Loop-mediated isothermal amplification combined with lateral flow biosensor for rapid and sensitive detection of monkeypox virus

被引:11
|
作者
Huang, Xiaolan [1 ]
Xiao, Fei [1 ]
Jia, Nan [1 ]
Sun, Chunrong [1 ]
Fu, Jin [1 ]
Xu, Zheng [1 ]
Cui, Xiaodai [1 ]
Huang, Hui [2 ]
Qu, Dong [3 ]
Zhou, Juan [1 ]
Wang, Yi [1 ]
机构
[1] Capital Inst Pediat, Expt Res Ctr, Beijing, Peoples R China
[2] Affiliated Capital Inst Pediat, Dept Infect Dis, Childrens Hosp, Beijing, Peoples R China
[3] Affiliated Capital Inst Pediat, Dept Crit Med, Childrens Hosp, Beijing, Peoples R China
关键词
monkeypox virus; loop-mediated isothermal amplification; lateral flow biosensor; nanoparticles; diagnosis; INFECTION; CONGO;
D O I
10.3389/fpubh.2023.1132896
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
The ongoing outbreak of the monkeypox, caused by monkeypox virus (MPXV), has been a public health emergency of international concern, indicating an urgent need for rapid and sensitive MPXV detection. Here, we designed a diagnostic test based on loop-mediated isothermal amplification (LAMP) and nanoparticle-based lateral flow biosensor(LFB)for diagnosis of MPXV infection, termed MPX-LAMP-LFB. A set of six LAMP primers was designed based the ATI gene of MPXV, and LAMP amplification of MPXV templates was performed at 63 degrees C for only 40 min. The results were rapidly and visually decided using the LFB test within 2 min. The MPX-LAMP-LFB assay can specifically detect MPXV strains without cross-reaction with non-MPXV pathogens. The sensitivity of the MPX-LAMP-LFB assay is as low as 5 copies/mu l of plasmid template and 12.5 copies/mu l of pseudovirus in human blood samples. The whole process of the MPX-LAMP-LFB assay could be completed similar to 1 h, including rapid template preparation (15 min), LAMP reaction (40 min)and result reporting (< 2 min). Collectively, MPX-LAMP-LFB assay developed here is a useful tool for rapid and reliable diagnosis of MPXV infection.
引用
收藏
页数:9
相关论文
共 50 条
  • [11] Rapid and sensitive detection of infectious hypodermal and hematopoietic necrosis virus by loop-mediated isothermal amplification combined with a lateral flow dipstick
    Arunrut, Narong
    Prombun, Photchanathorn
    Saksmerprome, Vanvimon
    Flegel, Timothy W.
    Kiatpathomchai, Wansika
    JOURNAL OF VIROLOGICAL METHODS, 2011, 171 (01) : 21 - 25
  • [12] Rapid and sensitive detection of infectious spleen and kidney necrosis virus by loop-mediated isothermal amplification combined with a lateral flow dipstick
    Ding, W. C.
    Chen, Jiong
    Shi, Y. H.
    Lu, X. J.
    Li, M. Y.
    ARCHIVES OF VIROLOGY, 2010, 155 (03) : 385 - 389
  • [13] Application of loop-mediated isothermal amplification combined with lateral flow dipstick to rapid and sensitive detection of Alexandrium catenella
    Liang Wang
    Guofu Chen
    Chunyun Zhang
    Yuanyuan Wang
    Rui Sun
    Environmental Science and Pollution Research, 2020, 27 : 4246 - 4257
  • [14] Sensitive and rapid detection of Prymnesium parvum (Haptophyceae) by loop-mediated isothermal amplification combined with a lateral flow dipstick
    Zhu, Peng
    Huang, Hai-Long
    Zhou, Cheng-Xu
    Xu, Jilin
    Qiao, Long-Liang
    Dang, Chen-Yang
    Pang, Jian-Hu
    Gao, Wei-Fang
    Yan, Xiao-Jun
    AQUACULTURE, 2019, 505 : 199 - 205
  • [15] Rapid and Sensitive Detection of Salmonella in Chickens Using Loop-Mediated Isothermal Amplification Combined with a Lateral Flow Dipstick
    Liu, Zhi-Ke
    Zhang, Qiu-Yu
    Yang, Ning-Ning
    Xu, Ming-Guo
    Xu, Jin-Feng
    Jing, Ming-Long
    Wu, Wen-Xing
    Lu, Ya-Dong
    Shi, Feng
    Chen, Chuang-Fu
    JOURNAL OF MICROBIOLOGY AND BIOTECHNOLOGY, 2019, 29 (03) : 454 - 464
  • [16] Application of loop-mediated isothermal amplification combined with lateral flow dipstick to rapid and sensitive detection of Alexandrium catenella
    Wang, Liang
    Chen, Guofu
    Zhang, Chunyun
    Wang, Yuanyuan
    Sun, Rui
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2020, 27 (04) : 4246 - 4257
  • [17] Sensitive and rapid detection of Zika virus by loop-mediated isothermal amplification
    Zhao, Jiangtao
    Feng, Ruo
    VIRUS GENES, 2019, 55 (01) : 43 - 50
  • [18] Sensitive and rapid detection of Zika virus by loop-mediated isothermal amplification
    Jiangtao Zhao
    Ruo Feng
    Virus Genes, 2019, 55 : 43 - 50
  • [19] Development of a Loop-Mediated Isothermal Amplification Method for Rapid and Visual Detection of Monkeypox Virus
    Feng, Junxia
    Xue, Guanhua
    Cui, Xiaohu
    Du, Bing
    Feng, Yanling
    Cui, Jinghua
    Zhao, Hanqing
    Gan, Lin
    Fan, Zheng
    Fu, Tongtong
    Xu, Ziying
    Du, Shuheng
    Zhou, Yao
    Zhang, Rui
    Fu, Hanyu
    Tian, Ziyan
    Zhang, Qun
    Yan, Chao
    Yuan, Jing
    MICROBIOLOGY SPECTRUM, 2022, 10 (05):
  • [20] Rapid and sensitive detection of infectious bursal disease virus by reverse transcription loop-mediated isothermal amplification combined with a lateral flow dipstick
    Tsai, Su-Ming
    Liu, Hung-Jen
    Shien, Jui-Hung
    Lee, Long-Huw
    Chang, Po-Chung
    Wang, Chi-Young
    JOURNAL OF VIROLOGICAL METHODS, 2012, 181 (01) : 117 - 124