A Fault-Tolerant Control Method for a PMSM Servo Drive System with a Four-Leg Inverter

被引:1
作者
Cui, Peijuan [1 ,2 ,3 ]
Zheng, Zaiping [1 ,2 ,3 ]
Fu, Jie [2 ,3 ]
Zhang, Qianfan [1 ]
An, Linxue [2 ,3 ]
机构
[1] Harbin Inst Technol, Elect Engn & Automat Dept, Harbin 150001, Peoples R China
[2] Beijing Inst Precis Mechatron & Controls, Beijing 100076, Peoples R China
[3] Lab Aerosp Serv Actuat & Transmiss, Beijing 100076, Peoples R China
关键词
fault tolerant; permeant magnet synchronous motor; open phase fault; four leg inverter; STRATEGY;
D O I
10.3390/electronics12183857
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In this paper, a fault tolerant control method is proposed for a permeant magnet synchronous motor (PMSM) servo drive system with four leg inverters to cope with the open phase fault. As one of common faults in the motor drive system, the open phase fault will degrade the control performance and efficiency. Even serious damage is caused in some extreme cases. Hence, it is meaningful to realize the fault tolerance of the drive system with open phase fault. The proposed method includes three parts: a torque-producing current calculator, phase voltage determination and voltage distributor. The torque-producing current calculator is designed by taking the third harmonic flux into consideration to calculate the torque-producing current. In the phase voltage determination, it is proved that the third harmonic flux has no influence on the line voltage equation. For healthy operation and fault operation, the voltage requirements in remaining healthy phases are determined based on the line voltages. Finally, two voltage distributors are designed to distributor the phase voltages into remaining inverter leg. The main difference of two voltage distributors is the polarity of two remaining voltage. Compared to the conventional method, the proposed method can reduce the torque ripple under a postfault condition. In addition, the controller structure will not be changed under a pre-fault and postfault condition. The proposed method has been validated by simulated results and experimental results.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Open-circuit Fault-tolerant Control Strategy of Five-leg Drive in Active Magnetic Bearing
    Ding, Jianfu
    Jiang, Dong
    Hu, Feng
    Yang, Jichang
    Liu, Zicheng
    2022 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2022,
  • [32] Open-Circuit Fault-Tolerant Control Strategy of Five-Leg Drive in Active Magnetic Bearing
    Jiang, Dong
    Ding, Jianfu
    Hu, Feng
    Liu, Zicheng
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2023, 59 (06) : 7545 - 7554
  • [33] Model Predictive Control of Z-Source Four-Leg Inverter for Standalone Photovoltaic System with Unbalanced Load
    Bayhan, Sertac
    Trabelsi, Mohamed
    Abu-Rub, Haitham
    APEC 2016 31ST ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, 2016, : 3663 - 3668
  • [34] Fault-tolerant voltage-fed PWM inverter AC motor drive systems
    Ribeiro, RLD
    Jacobina, CB
    da Silva, ERC
    Lima, AMN
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2004, 51 (02) : 439 - 446
  • [35] Investigation of a Fault-tolerant Three-level T-type Inverter System
    Xu, Shuai
    Zhang, Janzhong
    Hang, Jun
    2015 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2015, : 1632 - 1638
  • [36] Four-switch inverter fed PMSM DTC with SVM approach for fault tolerant operation
    Sun, Dan
    He, Zongyuan
    He, Yikang
    Guan, Yufan
    IEEE IEMDC 2007: PROCEEDINGS OF THE INTERNATIONAL ELECTRIC MACHINES AND DRIVES CONFERENCE, VOLS 1 AND 2, 2007, : 295 - +
  • [37] Investigation of a Fault-Tolerant Three-Level T-Type Inverter System
    Xu, Shuai
    Zhang, Jianzhong
    Hang, Jun
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2017, 53 (05) : 4613 - 4623
  • [38] Independent vector control of Two Induction Motor Drives Fed by a Four-Leg Inverter with compensation method of capacitor voltage
    Tanaka, Haruki
    Saito, Syun
    Matsuse, Kouki
    2012 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING (IAS), 2012,
  • [39] Control Method for Fault-Tolerant Active Power Filters
    Zhang, Chenyu
    Zheng, Jianyong
    Mei, Jun
    Deng, Kai
    Zhou, Fuju
    JOURNAL OF POWER ELECTRONICS, 2015, 15 (03) : 796 - 805
  • [40] A performance analysis of a four-leg inverter in two AC motor drives with independent vector control
    Oka, Kazuo
    Matsuse, Kouki
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2006, 1 (01) : 104 - 107