Research on the cross-contamination in the confined conference room with the radiant floor heating system integrated with the down-supply ventilation

被引:4
作者
Wu, Jie [1 ]
Xu, Liang [1 ]
Shen, JingHua [1 ]
机构
[1] Soochow Univ, Sch Architecture, Suzhou, Peoples R China
基金
国家重点研发计划;
关键词
Down -supply ventilation; Radiant floor system; Cross; -contamination; Envelope insulation; AIR-DISTRIBUTION; DISPLACEMENT VENTILATION; PERSONALIZED VENTILATION; ENCLOSED ENVIRONMENTS; HOSPITAL WARD; TRACER GAS; DISPERSION; PARTICLES; INFECTION; PERFORMANCE;
D O I
10.1016/j.heliyon.2023.e14389
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The performance of a confined conference room under radiant heat floor combined with down -supply ventilation (RFDS) is investigated. The purpose of the study is to reveal the mechanism of indoor contaminants transmission from infected person and to protect the occupants. The exhaled contaminant dispersion was simulated using a CFD model and experimentally validated in an office with the down-supply ventilation (DS). The effects of radiant floor (RF) combined with down-supply ventilation on airflow and contaminant distribution in the room was evaluated with regard to different RF temperatures and inlet velocities. The influence of downdraft from the envelope on the airflow pattern of the room is also discussed. It is proved that the exposure risk of pollutants can be reduced by strengthening the insulation of the envelope. The simulation results showed that the proposed RFDS system could significantly reduce the level of exposure to contaminants in the breathing zone (BZ) of occupants. In this research case, the RFDS reduced the average exposure rates by more than 50% relative to the case with the only down-supply warm air heating. Furthermore, With improved envelope insulation, the probability of infection can be reduced by more than 80% only by avoiding a simultaneous inlet velocity of 0.3 m/s at RF temperatures no less than 27 degrees C. The results suggested an improved fresh air heating mode for passive ultra-low energy consumption buildings with good thermal insulation and air tightness.
引用
收藏
页数:18
相关论文
共 75 条
[1]   Numerical investigation of aerosol transport in a classroom with relevance to COVID-19 [J].
Abuhegazy, Mohamed ;
Talaat, Khaled ;
Anderoglu, Osman ;
Poroseva, Svetlana, V .
PHYSICS OF FLUIDS, 2020, 32 (10)
[2]   Large eddy simulation of wind-induced interunit dispersion around multistory buildings [J].
Ai, Z. T. ;
Mak, C. M. .
INDOOR AIR, 2016, 26 (02) :259-273
[3]   Tracer gas is a suitable surrogate of exhaled droplet nuclei for studying airborne transmission in the built environment [J].
Ai, Zhengtao ;
Mak, Cheuk Ming ;
Gao, Naiping ;
Niu, Jianlei .
BUILDING SIMULATION, 2020, 13 (03) :489-496
[4]   Effectiveness of intermittent personalized ventilation in protecting occupant from indoor particles [J].
Al Assaad, Douaa ;
Habchi, Carine ;
Ghali, Kamel ;
Ghaddar, Nesreen .
BUILDING AND ENVIRONMENT, 2018, 128 :22-32
[5]  
Ashrae A., 2017, ASHRAE Standard 55: Thermal Environmental Conditions for Human Occupancy
[6]  
Babiak J., 2007, LOW TEMPERATURE HEAT
[7]   A comparison between tracer gas and aerosol particles distribution indoors: The impact of ventilation rate, interaction of airflows, and presence of objects [J].
Bivolarova, M. ;
Ondracek, J. ;
Melikov, A. ;
Zdimal, V. .
INDOOR AIR, 2017, 27 (06) :1201-1212
[8]   Performances of low temperature radiant heating systems [J].
Bojic, Milorad ;
Cvetkovic, Dragan ;
Marjanovic, Vesna ;
Blagojevic, Mirko ;
Djordjevic, Zorica .
ENERGY AND BUILDINGS, 2013, 61 :233-238
[9]  
BuliLska Anna., 2017, COMPUTER ASSISTED ME, V22, P213
[10]   Estimation of airborne viral emission: Quanta emission rate of SARS-CoV-2 for infection risk assessment [J].
Buonanno, G. ;
Stabile, L. ;
Morawska, L. .
ENVIRONMENT INTERNATIONAL, 2020, 141