Spatial resolution, noise properties, and detectability index of a deep learning reconstruction algorithm for dual-energy CT of the abdomen

被引:7
作者
Thor, Daniel [1 ,2 ]
Titternes, Rebecca [1 ,3 ]
Poludniowski, Gavin [1 ,3 ,4 ]
机构
[1] Karolinska Univ Hosp, Dept Med Radiat Phys & Nucl Med, Stockholm, Sweden
[2] Karolinska Inst, Dept Oncol Pathol, Stockholm, Sweden
[3] Karolinska Inst, Dept Clin Sci Intervent & Technol, Stockholm, Sweden
[4] Karolinska Univ Hosp, Med Radiat Phys & Nucl Med, SE-17176 Stockholm, Sweden
关键词
DECT; deep learning image reconstruction; image quality; FILTERED BACK-PROJECTION; RADIATION-DOSE REDUCTION; ITERATIVE RECONSTRUCTION; IMAGE-RECONSTRUCTION; PERFORMANCE; CONTRAST; OPTIMIZATION;
D O I
10.1002/mp.16300
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundIterative reconstruction (IR) has increasingly replaced traditional reconstruction methods in computed tomography (CT). The next paradigm shift in image reconstruction is likely to come from artificial intelligence, with deep learning reconstruction (DLR) solutions already entering the clinic. An enduring disadvantage to IR has been a change in noise texture, which can affect diagnostic confidence. DLR has demonstrated the potential to overcome this issue and has recently become available for dual-energy CT. PurposeTo evaluate the spatial resolution, noise properties, and detectability index of a commercially available DLR algorithm for dual-energy CT of the abdomen and compare it to single-energy (SE) CT. MethodsAn oval 25 cm x 35 cm custom-made phantom was scanned on a GE Revolution CT scanner (GE Healthcare, Waukesha, WI) at two dose levels (13 and 5 mGy) and two iodine concentrations (8 and 2 mg/mL), using three typical abdominal scan protocols: dual-energy (DE), SE 80 kV (SE-80 kV) and SE 120 kV (SE-120 kV). Reconstructions were performed with three strengths of IR (ASiR-V: AR0%, AR50%, AR100%) and three strengths of DLR (TrueFidelity: low, medium, high). The DE acquisitions were reconstructed as mono-energetic images between 40 and 80 keV. The noise power spectrum (NPS), task transfer function (TTF), and detectability index (d') were determined for the reconstructions following the recommendations of AAPM Task Group 233. ResultsNoise magnitude reductions (relative to AR0%) for the SE protocols were on average (-29%, -21%) for (AR50%, TF-M), while for DE-70 keV were (-28%, -43%). There was less reduction in mean frequency (f(av)) for DLR than for IR, with similar results for SE and DE imaging. There was, however, a substantial change in the NPS shape when using DE with DLR, quantifiable by a marked reduction in the peak frequency (f(peak)) that was absent in SE mode. All protocols and reconstructions (including AR0%) exhibited slight to moderate shifts towards lower spatial frequencies at the lower dose (<12% in f(av)). Spatial resolution was consistently superior for DLR compared to IR for SE but not for DE. All protocols and reconstructions (including AR0%) showed decreased resolution with reduced dose and iodine concentration, with less decrease for DLR compared to IR. DLR displayed a higher d' than IR. The effect of energy was large: d' increased with lower keV, and SE-80 kV had higher d' than SE-120 kV. Using DE with DLR could provide higher d' than SE-80 kV at the higher dose but not at lower dose. ConclusionsDE imaging with DLR maintained spatial resolution and reduced noise magnitude while displaying less change in noise texture than IR. The d' was also higher with DLR than IR, suggesting superiority in detectability of iodinated contrast. Despite these trends being consistent with those previously established for SE imaging, there were some noteworthy differences. For DE imaging there was no improvement in resolution compared to IR and a change in noise texture. DE imaging with low keV and DLR had superior detectability to SE DLR at the high dose but was not better than SE-80 kV at low dose.
引用
收藏
页码:2775 / 2786
页数:12
相关论文
共 50 条
  • [21] Multi-channel convolutional analysis operator learning for dual-energy CT reconstruction
    Perelli, Alessandro
    Garcia, Suxer Alfonso
    Bousse, Alexandre
    Tasu, Jean-Pierre
    Efthimiadis, Nikolaos
    Visvikis, Dimitris
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (06)
  • [22] Virtual monochromatic images of dual-energy CT as an alternative to single-energy CT: performance comparison using a detectability index for different acquisition techniques
    Kawashima, Hiroki
    Ichikawa, Katsuhiro
    Ueta, Hiroshi
    Takata, Tadanori
    Mitsui, Wataru
    Nagata, Hiroji
    EUROPEAN RADIOLOGY, 2023, 33 (08) : 5752 - 5760
  • [23] Deep learning reconstruction CT for liver metastases: low-dose dual-energy vs standard-dose single-energy
    Lyu, Peijie
    Li, Zhen
    Chen, Yan
    Wang, Huixia
    Liu, Nana
    Liu, Jie
    Zhan, Pengchao
    Liu, Xing
    Shang, Bo
    Wang, Luotong
    Gao, Jianbo
    EUROPEAN RADIOLOGY, 2024, 34 (01) : 28 - 38
  • [24] The value of using a deep learning image reconstruction algorithm of thinner slice thickness to balance the image noise and spatial resolution in low-dose abdominal CT
    Wang, Huan
    Li, Xinyu
    Wang, Tianze
    Li, Jianying
    Sun, Tianze
    Chen, Lihong
    Cheng, Yannan
    Jia, Xiaoqian
    Niu, Xinyi
    Guo, Jianxin
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (03) : 1814 - 1824
  • [25] Low-KeV Virtual Monoenergetic Dual-Energy CT with Deep Learning Reconstruction for Assessing Hepatocellular Carcinoma
    Ota, Takashi
    Nakamoto, Atsushi
    Onishi, Hiromitsu
    Tsuboyama, Takahiro
    Matsumoto, Shohei
    Fukui, Hideyuki
    Kaketaka, Koki
    Honda, Toru
    Kiso, Kengo
    Tatsumi, Mitsuaki
    Tomiyama, Noriyuki
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2024, 44 (02) : 293 - 306
  • [26] Dual-energy CT of the pancreas: improved carcinoma-to-pancreas contrast with a noise-optimized monoenergetic reconstruction algorithm
    Frellesen, Claudia
    Fessler, Freia
    Hardie, Andrew D.
    Wichmann, Julian L.
    De Cecco, Carlo N.
    Schoepf, U. Joseph
    Kerl, J. Matthias
    Schulz, Boris
    Hammerstingl, Renate
    Vogl, Thomas J.
    Bauer, Ralf W.
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (11) : 2052 - 2058
  • [27] Improved overall image quality in low-dose dual-energy computed tomography enterography using deep-learning image reconstruction
    Lin, Xu
    Gao, Yankun
    Zhu, Chao
    Song, Jian
    Liu, Ling
    Li, Jianying
    Wu, Xingwang
    ABDOMINAL RADIOLOGY, 2024, 49 (09) : 2979 - 2987
  • [28] Iterative dynamic dual-energy CT algorithm in reducing statistical noise in multi-energy CT imaging
    Yao, Yidi
    Li, Liang
    Chen, Zhiqiang
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (01)
  • [29] Use of a Noise Optimized Monoenergetic Algorithm for Patient-Size Independent Selection of an Optimal Energy Level During Dual-Energy CT of the Pancreas
    Bellini, Davide
    Gupta, Sonia
    Ramirez-Giraldo, Juan Carlos
    Fu, Wanyi
    Stinnett, Sandra S.
    Patel, Bhavik
    Mileto, Achille
    Marin, Daniele
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2017, 41 (01) : 39 - 47
  • [30] Improving lesion conspicuity in abdominal dual-energy CT with deep learning image reconstruction: a prospective study with five readers
    Jingyu Zhong
    Lingyun Wang
    Hailin Shen
    Jianying Li
    Wei Lu
    Xiaomeng Shi
    Yue Xing
    Yangfan Hu
    Xiang Ge
    Defang Ding
    Fuhua Yan
    Lianjun Du
    Weiwu Yao
    Huan Zhang
    European Radiology, 2023, 33 : 5331 - 5343