Physiological and degenerative loading of bovine intervertebral disc in a bioreactor: A finite element study of complex motions

被引:3
作者
Ristaniemi, Aapo [1 ]
Secerovic, Amra [1 ]
Dischl, Vincent [2 ]
Crivelli, Francesco [3 ]
Heub, Sarah [4 ]
Ledroit, Diane [4 ]
Weder, Gilles [4 ]
Grad, Sibylle [1 ,2 ]
Ferguson, Stephen J.
机构
[1] AO Res Inst Davos, Clavadelerstr 8, CH-7270 Davos, Switzerland
[2] Swiss Fed Inst Technol, Inst Biomech, Zurich, Switzerland
[3] Swiss Ctr Elect & Microtechnol, CSEM, Alpnach, Switzerland
[4] Swiss Ctr Elect & Microtechnol, CSEM, Neuchatel, Switzerland
基金
瑞士国家科学基金会;
关键词
Intervertebral disc; Degeneration; Bovine; Finite element model; ANNULUS FIBROSUS; ORGAN-CULTURE; COMPRESSION; MECHANICS; MODEL; TORSION; STRAIN; SPINE;
D O I
10.1016/j.jmbbm.2023.105900
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Intervertebral disc (IVD) degeneration and regenerative therapies are commonly studied in organ-culture ex-periments with uniaxial compressive loading. Recently, in our laboratory, we established a bioreactor system capable of applying loads in six degrees-of-freedom (DOF) to bovine IVDs, which replicates more closely the complex multi-axial loading of the IVD in vivo. However, the magnitudes of loading that are physiological (able to maintain cell viability) or mechanically degenerative are unknown for load cases combining several DOFs. This study aimed to establish physiological and degenerative levels of maximum principal strains and stresses in the bovine IVD tissue and to investigate how they are achieved under complex load cases related to common daily activities.The physiological and degenerative levels of maximum principal strains and stresses were determined via finite element (FE) analysis of bovine IVD subjected to experimentally established physiological and degenera-tive compressive loading protocols. Then, complex load cases, such as a combination of compression + flexion + torsion, were applied on the FE-model with increasing magnitudes of loading to discover when physiological and degenerative tissue strains and stresses were reached.When applying 0.1 MPa of compression and +/- 2-3 degrees of flexion and +/- 1-2 degrees of torsion the investigated me-chanical parameters remained at physiological levels, but with +/- 6-8 degrees of flexion in combination with +/- 2-4 degrees of torsion, the stresses in the outer annulus fibrosus (OAF) exceeded degenerative levels.In the case of compression + flexion + torsion, the mechanical degeneration likely initiates at the OAF when loading magnitudes are high enough. The physiological and degenerative magnitudes can be used as guidelines for bioreactor experiments with bovine IVDs.
引用
收藏
页数:9
相关论文
共 50 条
[21]   Finite element study of nutrient diffusion in the human intervertebral disc [J].
Sélard, É ;
Shirazi-Adl, A ;
Urban, JPG .
SPINE, 2003, 28 (17) :1945-1953
[22]   Biomechanical response of lumbar intervertebral disc in daily sitting postures: a poroelastic finite element analysis [J].
Zheng, Liang-dong ;
Cao, Yu-ting ;
Yang, Yi-ting ;
Xu, Meng-lei ;
Zeng, Hui-zi ;
Zhu, Shi-jie ;
Candito, Antonio ;
Chen, Yuhang ;
Zhu, Rui ;
Cheng, Li-ming .
COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2023, 26 (16) :1941-1950
[23]   Validation and application of an intervertebral disc finite element model utilizing independently constructed tissue-level constitutive formulations that are nonlinear, anisotropic, and time-dependent [J].
Jacobs, Nathan T. ;
Cortes, Daniel H. ;
Peloquin, John M. ;
Vresilovic, Edward J. ;
Elliott, Dawn M. .
JOURNAL OF BIOMECHANICS, 2014, 47 (11) :2540-2546
[24]   Osmoviscoelastic finite element model of the intervertebral disc [J].
Yvonne Schroeder ;
Wouter Wilson ;
Jacques M. Huyghe ;
Frank P. T. Baaijens .
European Spine Journal, 2006, 15 :361-371
[25]   Finite element investigation of the intervertebral disc behaviour [J].
Aour, B. ;
Damba, N. .
COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2014, 17 :58-59
[26]   Osmoviscoelastic finite element model of the intervertebral disc [J].
Schroeder, Yvonne ;
Wilson, Wouter ;
Huyghe, Jacques M. ;
Baaijens, Frank P. T. .
EUROPEAN SPINE JOURNAL, 2006, 15 (Suppl 3) :S361-S371
[27]   Impact response of the intervertebral disc in a finite-element model [J].
Lee, CK ;
Kim, EY ;
Lee, CS ;
Hong, YM ;
Jung, JM ;
Goel, VK .
SPINE, 2000, 25 (19) :2431-2439
[28]   Numerical implementation of an osmo-poro-visco-hyperelastic finite element solver: application to the intervertebral disc [J].
Castro, A. P. G. ;
Alves, J. L. .
COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2021, 24 (05) :538-550
[29]   Region Specific Response of Intervertebral Disc Cells to Complex Dynamic Loading: An Organ Culture Study Using a Dynamic Torsion-Compression Bioreactor [J].
Chan, Samantha C. W. ;
Walser, Jochen ;
Kaeppeli, Patrick ;
Shamsollahi, Mohammad Javad ;
Ferguson, Stephen J. ;
Gantenbein-Ritter, Benjamin .
PLOS ONE, 2013, 8 (08)
[30]   Effects of Tobacco Smoking on the Degeneration of the Intervertebral Disc: A Finite Element Study [J].
Elmasry, Shady ;
Asfour, Shihab ;
Vaccari, Juan Pablo de Rivero ;
Travascio, Francesco .
PLOS ONE, 2015, 10 (08)