Normative High-Resolution Pharyngeal Manometry: Impact of Age, Size of System, and Sex on Primary Metrics and Pressure Stability

被引:0
作者
Jones, Corinne A. [1 ,2 ,3 ]
Lagus, Jilliane F. [1 ]
Abdelhalim, Suzan M. [3 ]
Osborn, Caroline M. [1 ]
Colevas, Sophia M. [3 ]
Mcculloch, Timothy M. [3 ]
机构
[1] Univ Texas Austin, Moody Coll Commun, Dept Speech Language & Hearing Sci, Austin, TX USA
[2] Univ Texas Austin, Dell Med Sch, Dept Neurol, 1601 Trinity St,Bldg B,Stop Z0700, Austin, TX 78712 USA
[3] Univ WI Madison, Sch Med & Publ Hlth, Dept Surg, Div Otolaryngol Head & Neck Surg, K4-710 CSC,600 Highland Ave, Madison, WI 53792 USA
基金
美国国家卫生研究院;
关键词
Deglutition; High-resolution manometry; Aging; BOLUS VOLUME; SWALLOWING FUNCTION; TOPOGRAPHY; MODULATION;
D O I
10.1007/s00455-023-10647-1
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
There have been many reports of normative pharyngeal swallowing pressures using high-resolution pharyngeal manometry, but there is a fair amount of between-subject variance in reported pressure parameters. The purpose of this study was to put forward normative pharyngeal high-resolution manometry measures across the lifespan and investigate the effects of age, size of system, and sex. High-resolution pharyngeal manometry was performed on 98 healthy adults (43 males) between the ages 21 and 89. Pressure duration, maxima, integral, and within-individual variability metrics were averaged over 10 swallows of 10-ml thin liquid. Multiple linear and logistic regressions with model fitting were used to examine how pharyngeal pressures relate to age, pharyngeal size, and sex. Age was associated with tongue base maximum pressure, tongue base maximum variability, and upper esophageal sphincter-integrated relaxation pressure (F-3,F-92 = 6.69; p < 0.001; adjusted R-2 = 0.15). Pharyngeal area during bolus hold was associated with velopharynx integral (F-1,F-89 = 5.362; p = 0.02; adjusted R-2 = 0.05), and there was no significant model relating pharyngeal pressures to C2-C4 length (p < 0.05). Sex differences were best described by tongue base integral and hypopharynx maximum variability (chi(2) = 10.27; p = 0.006; pseudo R-2 = 0.14). Normative data reveal the distribution of swallow pressure metrics which need to be accounted for when addressing dysphagia patients, the importance of pressure interactions in normal swallow, and address the relative stability of swallow metrics with normal aging.
引用
收藏
页码:648 / 665
页数:18
相关论文
共 24 条
  • [11] Accuracy of High-Resolution Pharyngeal Manometry Metrics for Predicting Aspiration and Residue in Oropharyngeal Dysphagia Patients with Poor Pharyngeal Contractility
    Howell Henrian G. Bayona
    Nicole Pizzorni
    Jan Tack
    Ann Goeleven
    Taher Omari
    Nathalie Rommel
    Dysphagia, 2022, 37 : 1560 - 1575
  • [12] Accuracy of High-Resolution Pharyngeal Manometry Metrics for Predicting Aspiration and Residue in Oropharyngeal Dysphagia Patients with Poor Pharyngeal Contractility
    Bayona, Howell Henrian G.
    Pizzorni, Nicole
    Tack, Jan
    Goeleven, Ann
    Omari, Taher
    Rommel, Nathalie
    DYSPHAGIA, 2022, 37 (06) : 1560 - 1575
  • [13] Adequate Number of Swallows for Pharyngeal Pressure Measurement of a Subject using High-resolution Manometry
    Tsuyumu, Matsusato
    Hama, Takanori
    Kato, Takakuni
    Kojima, Hiromi
    INTERNATIONAL ARCHIVES OF OTORHINOLARYNGOLOGY, 2021, 25 (01) : 81 - 87
  • [14] Effect of Different Viscosities on Pharyngeal Pressure During Swallowing: A Study Using High-Resolution Manometry
    Park, Donghwi
    Shin, Cheol Min
    Ryu, Ju Seok
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2017, 98 (03): : 487 - 494
  • [15] High-Resolution Manometry of Pharyngeal Swallow Pressure Events Associated With Head Turn and Chin Tuck
    McCulloch, Timothy M.
    Hoffman, Matthew R.
    Ciucci, Michelle R.
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2010, 119 (06) : 369 - 376
  • [16] Determinants of pressure drift in Manoscan™ esophageal high-resolution manometry system
    Babaei, A.
    Lin, E. C.
    Szabo, A.
    Massey, B. T.
    NEUROGASTROENTEROLOGY AND MOTILITY, 2015, 27 (02) : 277 - 284
  • [17] Relationship Between Tongue Pressure and Pharyngeal Function Assessed Using High-Resolution Manometry in Older Dysphagia Patients with Sarcopenia: A Pilot Study
    Kunieda, Kenjiro
    Fujishima, Ichiro
    Wakabayashi, Hidetaka
    Ohno, Tomohisa
    Shigematsu, Takashi
    Itoda, Masataka
    Oshima, Fumiko
    Mori, Takashi
    Ogawa, Nami
    Ogawa, Sumito
    DYSPHAGIA, 2021, 36 (01) : 33 - 40
  • [18] Relationship Between Tongue Pressure and Pharyngeal Function Assessed Using High-Resolution Manometry in Older Dysphagia Patients with Sarcopenia: A Pilot Study
    Kenjiro Kunieda
    Ichiro Fujishima
    Hidetaka Wakabayashi
    Tomohisa Ohno
    Takashi Shigematsu
    Masataka Itoda
    Fumiko Oshima
    Takashi Mori
    Nami Ogawa
    Sumito Ogawa
    Dysphagia, 2021, 36 : 33 - 40
  • [19] Characterization and correction of pressure drift in the ManoScan™ high-resolution manometry system: In vitro and invivo
    Lamvik, K.
    Hernandez, E. Guiu
    Jones, R.
    Huckabee, M. -L.
    NEUROGASTROENTEROLOGY AND MOTILITY, 2016, 28 (05) : 732 - 742
  • [20] The Effects of Bolus Volume and Texture on Pharyngeal Pressure Events Using High-resolution Manometry and Its Comparison with Videofluoroscopic Swallowing Study
    Ryu, Ju Seok
    Park, Donghwi
    Oh, Yoongul
    Lee, Seok Tae
    Kang, Jin Young
    JOURNAL OF NEUROGASTROENTEROLOGY AND MOTILITY, 2016, 22 (02) : 231 - 239