Biomechanical design optimization of distal femur locked plates: A review

被引:6
|
作者
Zdero, Radovan [1 ]
Gide, Kunal [2 ]
Brzozowski, Pawel [1 ]
Schemitsch, Emil H. [1 ,3 ]
Bagheri, Z. Shaghayegh [2 ,4 ]
机构
[1] Victoria Hosp, Orthopaed Biomech Lab, London, ON, Canada
[2] George Mason Univ, Dept Mech Engn, Nguyan Engn Bldg,4400 Univ Dr, Fairfax, VA 22030 USA
[3] Western Univ, Div Orthopaed Surg, London, ON, Canada
[4] Univ Hlth Network, Kite Res Inst, Toronto Rehab Inst, Toronto, ON, Canada
关键词
Biomechanics; optimization; distal femur; locked plates; review; INVASIVE STABILIZATION SYSTEM; LOCKING COMPRESSION PLATE; FINITE-ELEMENT-ANALYSIS; ANGLED BLADE PLATE; INTERNAL-FIXATION; CONSTRUCT STIFFNESS; STAINLESS-STEEL; WORKING LENGTH; INTERFRAGMENTARY MOVEMENT; INTRAMEDULLARY NAIL;
D O I
10.1177/09544119231181487
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Clinical findings, manufacturer instructions, and surgeon's preferences often dictate the implantation of distal femur locked plates (DFLPs), but healing problems and implant failures still persist. Also, most biomechanical researchers compare a particular DFLP configuration to implants like plates and nails. However, this begs the question: Is this specific DFLP configuration biomechanically optimal to encourage early callus formation, reduce bone and implant failure, and minimize bone "stress shielding''? Consequently, it is crucial to optimize, or characterize, the biomechanical performance (stiffness, strength, fracture micro-motion, bone stress, plate stress) of DFLPs influenced by plate variables (geometry, position, material) and screw variables (distribution, size, number, angle, material). Thus, this article reviews 20 years of biomechanical design optimization studies on DFLPs. As such, Google Scholar and PubMed websites were searched for articles in English published since 2000 using the terms "distal femur plates'' or "supracondylar femur plates'' plus "biomechanics/biomechanical'' and "locked/locking,'' followed by searching article reference lists. Key numerical outcomes and common trends were identified, such as: (a) plate cross-sectional area moment of inertia can be enlarged to lower plate stress at the fracture; (b) plate material has a larger influence on plate stress than plate thickness, buttress screws, and inserts for empty plate holes; (c) screw distribution has a major influence on fracture micro-motion, etc. Recommendations for future work and clinical implications are then provided, such as: (a) simultaneously optimizing fracture micro-motion for early healing, reducing bone and implant stresses to prevent re-injury, lowering "stress shielding'' to avoid bone resorption, and ensuring adequate fatigue life; (b) examining alternate non-metallic materials for plates and screws; (c) assessing the influence of condylar screw number, distribution, and angulation, etc. This information can benefit biomedical engineers in designing or evaluating DFLPs, as well as orthopedic surgeons in choosing the best DFLPs for their patients.
引用
收藏
页码:791 / 805
页数:15
相关论文
共 50 条
  • [1] Biomechanical design optimization of proximal humerus locked plates: A review
    Zdero, Radovan
    Brzozowski, Pawel
    Schemitsch, Emil H.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2024, 55 (02):
  • [2] Biomechanical Design Optimization of Distal Humerus Fracture Plates: A Review
    Zdero, Radovan
    Brzozowski, Pawel
    Schemitsch, Emil H.
    BIOMED RESEARCH INTERNATIONAL, 2024, 2024
  • [3] Supplementation of Lateral Locked Plating for Distal Femur Fractures: A Biomechanical Study
    Fontenot, Philip B.
    Diaz, Miguel
    Stoops, Kyle
    Barrick, Brett
    Santoni, Brandon
    Mir, Hassan
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2019, 33 (12) : 642 - 648
  • [4] Biomechanical Design Optimization of Clavicle Midshaft Fracture Plates: A Review
    Zdero, Radovan
    Brzozowski, Pawel
    Schemitsch, Emil H.
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2024, 44 (03) : 307 - 316
  • [5] Biomechanical Characterization of an Osteoporotic Artificial Bone Model for the Distal Femur
    Waehnert, Dirk
    Hoffmeier, Konrad L.
    Klos, Kajetan
    Stolarczyk, Yves
    Froeber, Rosemarie
    Hofmann, Gunther O.
    Mueckley, Thomas
    JOURNAL OF BIOMATERIALS APPLICATIONS, 2012, 26 (05) : 565 - 579
  • [6] Distal femur fractures of the elderly-Different treatment options in a biomechanical comparison
    Waehnert, Dirk
    Hoffmeier, Konrad
    Froeber, Rosemarie
    Hofmann, Gunther O.
    Mueckley, Thomas
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2011, 42 (07): : 655 - 659
  • [7] Dynamization of locked plating on distal femur fracture
    Oh, Jong-Keon
    Hwang, Jin-Ho
    Lee, Seoung-Joon
    Kim, Jin-Il
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2011, 131 (04) : 535 - 539
  • [8] Distal femur fractures. Surgical techniques and a review of the literature
    Ehlinger, M.
    Ducrot, G.
    Adam, P.
    Bonnomet, F.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2013, 99 (03) : 353 - 360
  • [9] Pitfalls in the Application of Distal Femur Plates for Fractures
    Collinge, Cory A.
    Gardner, Michael J.
    Crist, Brett D.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 (11) : 695 - 706
  • [10] Mono- versus polyaxial locking plates in distal femur fractures - a biomechanical comparison of the Non-Contact-Bridging- (NCB) and the PERILOC-plate
    El-Zayat, Bilal Farouk
    Efe, Turgay
    Ruchholtz, Steffen
    Khatib, Salim
    Timmesfeld, Nina
    Krueger, Antonio
    Zettl, Ralph
    BMC MUSCULOSKELETAL DISORDERS, 2014, 15