A robust treatment planning approach for chest motion in postmastectomy chest wall intensity modulated radiation therapy

被引:2
|
作者
Miyasaka, Yuya [1 ]
Ono, Takuya [1 ]
Chai, Hongbo [1 ]
Souda, Hikaru [1 ]
Lee, Sung Hyun [1 ]
Ishizawa, Miyu [1 ]
Akamatsu, Hiroko [2 ]
Sato, Hiraku [2 ]
Iwai, Takeo [1 ]
机构
[1] Yamagata Univ, Grad Sch Med Sci, Dept Heavy Particle Med Sci, Yamagata, Japan
[2] Yamagata Univ, Fac Med, Dept Radiol, Yamagata, Japan
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2024年 / 25卷 / 01期
关键词
IMRT; PMRT; respiratory motion; robust optimization; setup error; ARC THERAPY; RADIOTHERAPY; BREAST; OPTIMIZATION; IMRT; IRRADIATION; NODES; VMAT;
D O I
10.1002/acm2.14217
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Chest wall postmastectomy radiation therapy (PMRT) should consider the effects of chest wall respiratory motion. The purpose of this study is to evaluate the effectiveness of robustness planning intensity modulated radiation therapy (IMRT) for respiratory movement, considering respiratory motion as a setup error.Material and methods: This study analyzed 20 patients who underwent PMRT (10 left and 10 right chest walls). The following three treatment plans were created for each case and compared. The treatment plans are a planning target volume (PTV) plan (PP) that covers the PTV within the body contour with the prescribed dose, a virtual bolus plan (VP) that sets a virtual bolus in contact with the body surface and prescribing the dose that includes the PTV outside the body contour, and a robust plan (RP) that considers respiratory movement as a setup uncertainty and performs robust optimization. The isocenter was shifted to reproduce the chest wall motion pattern and the doses were recalculated for comparison for each treatment plan.Result: No significant difference was found between the PP and the RP in terms of the tumor dose in the treatment plan. In contrast, VP had 3.5% higher PTV Dmax and 5.5% lower PTV V95% than RP (p < 0.001). The RP demonstrated significantly higher lung V20Gy and Dmean by 1.4% and 0.4 Gy, respectively, than the PP. The RP showed smaller changes in dose distribution affected by chest wall motion and significantly higher tumor dose coverage than the PP and VP.Conclusion: We revealed that the RP demonstrated comparable tumor doses to the PP in treatment planning and was robust for respiratory motion compared to both the PP and the VP. However, the organ at risk dose in the RP was slightly higher; therefore, its clinical use should be carefully considered.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Postmastectomy intensity modulation radiated therapy of chest wall and regional nodes Retrospective analysis of the performance and complications up for 5 years
    Wang, Qiong
    Jie, Wuyun
    Liang, Zhiwen
    Wu, Hongge
    Cheng, Jing
    MEDICINE, 2017, 96 (39)
  • [2] Treatment planning comparison of electron arc therapy and photon intensity modulated radiotherapy for Askin's tumor of chest wall
    Jamema, Swamidas V.
    Sharma, Pramod K.
    Laskar, Siddhartha
    Deshpande, Deepak D.
    Shrivastava, Shyam K.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 (03) : 257 - 265
  • [3] A robust planning approach for respiratory motion in accelerated partial breast irradiation using volumetric modulated arc therapy
    Yamauchi, Ryohei
    Tomita, Fumihiro
    Ishikura, Satoshi
    JOURNAL OF RADIATION RESEARCH, 2025, : 185 - 195
  • [4] EVALUATION OF A THERMOPLASTIC IMMOBILIZATION SYSTEM FOR BREAST AND CHEST WALL RADIATION THERAPY
    Strydhorst, Jared H.
    Caudrelier, Jean-Michel
    Clark, Brenda G.
    Montgomery, Lynn A.
    Fox, Greg
    MacPherson, Miller S.
    MEDICAL DOSIMETRY, 2011, 36 (01) : 81 - 84
  • [5] Intensity modulated proton therapy for postmastectomy radiation of bilateral implant reconstructed breasts: A treatment planning study
    Jimenez, Rachel B.
    Goma, Carles
    Nyamwanda, Jacqueline
    Kooy, Hanne M.
    Halabi, Tarek
    Napolitano, Brian N.
    McBride, Sean M.
    Taghian, Alphonse G.
    Lu, Hsiao-Ming
    MacDonald, Shannon M.
    RADIOTHERAPY AND ONCOLOGY, 2013, 107 (02) : 213 - 217
  • [6] Modulated Arc Therapy for hippocampal-avoidance whole brain radiation therapy: planning comparison with intensity modulated Radiation Therapy
    Martin-Tovar, E. A.
    Badillo-Alvarado, A. H.
    Cocom-Poot, L. E.
    Gaxiola-Sosa, J. L.
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2024, 63 (03) : 443 - 454
  • [7] Automated Intensity Modulated Radiation Therapy Treatment Planning for Cervical Cancer Based on Convolution Neural Network
    Chen Jihong
    Bai Penggang
    Zhang Xiuchun
    Chen Kaiqiang
    Chen Wenjuan
    Dai Yitao
    Qian Jiewei
    Quan Kerun
    Zhong Jing
    Wu Tianming
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2020, 19
  • [8] Multistage stochastic fractionated intensity modulated radiation therapy planning
    Bodur, Merve
    Cevik, Mucahit
    Cire, Andre A.
    Ruschin, Mark
    Wang, Juyoung
    COMPUTERS & OPERATIONS RESEARCH, 2023, 160
  • [9] Potential gains for irradiation of chest wall and regional nodes with intensity modulated radiotherapy
    Krueger, EA
    Fraass, BA
    McShan, DL
    Marsh, R
    Pierce, LJ
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (04): : 1023 - 1037
  • [10] On the value of a multistage optimization approach for intensity-modulated radiation therapy planning*
    Wood, Doran
    Cetinkaya, Sila
    Gangammanavar, Harsha
    Lu, Weigo
    Wang, Jing
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (14)