A single-turn rotating coil magnetic center calibration system designed for high energy photon source

被引:2
作者
Zhang, Luyan [1 ]
Han, Yuanying [1 ]
Dong, Lan [1 ,2 ]
Wang, Tong [1 ,2 ]
Ke, Zhiyong [1 ,2 ]
Wang, Xiaolong [1 ,2 ]
Men, Lingling [1 ,2 ]
Yan, Luping [1 ]
Lu, Shang [1 ]
Liu, Xiaoyang [1 ]
Yan, Haoyue [1 ]
机构
[1] Chinese Acad Sci, Inst High Energy Phys, Beijing 100049, Peoples R China
[2] Spallat Neutron Source Sci Ctr SNSSC, Dongguan 523803, Peoples R China
基金
中国国家自然科学基金;
关键词
synchrotron light source; magnetic field; magnetic center measurement;
D O I
10.1088/1361-6501/accebc
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
To ensure high-precision alignment of large quantities of magnets in Chinese high energy photon source, a high magnetic center measurement efficiency is required. To achieve this, a unique single-turn rotating coil magnetic center calibration system was designed, which simplifies the traditional multi-turn compensated coil with two sets of windings that can be connected. This design reduces measurement time significantly while increasing precision by incorporating a three-coordinate measuring machine. The study presents the system's general design, mathematical theory, and test results. Tests replacing the coil and magnets and realigning them demonstrated that the precision and measurement efficiency meet the design requirements. The displacement between the magnetic and mechanical axes was within 20 mu m, indicating good performance of the well-fabricated and tested ultra-high gradient quadrupole magnet. The optimized rotating coil system design reduces the entire procedure, including magnet installation and alignment, magnetic axis measurement, and magnetic center extraction to fixed points on the magnet, to only a few hours. Several magnets participating in pre-alignment were measured, and tests and practical operation resulted in small magnetic center displacements.
引用
收藏
页数:12
相关论文
共 12 条
[1]  
Jain A.K., 2001, US PARTICLE ACCELERA
[2]  
[彭全岭 Peng Quanling], 2010, [原子能科学技术, Atomic Energy Science and Technology], V44, P617
[3]  
Peng Quanling, 2008, Computer Measurement & Control, V16, P285
[4]  
Penicka J M., 2016, PROC INT WORKSHOP AC
[5]  
Tanabe J T., 2005, Iron Dominated Electromagnets: Design, Fabrication, Assembly and Measurements, Vvol 8, pp 213
[6]  
Turner S., 1998, PROCEEDINGS, V95
[7]   Assessing the economic life of rail using a stochastic analysis of failures [J].
Zhao, J. ;
Chan, A. H. C. ;
Roberts, C. ;
Stirling, A. B. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART F-JOURNAL OF RAIL AND RAPID TRANSIT, 2006, 220 (02) :103-111
[8]  
Zhou J, 2018, HIGH POWER LASER PAR, V30
[9]   AC magnetic field measurement of CSNS/RCS quadrupole prototype [J].
Zhou, J. X. ;
Li, L. ;
Yin, B. G. ;
Deng, C. D. ;
Kang, W. ;
Fu, S. N. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 654 (01) :72-75
[10]   A harmonic coil measurement system based on a dynamic signal acquisition device [J].
Zhou, J. X. ;
Li, L. ;
Yin, B. G. ;
Deng, C. D. ;
Kang, W. ;
Chen, Y. ;
Zhang, Z. ;
Fu, S. N. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 624 (03) :549-553