A comparative analysis of the influence of refractive error on image acuity using three eye models

被引:1
|
作者
Debowy, Fabian [1 ]
Pierscionek, Barbara [1 ]
机构
[1] Anglia Ruskin Univ, Fac Hlth Educ Med & Social Care, Med Technol Res Ctr, Cambridge, England
基金
欧盟地平线“2020”;
关键词
optical eye models; pupil size; refractive errors; GRADIENT-INDEX; AXIAL LENGTH; OCULAR BIOMETRY; OPTICAL-MODELS; ADAPTIVE MODEL; PUPIL SIZE; HUMAN LENS; MYOPIA; ACCOMMODATION; POPULATION;
D O I
10.1111/opo.13251
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeTo analyse and compare image acuity for different refractive errors generated by either altering axial length or corneal curvature and using three human eye models with two pupil sizes.MethodsThree different eye models, Liou-Brennan, Goncharov and Navarro, were used. Simulations were made (using Ansys Zemax OpticStudio 22.3) for real pupil sizes of 3 and 6 mm with refractive errors ranging from -2 to +2 D in 0.25 D increments. Refractive errors were simulated by varying axial length or corneal curvature. Root mean square (RMS) values were used to determine image acuity.ResultsFor the 3-mm pupil, all models gave similar results, with the Navarro model having slightly higher RMS values for the emmetropic eye. For the 6-mm pupil, the Liou-Brennan and Goncharov eye models gave similar results, with RMS values lower than for the Navarro eye model. The highest RMS value was visible in the axial length-induced refractive errors. Refractive errors generated by altering corneal curvature give smaller RMS values than those generated by altering axial length. The axial length and corneal radius simulations indicate a wide spread of results for myopic, hyperopic and emmetropic eyes. There are multiple outcomes that give the same refractive error, even within a single-eye model. The axial length/corneal curvature ratio showed a higher ratio for myopes than hyperopes for every model.ConclusionsThe influence of refractive error on image acuity varied depending on the simulation method of refractive error and the model used. The origins of refractive error and the influence it has on image acuity need further investigation. As models become more sophisticated, personalised and biologically relevant, they will better represent the image acuity of the eye for varying refractive errors, ethnicities, ages and pupil sizes.
引用
收藏
页码:182 / 190
页数:9
相关论文
共 50 条
  • [31] Spherical equivalent refractive error of the pseudophakic eye with and without prior LASIK predicted using Gaussian optics
    Manns, Fabrice
    Chang, Yu-Cherng
    Cabot, Florence
    Ruggeri, Marco
    Yoo, Sonia H.
    Parel, Jean-Marie A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [32] Correlation between dry eye and refractive error in Saudi young adults using noninvasive Keratograph 4
    Fahmy, Rania M.
    Aldarwesh, Amal
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2018, 66 (05) : 653 - 656
  • [33] Analysis of age, refractive error and gender related changes of the cornea and the anterior segment of the eye with Scheimpflug imaging
    Orucoglu, Faik
    Akman, Mehmet
    Onal, Sumru
    CONTACT LENS & ANTERIOR EYE, 2015, 38 (05): : 345 - 350
  • [34] Comparative analysis of three mathematical models of hydrogen ignition
    Bedarev, IA
    Fedorov, AV
    COMBUSTION EXPLOSION AND SHOCK WAVES, 2006, 42 (01) : 19 - 26
  • [35] Comparative Analysis of Three GARCH Models Based on MCMC
    Gao, Yan
    Zhang, Chengjun
    Zhang, Liyan
    INFORMATION COMPUTING AND APPLICATIONS, PT II, 2011, 244 : 494 - +
  • [36] Comparative MRI analysis of the forebrain of three sauropsida models
    Jimenez, S.
    Santos-Alvarez, I
    Fernandez-Valle, E.
    Castejon, D.
    Villa-Valverde, P.
    Rojo-Salvador, C.
    Perez-Llorens, P.
    Ruiz-Fernandez, M. J.
    Ariza-Pastrana, S.
    Martin-Orti, R.
    Gonzalez-Soriano, Juncal
    Moreno, Nerea
    BRAIN STRUCTURE & FUNCTION, 2024, 229 (06): : 1349 - 1364
  • [37] Comparative Analysis of Three Mathematical Models of Hydrogen Ignition
    I. A. Bedarev
    A. V. Fedorov
    Combustion, Explosion and Shock Waves, 2006, 42 : 19 - 26
  • [38] Consumer Influence Models in Online Buyng: An Eye Tracking Analysis
    Chivu, Raluca-Giorgiana
    Orzan, Gheorghe
    Popa, Ionut-Claudiu
    Petrariu, Radu
    Radu, Andra-Victoria
    VISION 2020: SUSTAINABLE ECONOMIC DEVELOPMENT AND APPLICATION OF INNOVATION MANAGEMENT, 2018, : 7454 - 7459
  • [39] TESTING VISUAL-ACUITY IN THE EMERGENCY DEPARTMENT - A SIMPLE METHOD OF CORRECTING REFRACTIVE ERROR BY USING THE HAND-HELD OPHTHALMOSCOPE
    POWERS, DW
    MEADOR, SA
    ANNALS OF EMERGENCY MEDICINE, 1986, 15 (07) : 818 - 819
  • [40] CLINICAL ANALYSIS OF PSEUDO-PAPILLEDEMA .1. POPULATION, LATERALITY, ACUITY, REFRACTIVE ERROR, OPHTHALMOSCOPIC CHARACTERISTICS, AND COINCIDENT DISEASE
    ROSENBERG, MA
    SAVINO, PJ
    GLASER, JS
    ARCHIVES OF OPHTHALMOLOGY, 1979, 97 (01) : 65 - 70