摘要
Seismic-resilient buildings are increasingly designed following low-damage and free-from-damage design strategies that aim to protect the structure's primary load-bearing systems under ultimate-level seismic loads. With this scope, damping devices are located in accessible and easy-to-inspect sites within the main structural frames where the damage concentrates, allowing the primary structure to remain mostly undamaged or easily repairable after a severe earthquake. This paper analyses the effects of friction-damping devices in structural joints of RC buildings endowed with hybrid steel-trussed concrete beams (HSTCBs) and standard RC columns. The study proposes innovative solutions to be adopted into RC moment-resisting frames (MRFs) at beam-to-column connections (BCCs) and column-base connections (CBCs). The cyclic behaviour of the joint is analysed through 3D finite element models, while pushover and non-linear time history analyses are performed on simple two-storey and two-span MRFs endowed with the proposed devices. The main results show that the BCC endowed with curved slotted holes and Perfobond connectors is the most effective in preventing the damage that might occur in beam, column, and joint, and it is adequate to guarantee good dissipative properties. For CBCs, the results showed that the re-centering system with friction pads is the most effective in containing the peak and residual drifts, preventing the plasticization of the column base.
引用
收藏
页数:16
相关论文
共 41 条
  • [1] Abaqus, 2016, AB VERS 2016
  • [2] [Anonymous], 2005, EN 1993-1-8
  • [3] [Anonymous], 2013, ACI Committee 374
  • [4] [Anonymous], 2022, 722 ASCESEI
  • [5] Computational Study of Failure of Hybrid Steel Trussed Concrete Beams
    Ballarini, Roberto
    La Mendola, Lidia
    Le, Jia-Liang
    Monaco, Alessia
    [J]. JOURNAL OF STRUCTURAL ENGINEERING, 2017, 143 (08)
  • [6] Combination of modal responses consistent with seismic input representation
    Cacciola, P
    Colajanni, P
    Muscolino, G
    [J]. JOURNAL OF STRUCTURAL ENGINEERING, 2004, 130 (01) : 47 - 55
  • [7] An experimental, numerical and analytical study of hybrid RC-encased steel joist beams subjected to shear
    Chisari, Corrado
    Amadio, Claudio
    [J]. ENGINEERING STRUCTURES, 2014, 61 : 84 - 98
  • [8] Friction-based beam-to-column connection for low-damage RC frames with hybrid trussed beams
    Colajanni, Piero
    Pagnotta, Salvatore
    [J]. STEEL AND COMPOSITE STRUCTURES, 2022, 45 (02) : 231 - 248
  • [9] Seismic Performance of Earthquake-Resilient RC Frames Made with HSTC Beams and Friction Damper Devices
    Colajanni, Piero
    La Mendola, Lidia
    Monaco, Alessia
    Pagnotta, Salvatore
    [J]. JOURNAL OF EARTHQUAKE ENGINEERING, 2022, 26 (15) : 7787 - 7813
  • [10] Design of RC joints equipped with hybrid trussed beams and friction dampers
    Colajanni, Piero
    La Mendola, Lidia
    Monaco, Alessia
    Pagnotta, Salvatore
    [J]. ENGINEERING STRUCTURES, 2021, 227