共 42 条
Investigation of the effects of arch size and implant angulation on the accuracy of digital impression using two intraoral scanners: An in vitro study
被引:1
作者:

Geramipanah, Farideh
论文数: 0 引用数: 0
h-index: 0
机构:
Univ Tehran Med Sci, Fac Dent, Dent Implant Res Ctr, Dept Prosthodont, Tehran, Iran Univ Tehran Med Sci, Fac Dent, Dent Implant Res Ctr, Dept Prosthodont, Tehran, Iran

Sadighpour, Leyla
论文数: 0 引用数: 0
h-index: 0
机构:
Univ Tehran Med Sci, Fac Dent, Dent Implant Res Ctr, Dept Prosthodont, Tehran, Iran Univ Tehran Med Sci, Fac Dent, Dent Implant Res Ctr, Dept Prosthodont, Tehran, Iran

Payaminia, Leila
论文数: 0 引用数: 0
h-index: 0
机构:
Univ Tehran Med Sci, Fac Dent, Dent Implant Res Ctr, Dept Prosthodont, Tehran, Iran Univ Tehran Med Sci, Fac Dent, Dent Implant Res Ctr, Dept Prosthodont, Tehran, Iran
机构:
[1] Univ Tehran Med Sci, Fac Dent, Dent Implant Res Ctr, Dept Prosthodont, Tehran, Iran
来源:
CLINICAL AND EXPERIMENTAL DENTAL RESEARCH
|
2023年
/
9卷
/
06期
关键词:
accuracy;
arch size;
digital impression;
implant;
MARGINAL FIT;
SYSTEM;
RESTORATIONS;
TECHNOLOGY;
PRECISION;
D O I:
10.1002/cre2.793
中图分类号:
R78 [口腔科学];
学科分类号:
1003 ;
摘要:
Objectives: The aim of this in vitro study was to evaluate the effect of arch size and implant angulation on the accuracy of digital impression in two intraoral scanners of Trios (3shape) and CEREC (Omnicam).Material and Methods: Four acrylic models each including six implants at sites 11, 12, 15, 17, 23, and 27 were used, including large with parallel implants, large with angled implants, small with parallel implants, and small with angled implants. After tightening the scan bodies, distance measurements were done using a coordinate measuring machine. Then, each model was scanned 10 times using each scanner. Trueness and precision measurements were finally computed.Results: The trueness values ranged from 20 to 260 mu m in CEREC Omnicam, and from 40 to 1030 mu m in Trios. The precision values ranged from 30 to 190 mu m in CEREC Omnicam, while from 50 to 770 mu m in Trios. The multivariate test analysis indicated that the measured distances via two scanners and different models show different behaviors. Pairwise interactions between these three variables were significant (p < .05). Pairwise interactions between these variables were also significant. (p < .0001).Conclusions: Arch width could affect the accuracy of digital impression; by rotating toward the second quadrant and end points of the scan, errors have increased. However, the angulation of the implants had no effect on the accuracy of digital impression. The CEREC Omnicam scanner showed higher accuracy (trueness and precision) compared to the Trios (3shape) one.
引用
收藏
页码:983 / 992
页数:10
相关论文
共 42 条
- [1] Effects of Implant Angulation, Impression Material, and Variation in Arch Curvature Width on Implant Transfer Model Accuracy[J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (01) : 149 - 157Akalin, Zerrin Fidan论文数: 0 引用数: 0 h-index: 0机构: Univ Marmara, Sch Dent, Dept Prosthet Dent, TR-34360 Istanbul, Turkey Univ Marmara, Sch Dent, Dept Prosthet Dent, TR-34360 Istanbul, TurkeyOzkan, Yasemin Kulak论文数: 0 引用数: 0 h-index: 0机构: Univ Marmara, Fac Dent, Dept Prosthet Dent, TR-34360 Istanbul, Turkey Univ Marmara, Sch Dent, Dept Prosthet Dent, TR-34360 Istanbul, TurkeyEkerim, Ahmet论文数: 0 引用数: 0 h-index: 0机构: Univ Yildiz, Fac Chem & Met Engn, Dept Met & Mat Engn, Istanbul, Turkey Univ Marmara, Sch Dent, Dept Prosthet Dent, TR-34360 Istanbul, Turkey
- [2] Three-Dimensional Accuracy of Digital Impression versus Conventional Method: Effect of Implant Angulation and Connection Type[J]. INTERNATIONAL JOURNAL OF DENTISTRY, 2018, 2018论文数: 引用数: h-index:机构:Siadat, Hakime论文数: 0 引用数: 0 h-index: 0机构: Univ Tehran Med Sci, Dept Prosthodont, Dent Res Inst, Dent Res Ctr, Tehran, Iran Univ Tehran Med Sci, Dept Prosthodont, Dent Res Inst, Dent Res Ctr, Tehran, IranNasirpour, Alireza论文数: 0 引用数: 0 h-index: 0机构: Univ Tehran Med Sci, Sch Dent, Dent Student Res Ctr, Tehran, Iran Univ Tehran Med Sci, Dept Prosthodont, Dent Res Inst, Dent Res Ctr, Tehran, IranHasanzade, Mahya论文数: 0 引用数: 0 h-index: 0机构: Univ Tehran Med Sci, Sch Dent, Dept Prosthodont, Dent Res Ctr,Dent Res Inst, Tehran, Iran Univ Tehran Med Sci, Dept Prosthodont, Dent Res Inst, Dent Res Ctr, Tehran, Iran
- [3] Digital vs. conventional full-arch implant impressions: a comparative study[J]. CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (11) : 1360 - 1367Amin, Sarah论文数: 0 引用数: 0 h-index: 0机构: Tufts Univ, Sch Dent Med, Div Postgrad Prosthodont, 1 Kneeland St, Boston, MA 02111 USA Tufts Univ, Sch Dent Med, Div Postgrad Prosthodont, 1 Kneeland St, Boston, MA 02111 USAWeber, Hans Peter论文数: 0 引用数: 0 h-index: 0机构: Tufts Univ, Sch Dent Med, Div Postgrad Prosthodont, 1 Kneeland St, Boston, MA 02111 USA Tufts Univ, Sch Dent Med, Div Postgrad Prosthodont, 1 Kneeland St, Boston, MA 02111 USAFinkelman, Matthew论文数: 0 引用数: 0 h-index: 0机构: Tufts Univ, Sch Dent Med, Dept Publ Hlth & Community Serv, Boston, MA 02111 USA Tufts Univ, Sch Dent Med, Div Postgrad Prosthodont, 1 Kneeland St, Boston, MA 02111 USAEl Rafie, Khaled论文数: 0 引用数: 0 h-index: 0机构: Tufts Univ, Sch Dent Med, Div Postgrad Prosthodont, 1 Kneeland St, Boston, MA 02111 USA Tufts Univ, Sch Dent Med, Div Postgrad Prosthodont, 1 Kneeland St, Boston, MA 02111 USAKudara, Yukio论文数: 0 引用数: 0 h-index: 0机构: Tufts Univ, Sch Dent Med, Div Postgrad Prosthodont, 1 Kneeland St, Boston, MA 02111 USA Tufts Univ, Sch Dent Med, Div Postgrad Prosthodont, 1 Kneeland St, Boston, MA 02111 USAPapaspyridakos, Panos论文数: 0 引用数: 0 h-index: 0机构: Tufts Univ, Sch Dent Med, Div Postgrad Prosthodont, 1 Kneeland St, Boston, MA 02111 USA Tufts Univ, Sch Dent Med, Div Postgrad Prosthodont, 1 Kneeland St, Boston, MA 02111 USA
- [4] Applicability and accuracy of an intraoral scanner for scanning multiple implants in edentulous mandibles: A pilot study[J]. JOURNAL OF PROSTHETIC DENTISTRY, 2014, 111 (03) : 186 - 194Andriessen, Frank S.论文数: 0 引用数: 0 h-index: 0机构: Acad Ctr Dent Amsterdam, Sect Oral Implantol, NL-1066 EA Amsterdam, Netherlands Acad Ctr Dent Amsterdam, Sect Oral Implantol, NL-1066 EA Amsterdam, NetherlandsRiikens, David R.论文数: 0 引用数: 0 h-index: 0机构: Acad Ctr Dent Amsterdam, Sect Oral Implantol, NL-1066 EA Amsterdam, Netherlands Acad Ctr Dent Amsterdam, Sect Oral Implantol, NL-1066 EA Amsterdam, Netherlandsvan der Meer, Wither J.论文数: 0 引用数: 0 h-index: 0机构: Univ Groningen, Univ Med Ctr Groningen, Dept Orthodont, Groningen, Netherlands Acad Ctr Dent Amsterdam, Sect Oral Implantol, NL-1066 EA Amsterdam, NetherlandsWismeijer, Daniell W.论文数: 0 引用数: 0 h-index: 0机构: Acad Ctr Dent Amsterdam, Dept Oral Funct & Restorat Dent, NL-1066 EA Amsterdam, Netherlands Acad Ctr Dent Amsterdam, Sect Oral Implantol & Prosthodont, NL-1066 EA Amsterdam, Netherlands Acad Ctr Dent Amsterdam, Sect Oral Implantol, NL-1066 EA Amsterdam, Netherlands
- [5] Accuracy of Digital vs Conventional Implant Impression Approach: A Three-Dimensional Comparative In Vitro Analysis[J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (04) : 792 - 799Basaki, Kinga论文数: 0 引用数: 0 h-index: 0机构: McGill Univ, Fac Dent, Prosthodont & Restorat Dent, Montreal, PQ, Canada McGill Univ, Fac Dent, Prosthodont & Restorat Dent, Montreal, PQ, Canada论文数: 引用数: h-index:机构:De Souza, Grace论文数: 0 引用数: 0 h-index: 0机构: Univ Toronto, Fac Dent, Restorat Dent, Toronto, ON, Canada McGill Univ, Fac Dent, Prosthodont & Restorat Dent, Montreal, PQ, CanadaFiner, Yoav论文数: 0 引用数: 0 h-index: 0机构: Univ Toronto, Fac Dent, Prosthodont, Toronto, ON, Canada McGill Univ, Fac Dent, Prosthodont & Restorat Dent, Montreal, PQ, Canada
- [6] Accuracy of single-tooth restorations based on intraoral digital and conventional impressions in patients[J]. CLINICAL ORAL INVESTIGATIONS, 2015, 19 (08) : 2027 - 2034Boeddinghaus, Moritz论文数: 0 引用数: 0 h-index: 0机构: Univ Giessen, Dept Prosthodont, D-35390 Giessen, Germany Univ Giessen, Dept Prosthodont, D-35390 Giessen, GermanyBreloer, Eva Sabina论文数: 0 引用数: 0 h-index: 0机构: Univ Giessen, Dept Prosthodont, D-35390 Giessen, Germany Univ Giessen, Dept Prosthodont, D-35390 Giessen, GermanyRehmann, Peter论文数: 0 引用数: 0 h-index: 0机构: Univ Giessen, Dept Prosthodont, D-35390 Giessen, Germany Univ Giessen, Dept Prosthodont, D-35390 Giessen, GermanyWoestmann, Bernd论文数: 0 引用数: 0 h-index: 0机构: Univ Giessen, Dept Prosthodont, D-35390 Giessen, Germany Univ Giessen, Dept Prosthodont, D-35390 Giessen, Germany
- [7] In Vitro Three-Dimensional Accuracy of Digital Implant Impressions: The Effect of Implant Angulation[J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (02) : 313 - 321Chia, Vanessa A.论文数: 0 引用数: 0 h-index: 0机构: Natl Dent Ctr Singapore, Dept Restorat Dent, Singapore, Singapore Natl Dent Ctr Singapore, Dept Restorat Dent, Singapore, SingaporeEsguerra, Roxanna J.论文数: 0 引用数: 0 h-index: 0机构: Natl Univ Singapore, Fac Dent, 11 Lower Kent Ridge Rd, Singapore 119083, Singapore Natl Dent Ctr Singapore, Dept Restorat Dent, Singapore, SingaporeTeoh, Khim Hean论文数: 0 引用数: 0 h-index: 0机构: Natl Dent Ctr Singapore, Dept Restorat Dent, Singapore, Singapore Natl Dent Ctr Singapore, Dept Restorat Dent, Singapore, SingaporeTeo, Juin Wei论文数: 0 引用数: 0 h-index: 0机构: Khoo Teck Puat Hosp, Dept Dent, Singapore, Singapore Natl Dent Ctr Singapore, Dept Restorat Dent, Singapore, SingaporeWong, Keng Mun论文数: 0 引用数: 0 h-index: 0机构: Natl Univ Singapore, Fac Dent, 11 Lower Kent Ridge Rd, Singapore 119083, Singapore Natl Dent Ctr Singapore, Dept Restorat Dent, Singapore, SingaporeTan, Keson B.论文数: 0 引用数: 0 h-index: 0机构: Natl Univ Singapore, Fac Dent, 11 Lower Kent Ridge Rd, Singapore 119083, Singapore Natl Dent Ctr Singapore, Dept Restorat Dent, Singapore, Singapore
- [8] Impressions are changing Deciding on conventional, digital or digital plus in-office milling[J]. JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2009, 140 (10) : 1301 - 1304Christensen, Gordon J.论文数: 0 引用数: 0 h-index: 0机构: CR Fdn, Provo, UT 84604 USA Scottsdale Ctr Dent, Scottsdale, AZ USA Brigham Young Univ, Provo, UT 84602 USA Univ Utah, Salt Lake City, UT USA CR Fdn, Provo, UT 84604 USA
- [9] In vitro assessment of the accuracy of digital impressions prepared using a single system for full-arch restorations on implants[J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2018, 13 (07) : 1097 - 1108Ciocca, Leonardo论文数: 0 引用数: 0 h-index: 0机构: Alma Mater Studiorum Univ Bologna, Sect Prosthodont, Dept Biomed & Neuromotor Sci, Via S Vitale 59, I-40125 Bologna, Italy Alma Mater Studiorum Univ Bologna, Sect Prosthodont, Dept Biomed & Neuromotor Sci, Via S Vitale 59, I-40125 Bologna, ItalyMeneghello, Roberto论文数: 0 引用数: 0 h-index: 0机构: Univ Padua, Dept Management & Engn, Stradella San Nicola 3, I-36100 Vicenza, Italy Alma Mater Studiorum Univ Bologna, Sect Prosthodont, Dept Biomed & Neuromotor Sci, Via S Vitale 59, I-40125 Bologna, ItalyMonaco, Carlo论文数: 0 引用数: 0 h-index: 0机构: Alma Mater Studiorum Univ Bologna, Sect Prosthodont, Dept Biomed & Neuromotor Sci, Via S Vitale 59, I-40125 Bologna, Italy Alma Mater Studiorum Univ Bologna, Sect Prosthodont, Dept Biomed & Neuromotor Sci, Via S Vitale 59, I-40125 Bologna, ItalySavio, Gianpaolo论文数: 0 引用数: 0 h-index: 0机构: Univ Padua, Dept Civil Environm & Architectural Engn, Via Venezia 1, I-35131 Padua, Italy Alma Mater Studiorum Univ Bologna, Sect Prosthodont, Dept Biomed & Neuromotor Sci, Via S Vitale 59, I-40125 Bologna, ItalyScheda, Lorenzo论文数: 0 引用数: 0 h-index: 0机构: Alma Mater Studiorum Univ Bologna, Sect Prosthodont, Dept Biomed & Neuromotor Sci, Via S Vitale 59, I-40125 Bologna, ItalyGatto, Maria Rosaria论文数: 0 引用数: 0 h-index: 0机构: Alma Mater Studiorum Univ Bologna, Dept Biomed & Neuromotor Sci, Via S Vitale 59, I-40125 Bologna, Italy Alma Mater Studiorum Univ Bologna, Sect Prosthodont, Dept Biomed & Neuromotor Sci, Via S Vitale 59, I-40125 Bologna, ItalyBaldissara, Paolo论文数: 0 引用数: 0 h-index: 0机构: Alma Mater Studiorum Univ Bologna, Sect Prosthodont, Dept Biomed & Neuromotor Sci, Via S Vitale 59, I-40125 Bologna, Italy Alma Mater Studiorum Univ Bologna, Sect Prosthodont, Dept Biomed & Neuromotor Sci, Via S Vitale 59, I-40125 Bologna, Italy
- [10] Intrasubject comparison of digital vs. conventional workflow for screw-retained single-implant crowns: Prosthodontic and patient-centered outcomes[J]. CLINICAL ORAL IMPLANTS RESEARCH, 2019, 30 (09) : 892 - 902Delize, Vincent论文数: 0 引用数: 0 h-index: 0机构: Univ Liege, Fac Med, Dept Removable Prosthodont, Liege, Belgium Univ Liege, Fac Med, Dept Removable Prosthodont, Liege, BelgiumBouhy, Alice论文数: 0 引用数: 0 h-index: 0机构: Univ Liege, Fac Med, Dept Removable Prosthodont, Liege, Belgium Univ Liege, Fac Med, Dept Removable Prosthodont, Liege, BelgiumLambert, France论文数: 0 引用数: 0 h-index: 0机构: Univ Liege, Fac Med, Dept Periodontol & Oral Surg, CHU Liege,Dent Biomat Res Unit, Liege, Belgium Univ Liege, Fac Med, Dept Removable Prosthodont, Liege, BelgiumLamy, Marc论文数: 0 引用数: 0 h-index: 0机构: Univ Liege, Fac Med, Dept Removable Prosthodont, Liege, Belgium Univ Liege, Fac Med, Dept Removable Prosthodont, Liege, Belgium