A comparative analysis of the influence of refractive error on image acuity using three eye models

被引:1
|
作者
Debowy, Fabian [1 ]
Pierscionek, Barbara [1 ]
机构
[1] Anglia Ruskin Univ, Fac Hlth Educ Med & Social Care, Med Technol Res Ctr, Cambridge, England
基金
欧盟地平线“2020”;
关键词
optical eye models; pupil size; refractive errors; GRADIENT-INDEX; AXIAL LENGTH; OCULAR BIOMETRY; OPTICAL-MODELS; ADAPTIVE MODEL; PUPIL SIZE; HUMAN LENS; MYOPIA; ACCOMMODATION; POPULATION;
D O I
10.1111/opo.13251
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeTo analyse and compare image acuity for different refractive errors generated by either altering axial length or corneal curvature and using three human eye models with two pupil sizes.MethodsThree different eye models, Liou-Brennan, Goncharov and Navarro, were used. Simulations were made (using Ansys Zemax OpticStudio 22.3) for real pupil sizes of 3 and 6 mm with refractive errors ranging from -2 to +2 D in 0.25 D increments. Refractive errors were simulated by varying axial length or corneal curvature. Root mean square (RMS) values were used to determine image acuity.ResultsFor the 3-mm pupil, all models gave similar results, with the Navarro model having slightly higher RMS values for the emmetropic eye. For the 6-mm pupil, the Liou-Brennan and Goncharov eye models gave similar results, with RMS values lower than for the Navarro eye model. The highest RMS value was visible in the axial length-induced refractive errors. Refractive errors generated by altering corneal curvature give smaller RMS values than those generated by altering axial length. The axial length and corneal radius simulations indicate a wide spread of results for myopic, hyperopic and emmetropic eyes. There are multiple outcomes that give the same refractive error, even within a single-eye model. The axial length/corneal curvature ratio showed a higher ratio for myopes than hyperopes for every model.ConclusionsThe influence of refractive error on image acuity varied depending on the simulation method of refractive error and the model used. The origins of refractive error and the influence it has on image acuity need further investigation. As models become more sophisticated, personalised and biologically relevant, they will better represent the image acuity of the eye for varying refractive errors, ethnicities, ages and pupil sizes.
引用
收藏
页码:182 / 190
页数:9
相关论文
共 50 条
  • [21] Error analysis on the refractive index measurement through using polarization
    Beijing Inst of Machinery Industry, Beijing, China
    Guangxue Jishu, 4 (48-49, 38):
  • [22] Comparative analysis and classification of features for image models
    Gurevich I.B.
    Koryabkina I.V.
    Pattern Recognition and Image Analysis, 2006, 16 (3) : 265 - 297
  • [23] Comparison of refractive error measurements by three different models of autorefractors and subjective refraction in young adults
    Wosik, Justyna
    Patrzykont, Malgorzata
    Pniewski, Jacek
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2019, 36 (04) : B1 - B6
  • [24] Comparative analysis of three solar models for Tunisia
    Krarti, Moncef
    Seo, Donghyun
    ASHRAE TRANSACTIONS 2006, VOL 112, PT 1, 2006, 112 : 42 - +
  • [25] An analysis of the influence of candidate genes on the refractive error of female DZ twins.
    Prescott, Q
    Hammond, CJ
    Andrew, T
    Dearlove, AM
    Spector, TD
    Bhattacharya, SS
    Webster, AR
    AMERICAN JOURNAL OF HUMAN GENETICS, 2001, 69 (04) : 536 - 536
  • [26] COMPARATIVE ERROR ANALYSIS OF 6 PREDATOR-PREY MODELS
    GARDNER, RH
    ONEILL, RV
    MANKIN, JB
    KUMAR, D
    ECOLOGY, 1980, 61 (02) : 323 - 332
  • [27] Eye detection using eye filter and minimisation of NMF-based reconstruction error in facial image
    Park, C. W.
    Park, K. T.
    Moon, Y. S.
    ELECTRONICS LETTERS, 2010, 46 (02) : 130 - 131
  • [28] Does refractive error influence the association of blood pressure and retinal vessel diameters? The blue mountains eye study
    Wong, TY
    Wang, JJ
    Rochtchina, E
    Klein, R
    Mitchell, P
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2004, 137 (06) : 1050 - 1055
  • [29] Does refractive error influence the association of blood pressure and retinal vessel diameters? The blue mountains eye study
    Tan, A
    Wong, TY
    Wang, JJ
    Rochtchina, E
    Klein, R
    Mitchell, P
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U619 - U619
  • [30] Prediction of the spherical refractive error using machine learning regression models on accommodation data
    Turull-Mallofre, Aina
    Garcia-Guerra, Carlos
    Aldaba, Mikel
    Vilaseca, Meritxell
    Pujol, Jaume
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)