共 8 条
Omnidirectional (Flexible) Ureteral Access Sheath: Safety, Efficacy, and Initial Experience Report
被引:12
作者:
Ding, Jie
[1
]
Su, Tingting
[2
]
Zhang, Xiangmin
[3
]
Qian, Subo
[1
]
Duan, Liujian
[1
]
Huang, Yunteng
[1
]
Chu, Jian
[3
,4
]
Zhang, Lin
[1
,5
]
Cao, Jianwei
[1
,5
]
Cui, Xingang
[1
,5
]
机构:
[1] Shanghai Jiao Tong Univ, Xinhua Hosp, Sch Med, Dept Urol, Shanghai, Peoples R China
[2] Shanghai Jiao Tong Univ, Xinhua Hosp, Sch Med, Dept Gen Surg, Shanghai, Peoples R China
[3] Shanghai Baoshan Luodian Hosp, Dept Urol, Baoshan, Shanghai, Peoples R China
[4] Shanghai Baoshan Luodian Hosp, Dept Urol, Baoshan 201908, Shanghai, Peoples R China
[5] Shanghai Jiao Tong Univ, Xinhua Hosp, Sch Med, Dept Urol, 1665 Kongjiang Rd, Shanghai 200092, Peoples R China
关键词:
ureteral access sheath;
omnidirectional;
flexible ureteroscopic lithotripsy;
deflection angle;
operation time;
single-session stone-free rate;
D O I:
10.1089/end.2023.0358
中图分类号:
R5 [内科学];
R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号:
1002 ;
100201 ;
摘要:
Background: Recently a novel omnidirectional (OD) ureteral access sheath (UAS) has been developed. By retrospectively reviewing and comparing the flexible ureteroscopic lithotripsy (FURL) cases in our institution with either a conventional Cook UAS or an OD UAS in the past year, we shared our experience of the safety, efficacy, and relevant issues on the usage of OD UAS. Materials and Methods: The medical history and surgery details of 199 patients with kidney stones or ureterojunctional stones who underwent FURL in Xinhua Hospital, including 61 Cook UAS and 138 OD UAS, were reviewed and compared. The maximal deflection angle was measured by steering four different types of ureteroscopes to bend the OD UAS in different states. Result: The deflection angle of OD UAS was similar to 110 degrees to 130 degrees free load, and 90 degrees to 130 degrees when loaded with different instruments. The stone burden and position were similar in two groups. Given a similar prestent ratio and operation time, the OD UAS group achieved a higher single-session stone-free rate (SFR) (63.9% vs 94.2%, p < 0.0001) at 1-month follow-up evaluated by a CT scan. Conclusion: OD UAS is a novel device with high safety and efficacy. The unique flexible design allows it to bend with the ureteroscope and enter renal calices and be set close to the stone. Combined with the suction port, OD UAS contributes greatly to dealing with large-burden kidney stones, shortens operation time, and improves single-session SFR.
引用
收藏
页码:1184 / 1190
页数:7
相关论文