A nonparametric measure of noise in x-ray diagnostic images-mammography

被引:1
|
作者
Anton, M. [1 ]
Maeder, U. [2 ]
Schopphoven, S. [3 ]
Reginatto, M. [1 ]
机构
[1] Phys Tech Bundesanstalt Braunschweig & Berlin, Berlin, Germany
[2] Univ Appl Sci, Inst Med Phys & Radiat Protect, Giessen, Germany
[3] Reference Ctr Mammog Screening Southwest Germany, Giessen, Germany
关键词
quality assurance; mammography; noise measure; non-maximum suppression; nonparametric; PATIENT-SPECIFIC QUANTIFICATION; NO-REFERENCE; QUALITY ASSESSMENT; OBSERVER PERFORMANCE; AUTOMATED TECHNIQUE; PARAMETER;
D O I
10.1088/1361-6560/acb485
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. In x-ray diagnostics, modern image reconstruction or image processing methods may render established methods of image quality assessment inadequate. Task specific quality assessment by using model observers has the disadvantage of being very labour-intensive. Therefore, it appears highly desirable to develop novel image quality parameters that neither rely on the linearity and the shift-invariace of the imaging system nor require the acquisition of hundreds of images as is necessary for the application of model observers, and which can be derived directly from diagnostic images. Approach. A new measure for the noise based on non-maximum-suppression images is defined and its properties are explored using simulated images before it is applied to an exposure series of mammograms of a homogeneous phantom and a 3D-printed breast phantom to demonstrate its usefulness under realistic conditions. Main results. The new noise parameter cannot only be derived from images with a homogeneous background but it can be extracted directly from images containing anatomic structures and is proportional to the standard deviation of the noise. At present, the applicability is restricted to mammography, which satisfies the assumption of short covariance length of the noise. Significance. The new measure of the noise is but a first step of the development of a set of parameters that are required to quantify image quality directly from diagnostic images without relying on the assumption of a linear, shift-invariant system, e.g. by providing measures of sharpness, contrast and structural complexity, in addition to the noise measure. For mammography, a convenient method is now available to quantify noise in processed diagnostic images.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Evaluation of the effect of silicone breast inserts on X-ray mammography and breast tomosynthesis images: A Monte Carlo simulation study
    Daskalaki, A.
    Bliznakova, K.
    Pallikarakis, N.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (02): : 353 - 361
  • [22] A refractive x-ray lens for scanned-slit digital mammography
    Cederström, B
    Cahn, RN
    Danielsson, M
    Lundqvist, M
    Nygren, DR
    MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 : 407 - 416
  • [23] Energy selective laser-based x-ray source for mammography
    Krol, A
    Kieffer, JC
    Jiang, ZM
    Huba, W
    Chamberlain, CC
    Yu, JF
    PHYSICS OF MEDICAL IMAGING, 1998, 3336 : 87 - 94
  • [24] Advantages of quasi-monochromatic X-ray sources in absorption mammography
    Oliva, P.
    Golosio, B.
    Stumbo, S.
    Carpinelli, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 608 (01) : S106 - S108
  • [25] Reduction of scattered radiation dose by X-ray shielding during mammography
    Koo, Bon-Yeoul
    Lee, Kwang-Sung
    RADIATION PHYSICS AND CHEMISTRY, 2020, 177
  • [26] Theoretical considerations for X-ray phase contrast mammography by Thomson source
    Cedola, A.
    Bukreeva, I.
    Lagomarsino, S.
    Petrillo, V.
    Maroli, C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 608 (01) : S23 - S27
  • [27] Detective quantum efficiency dependence on x-ray energy weighting in mammography
    Cahn, RN
    Cederström, B
    Danielsson, M
    Hall, A
    Lundqvist, M
    Nygren, D
    MEDICAL PHYSICS, 1999, 26 (12) : 2680 - 2683
  • [28] Validation of X-Ray Spectra in Screening Mammography Simulated with Monte Carlo
    Talbi, Mohammed
    El Mansouri, M'hamed
    Oustous, Aziz
    Nhila, Oussama
    Sebihi, Rajaa
    Khalis, Mohammed
    MOSCOW UNIVERSITY PHYSICS BULLETIN, 2021, 76 (SUPPL 1) : S30 - S35
  • [29] Validation of X-Ray Spectra in Screening Mammography Simulated with Monte Carlo
    Mohammed Talbi
    M’hamed El Mansouri
    Aziz Oustous
    Oussama Nhila
    Rajaa Sebihi
    Mohammed Khalis
    Moscow University Physics Bulletin, 2021, 76 : S30 - S35
  • [30] Design of a novel phase contrast X-ray imaging system for mammography
    Munro, Peter R. T.
    Ignatyev, Konstantin
    Speller, Robert D.
    Olivo, Alessandro
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 652 (01) : 824 - 828