Hemodynamic Precision in the Neonatal Intensive Care Unit using Targeted Neonatal Echocardiography

被引:2
作者
Makoni, Marjorie [1 ]
Chatmethakul, Trassanee [1 ,2 ]
Giesinger, Regan [2 ]
McNamara, Patrick J. [2 ]
机构
[1] Univ Oklahoma Hlth Sci Ctr, Dept Pediat, Div Neonatal Perinatal Med, Oklahoma City, OK 73104 USA
[2] Univ Iowa, Dept Pediat, Div Neonatol, Iowa City, IA USA
来源
JOVE-JOURNAL OF VISUALIZED EXPERIMENTS | 2023年 / 191期
基金
美国国家卫生研究院;
关键词
VENTRICULAR DIASTOLIC FUNCTION; REFERENCE VALUES; PULMONARY-HYPERTENSION; PRETERM INFANTS; CARDIAC-OUTPUT; DIMENSIONS; CHILDREN; FLOW; MANAGEMENT; DIAGNOSIS;
D O I
10.3791/64257
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Targeted neonatal echocardiography (TnECHO) refers to the use of comprehensive echocardiographic evaluation and physiologic data to obtain accurate, reliable, and real-time information on developmental hemodynamics in sick newborns. The comprehensive assessment is based on a multiparametric approach that overcomes the reliability issues of individual measurements, allows for earlier recognition of cardiovascular compromise and promotes enhanced diagnostic precision and timely management. TnECHO-driven research has led to an enhanced understanding of the mechanisms of illness and the development of predictive models to identify at-risk populations. This information may then be used to formulate a diagnostic impression and provide individualized guidance for the selection of cardiovascular therapies. TnECHO is based on the expert consultative model in which a neonatologist, with advanced training in neonatal hemodynamics, performs comprehensive and standardized TnECHO assessments. The distinction from point of care ultrasonography (POCUS), which provides limited and brief one-time assessments, is important. Neonatal hemodynamics training is a 1-year structured program designed to optimize image acquisition, measurement analysis, and hemodynamic knowledge (physiology, pharmacotherapy) to support cardiovascular decision-making. Neonatologists with hemodynamic expertise are trained to recognize deviations from normal anatomy and appropriately refer cases of possible structural abnormalities. We provide an outline of neonatal hemodynamics training, the standardized TnECHO imaging protocol, and an example of representative echo findings in a hemodynamically significant patent ductus arteriosus.
引用
收藏
页数:19
相关论文
共 51 条
[21]   A Comprehensive Echocardiographic Protocol for Assessing Neonatal Right Ventricular Dimensions and Function in the Transitional Period: Normative Data and Z Scores [J].
Jain, Amish ;
Mohamed, Adel ;
El-Khuffash, Afif ;
Connelly, Kim A. ;
Dallaire, Frederic ;
Jankov, Robert P. ;
McNamara, Patrick J. ;
Mertens, Luc .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2014, 27 (12) :1293-1304
[22]   Normal values of M mode echocardiographic measurements of more than 2000 healthy infants and children in central Europe [J].
Kampmann, C ;
Wiethoff, CM ;
Wenzel, A ;
Stolz, G ;
Betancor, M ;
Wippermann, CF ;
Huth, RG ;
Habermehl, P ;
Knuf, M ;
Emschermann, T ;
Stopfkuchen, H .
HEART, 2000, 83 (06) :667-672
[23]  
Koestenberger M., J AM SOC ECHOCARDIOG
[24]   Systolic Right Ventricular Function in Preterm and Term Neonates: Reference Values of the Tricuspid Annular Plane Systolic Excursion (TAPSE) in 258 Patients and Calculation of Z-Score Values [J].
Koestenberger, Martin ;
Nagel, Bert ;
Ravekes, William ;
Urlesberger, Berndt ;
Raith, Wolfgang ;
Avian, Alexander ;
Halb, Verena ;
Cvirn, Gerhard ;
Fritsch, Peter ;
Gamillscheg, Andreas .
NEONATOLOGY, 2011, 100 (01) :85-92
[25]   Evaluation and Management of Pulmonary Hypertension in Children with Bronchopulmonary Dysplasia [J].
Krishnan, Usha ;
Feinstein, Jeffrey A. ;
Adatia, Ian ;
Austin, Eric D. ;
Mullen, Mary P. ;
Hopper, Rachel K. ;
Hanna, Brian ;
Romer, Lew ;
Keller, Roberta L. ;
Fineman, Jeffrey ;
Steinhorn, Robin ;
Kinsella, John P. ;
Ivy, D. Dunbar ;
Rosenzweig, Erika Berman ;
Raj, Usha ;
Humpl, Tilman ;
Abman, Steven H. .
JOURNAL OF PEDIATRICS, 2017, 188 :24-+
[26]   The Reproducibility and Absolute Values of Echocardiographic Measurements of Left Ventricular Size and Function in Children Are Algorithm Dependent [J].
Margossian, Renee ;
Chen, Shan ;
Sleeper, Lynn A. ;
Tani, Lloyd Y. ;
Shirali, Girish ;
Golding, Fraser ;
Tierney, Elif Seda Selamet ;
Altmann, Karen ;
Campbell, Michael J. ;
Szwast, Anita ;
Sharkey, Angela ;
Radojewski, Elizabeth ;
Colan, Steven D. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2015, 28 (05) :549-U137
[27]   CONTINUOUS-WAVE DOPPLER ECHOCARDIOGRAPHIC DETECTION OF PULMONARY REGURGITATION AND ITS APPLICATION TO NONINVASIVE ESTIMATION OF PULMONARY-ARTERY PRESSURE [J].
MASUYAMA, T ;
KODAMA, K ;
KITABATAKE, A ;
SATO, H ;
NANTO, S ;
INOUE, M .
CIRCULATION, 1986, 74 (03) :484-492
[28]   Growth of Neonatal Hemodynamics Programs and Targeted Neonatal Echocardiography Performed by Neonatologists [J].
McNamara, Patrick ;
Lai, Wyman .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2020, 33 (10) :15A-16A
[29]  
Mertens L., J Am Soc Echocardiogr
[30]  
Mertens L., J PAEDIAT CHILD HLTH, V1