A nonparametric measure of noise in x-ray diagnostic images-mammography

被引:1
|
作者
Anton, M. [1 ]
Maeder, U. [2 ]
Schopphoven, S. [3 ]
Reginatto, M. [1 ]
机构
[1] Phys Tech Bundesanstalt Braunschweig & Berlin, Berlin, Germany
[2] Univ Appl Sci, Inst Med Phys & Radiat Protect, Giessen, Germany
[3] Reference Ctr Mammog Screening Southwest Germany, Giessen, Germany
关键词
quality assurance; mammography; noise measure; non-maximum suppression; nonparametric; PATIENT-SPECIFIC QUANTIFICATION; NO-REFERENCE; QUALITY ASSESSMENT; OBSERVER PERFORMANCE; AUTOMATED TECHNIQUE; PARAMETER;
D O I
10.1088/1361-6560/acb485
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. In x-ray diagnostics, modern image reconstruction or image processing methods may render established methods of image quality assessment inadequate. Task specific quality assessment by using model observers has the disadvantage of being very labour-intensive. Therefore, it appears highly desirable to develop novel image quality parameters that neither rely on the linearity and the shift-invariace of the imaging system nor require the acquisition of hundreds of images as is necessary for the application of model observers, and which can be derived directly from diagnostic images. Approach. A new measure for the noise based on non-maximum-suppression images is defined and its properties are explored using simulated images before it is applied to an exposure series of mammograms of a homogeneous phantom and a 3D-printed breast phantom to demonstrate its usefulness under realistic conditions. Main results. The new noise parameter cannot only be derived from images with a homogeneous background but it can be extracted directly from images containing anatomic structures and is proportional to the standard deviation of the noise. At present, the applicability is restricted to mammography, which satisfies the assumption of short covariance length of the noise. Significance. The new measure of the noise is but a first step of the development of a set of parameters that are required to quantify image quality directly from diagnostic images without relying on the assumption of a linear, shift-invariant system, e.g. by providing measures of sharpness, contrast and structural complexity, in addition to the noise measure. For mammography, a convenient method is now available to quantify noise in processed diagnostic images.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Establishing national diagnostic reference levels in radiography, mammography, and dual-energy x-ray absorptiometry services in Ireland and comparing these with European diagnostic reference levels
    O'Hora, Lee
    Neville, Noelle
    Tuffy, John
    Craig, Agnella
    O'Brien, Kirsten
    Sugrue, Kay
    McGarry, Maeve
    Duggan, Brendan
    Egan, Sean
    EUROPEAN RADIOLOGY, 2023, 33 (12) : 9469 - 9478
  • [42] Establishing national diagnostic reference levels in radiography, mammography, and dual-energy x-ray absorptiometry services in Ireland and comparing these with European diagnostic reference levels
    Lee O’Hora
    Noelle Neville
    John Tuffy
    Agnella Craig
    Kirsten O’Brien
    Kay Sugrue
    Maeve McGarry
    Brendan Duggan
    Sean Egan
    European Radiology, 2023, 33 : 9469 - 9478
  • [43] Memory Effects in Subjective Quality Assessment of X-Ray Images
    Landre, Victor
    Pedersen, Marius
    Waaler, Dag
    IMAGE ANALYSIS, SCIA 2017, PT II, 2017, 10270 : 314 - 325
  • [44] Monte Carlo Simulation of X-Ray Spectra in Mammography and Contrast-Enhanced Digital Mammography Using the Code PENELOPE
    Cunha, Diego M.
    Tomal, Alessandra
    Poletti, Martin E.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (02) : 495 - 502
  • [45] Radiologic diagnosis of breast cancer. Part 1: Pathology and X-ray mammography
    Schulz-Wendtland, R
    Sinn, HP
    RADIOLOGE, 2004, 44 (05): : 517 - 538
  • [46] Evaluation of a digital X-ray detector based on a phosphor-coated CCD for mammography
    Taibi, A
    DelGuerra, A
    Gambaccini, M
    Marziani, M
    Tuffanelli, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 392 (1-3) : 210 - 213
  • [47] Influence of anode/filtration setup on X-ray multimeter energy response in mammography applications
    Kojic, Andrea
    Krzanovic, Nikola
    Zivanovic, Milos
    Toroi, Paula
    Bakrac, Luka
    Bozovic, Predrag
    Petrovic, Jelena Stankovic
    RADIATION MEASUREMENTS, 2024, 174
  • [48] A SOFTWARE TOOL TO MEASURE THE GEOMETRIC DISTORTION IN X-RAY IMAGE SYSTEMS
    Prieto, Gabriel
    Guibelalde, Eduardo
    Chevalier, Margarita
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [49] Measurement of breast-tissue x-ray attenuation by spectral mammography: solid lesions
    Fredenberg, Erik
    Kilburn-Toppin, Fleur
    Willsher, Paula
    Moa, Elin
    Danielsson, Mats
    Dance, David R.
    Young, Kenneth C.
    Wallis, Matthew G.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (07) : 2595 - 2612
  • [50] Power spectrum analysis of the x-ray scatter signal in mammography and breast tomosynthesis projections
    Sechopoulos, Ioannis
    Bliznakova, Kristina
    Fei, Baowei
    MEDICAL PHYSICS, 2013, 40 (10)