin
    Zhang, Hua
    Li, Kang
    Fang, Yidong
    Ye, Wen
    Fang, Yu
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 141 : 658 - 668
  • [22] Performance of liquid cooling battery thermal management system in vibration environment
    Yin, Bin
    Zuo, Shuguang
    Xu, Yulin
    Chen, Shengpeng
    JOURNAL OF ENERGY STORAGE, 2022, 53
  • [23] Research on battery thermal management system based on liquid cooling plate with honeycomb-like flow channel
    Zhao, Ding
    Lei, Zhiguo
    An, Chao
    APPLIED THERMAL ENGINEERING, 2023, 218
  • [24] Numerical study on a novel thermal management system coupling immersion cooling with cooling tubes for power battery modules
    Zou, Zhiyang
    Xie, Jiekai
    Luo, Yunjun
    Zhang, Guoqing
    Yang, Xiaoqing
    JOURNAL OF ENERGY STORAGE, 2024, 83
  • [25] Performance analysis of liquid cooling battery thermal management system in different cooling cases
    Li, Ming
    Ma, Shiming
    Jin, Hui
    Wang, Rujin
    Jiang, Yan
    JOURNAL OF ENERGY STORAGE, 2023, 72
  • [26] Numerical study of a novel battery thermal management system coupled with heat pipe and cold plate
    Fang, Hui
    Liu, Changhui
    Zhang, Xuan
    Rao, Zhonghao
    APPLIED THERMAL ENGINEERING, 2024, 256
  • [27] Numerical Analysis on the Cooling Performance of the Battery Thermal Management System Using U-Shaped Flat Heat Pipe
    Dong, Xinyi
    Dai, Yijia
    Shao, Zhixiong
    Fu, Zaiguo
    Zhu, Qunzhi
    COMPUTATIONAL AND EXPERIMENTAL SIMULATIONS IN ENGINEERING, ICCES 2024-VOL 2, 2025, 173 : 331 - 349
  • [28] Liquid cooling plate with drop-shaped deflectors based on Coanda Effect-For Li-ion battery thermal management
    Zhao, Ding
    An, Chao
    Lei, Zhiguo
    JOURNAL OF ENERGY STORAGE, 2023, 70
  • [29] Numerical investigations on liquid cooling plate partially filled with porous medium for thermal management of lithium-ion battery pack
    Fu, Zhiao
    Zuo, Wei
    Li, Qingqing
    Zhou, Kun
    Huang, Yuhan
    Li, Yawei
    ENERGY, 2024, 313
  • [30] A simple cooling structure with precisely-tailored liquid cooling plate for thermal management of large battery module
    Xie, Jiekai
    Wang, Ye
    He, Shuming
    Zhang, Guoqing
    Liu, Xiangyun
    Yang, Xiaoqing
    APPLIED THERMAL ENGINEERING, 2022, 212