Evaluating an advanced double intravenous vasopressor automated system to treat hypotension during spinal anesthesia for cesarean delivery: a randomized controlled trial

被引:1
|
作者
Tan, Hon Sen [1 ,2 ]
Nagarajan, Singaraselvan [1 ,2 ]
Chan, Jason Ju In [1 ,2 ]
Tan, Chin Wen [1 ,2 ]
Sultana, Rehena [3 ]
Sia, Alex Tiong Heng [1 ,2 ]
Sng, Ban Leong [1 ,2 ]
机构
[1] KK Womens & Childrens Hosp, Dept Womens Anesthesia, Singapore, Singapore
[2] Duke NUS Med Sch, Anesthesiol & Perioperat Sci Acad Clin Program, Singapore, Singapore
[3] Duke NUS Med Sch, Ctr Quantitat Med, Singapore, Singapore
关键词
Anesthesia; Cesarean delivery; Ephedrine; Hemodynamics; Hypotension; Phenylephrine; COMPUTER-CONTROLLED INFUSION; BLOOD-PRESSURE; HEMODYNAMIC STABILITY; PHENYLEPHRINE; SECTION; MAINTENANCE; NEXFIN;
D O I
10.1186/s12871-023-01992-7
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BackgroundThe optimal treatment of hypotension during spinal anaesthesia is uncertain. A novel double intravenous vasopressor automated (DIVA) system reduces hypotension compared to standard care, and was subsequently modified to an advanced-DIVA (ADIVA) system. The primary objective was to compare ADIVA versus DIVA on incidence of hypotension (systolic BP (SBP) < 80% baseline).MethodsWe conducted a randomized-controlled trial in women undergoing elective cesarean delivery under spinal anesthesia. SBP and heart rate were measured continuously using a Nexfin monitor. ADIVA delivered 25 mu g phenylephrine (heart rate > 60 beats.min(-1)) or 2 mg ephedrine (heart rate < 60 beats.min(-1)) at SBP 90 to 110% of baseline, 50 mu g phenylephrine or 4 mg ephedrine at SBP 80 to 90%, and 75 mu g phenylephrine or 6 mg ephedrine at SBP < 80%. ADIVA calculated the trend of SBP; vasopressors were administered rapidly if SBP trended downward, or 30 s if SBP trended upward. In contrast, DIVA delivered 25 mu g phenylephrine or 2 mg ephedrine at SBP 90 to 100% of baseline, and 50 mu g phenylephrine or 4 mg ephedrine at SBP < 90%. Boluses were followed by a 10-s lockout. Other outcomes included hypertension (SBP > 120% baseline), vasopressor consumption, clinical outcomes, and performance measures from spinal anesthesia to fetal delivery.ResultsWe analyzed 94 parturients (ADIVA: n = 46, DIVA: n = 48), with no difference in the incidence of hypotension between ADIVA (78.3%) and DIVA (83.3%, p = 0.677). ADIVA had significantly higher proportion of hypotensive SBP readings, lower phenylephrine consumption and higher umbilical arterial pH. There was no difference in hypertension, bradycardia, ephedrine consumption, intravenous fluid volume, nausea/vomiting, Apgar scores, and umbilical venous pH or lactate. ADIVA maintained SBP higher above baseline with greater fluctuation than DIVA. ConclusionADIVA was associated with a greater proportion of hypotensive SBP readings, reduced phenylephrine consumption, and increased umbilical arterial pH than DIVA. Further research is needed to determine the optimal method of vasopressor delivery in parturients undergoing cesarean delivery.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Intravenous dexmedetomidine for the treatment of shivering during Cesarean delivery under neuraxial anesthesia: a randomized-controlled trial
    Lamontagne, Christina
    Lesage, Sandra
    Villeneuve, Edith
    Lidzborski, Elsa
    Derstenfeld, Alex
    Crochetiere, Chantal
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2019, 66 (07): : 762 - 771
  • [22] Comparison of Intermittent Intravenous Boluses of Phenylephrine and Norepinephrine to Prevent and Treat Spinal-Induced Hypotension in Cesarean Deliveries: Randomized Controlled Trial
    Sharkey, Aidan M.
    Siddiqui, Naveed
    Downey, Kristi
    Ye, Xiang Y.
    Guevara, Jennifer
    Carvalho, Jose C. A.
    ANESTHESIA AND ANALGESIA, 2019, 129 (05): : 1312 - 1318
  • [23] Comparison of double intravenous vasopressor automated system using nexfin versus manual vasopressor bolus administration for maintenance of haemodynamic stability during spinal anaesthesia for caesarean delivery: A randomised double-blind controlled trial
    Sng, Ban Leong
    Du, Wei
    Lee, Man Xin
    Ithnin, Farida
    Mathur, Deepak
    Leong, Wan Ling
    Sultana, Rehena
    Han, Nian-Lin R.
    Sia, Alex Tiong Heng
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2018, 35 (05) : 390 - 397
  • [24] Comparison of Continuous Infusion of Epinephrine and Phenylephrine on Hemodynamics During Spinal Anesthesia for Cesarean Delivery: A Randomized Controlled Trial
    Wang, Y. B.
    Yang, Z. Y.
    Zhang, W. P.
    CLINICAL THERAPEUTICS, 2020, 42 (10) : 2001 - 2009
  • [25] Closed-loop double-vasopressor automated system to treat hypotension during spinal anaesthesia for caesarean section: a preliminary study
    Sia, A. T. H.
    Tan, H. S.
    Sng, B. L.
    ANAESTHESIA, 2012, 67 (12) : 1348 - 1355
  • [26] ONDANSETRON DOSE NOT ATTENUATES HYPOTENSION IN PATIENTS UNDERGOING ELECTIVE CESAREAN DELIVERY UNDER SPINAL ANESTHESIA: A DOUBLE-BLINDED, PLACEBO-CONTROLLED RANDOMIZED TRIAL
    Terkawi, A. S.
    Mehta, S. H.
    Hackworth, J. H.
    Tiouririne, M.
    ANESTHESIA AND ANALGESIA, 2014, 118 : S194 - S194
  • [27] A quantitative, systematic review of randomized controlled trials of ephedrine versus phenylephrine for the management of hypotension during spinal anesthesia for cesarean delivery
    Lee, A
    Kee, WDN
    Gin, T
    ANESTHESIA AND ANALGESIA, 2002, 94 (04): : 920 - 926
  • [28] Epinephrine vs. phenylephrine infusion for prophylaxis against maternal hypotension after spinal anesthesia for cesarean delivery: a randomized controlled trial
    Hassabelnaby, Yasmin S.
    Hasanin, Ahmed M.
    Shamardal, Mohamed
    Mostafa, Maha
    Zaki, Rana M.
    Elsherbiny, Mona
    Refaat, Sherin
    JOURNAL OF ANESTHESIA, 2024, 38 (04) : 500 - 507
  • [30] Effects of isothermic crystalloid coload on maternal hypotension and fetal outcomes during spinal anesthesia for cesarean section: A randomized controlled trial
    Canturk, Mehmet
    Canturk, Fusun Karbancioglu
    TAIWANESE JOURNAL OF OBSTETRICS & GYNECOLOGY, 2019, 58 (03): : 428 - 433