A nonparametric measure of noise in x-ray diagnostic images-mammography

被引:1
|
作者
Anton, M. [1 ]
Maeder, U. [2 ]
Schopphoven, S. [3 ]
Reginatto, M. [1 ]
机构
[1] Phys Tech Bundesanstalt Braunschweig & Berlin, Berlin, Germany
[2] Univ Appl Sci, Inst Med Phys & Radiat Protect, Giessen, Germany
[3] Reference Ctr Mammog Screening Southwest Germany, Giessen, Germany
关键词
quality assurance; mammography; noise measure; non-maximum suppression; nonparametric; PATIENT-SPECIFIC QUANTIFICATION; NO-REFERENCE; QUALITY ASSESSMENT; OBSERVER PERFORMANCE; AUTOMATED TECHNIQUE; PARAMETER;
D O I
10.1088/1361-6560/acb485
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. In x-ray diagnostics, modern image reconstruction or image processing methods may render established methods of image quality assessment inadequate. Task specific quality assessment by using model observers has the disadvantage of being very labour-intensive. Therefore, it appears highly desirable to develop novel image quality parameters that neither rely on the linearity and the shift-invariace of the imaging system nor require the acquisition of hundreds of images as is necessary for the application of model observers, and which can be derived directly from diagnostic images. Approach. A new measure for the noise based on non-maximum-suppression images is defined and its properties are explored using simulated images before it is applied to an exposure series of mammograms of a homogeneous phantom and a 3D-printed breast phantom to demonstrate its usefulness under realistic conditions. Main results. The new noise parameter cannot only be derived from images with a homogeneous background but it can be extracted directly from images containing anatomic structures and is proportional to the standard deviation of the noise. At present, the applicability is restricted to mammography, which satisfies the assumption of short covariance length of the noise. Significance. The new measure of the noise is but a first step of the development of a set of parameters that are required to quantify image quality directly from diagnostic images without relying on the assumption of a linear, shift-invariant system, e.g. by providing measures of sharpness, contrast and structural complexity, in addition to the noise measure. For mammography, a convenient method is now available to quantify noise in processed diagnostic images.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] A nonparametric measure of contrast in x-ray images
    Anton, M.
    Reginatto, M.
    Schopphoven, S.
    Jaoude, C. Abou
    Maeder, U.
    Fiebich, M.
    Mauter, F.
    Sechopoulos, I
    van Engen, R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (15)
  • [2] Registration of vibro-acoustography images and x-ray mammography
    Hosseini, H. Gholam
    Alizad, A.
    Fatemi, M.
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 1846 - 1849
  • [3] ASSESSMENT OF X-RAY FIELD ALIGNMENT IN MAMMOGRAPHY
    KOTRE, CJ
    ROBSON, KJ
    FAULKNER, K
    BRITISH JOURNAL OF RADIOLOGY, 1993, 66 (782) : 155 - 157
  • [4] Measured low-energy x-ray spectra of interest in diagnostic radiology and mammography
    Hernandez-Guzman, Abel
    Moreno-Ramirez, Adriana
    Massillon-JL, Guerda
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (21)
  • [5] The x-ray sensitivity of amorphous selenium for mammography
    Stone, MF
    Zhao, W
    Jacak, BV
    O'Connor, P
    Yu, B
    Rehak, P
    MEDICAL PHYSICS, 2002, 29 (03) : 319 - 324
  • [6] Elimination of gridlines in X-ray imaging for mammography
    Maruyama, Toshinori
    Yamamoto, Hideki
    IST 2006: PROCEEDINGS OF THE 2006 IEEE INTERNATIONAL WORKSHOP ON IMAGING SYSTEMS AND TECHNIQUES, 2006, : 103 - +
  • [7] CLASSIFICATION OF BREAST DENSITY IN X-RAY MAMMOGRAPHY
    Remes, Vaclav
    Haindl, Michal
    2015 INTERNATIONAL WORKSHOP ON COMPUTATIONAL INTELLIGENCE FOR MULTIMEDIA UNDERSTANDING (IWCIM), 2015,
  • [8] X-Ray Coherent Scatter Mammography Simulation
    Hassan, L. R.
    MacDonald, C. A.
    MEDICAL PHYSICS, 2014, 41 (06) : 145 - +
  • [9] X-ray imaging of a synthetic mammography structure
    Beliaevskaya, EA
    Gambaccini, M
    Ingal, VN
    Manushkin, AA
    Rustichelli, F
    Shilstein, SS
    PHYSICA MEDICA, 1998, 14 (01) : 19 - 23
  • [10] Multitapered x-ray capillary optics for mammography
    Bradford, CD
    Peppler, WW
    Ross, RE
    MEDICAL PHYSICS, 2002, 29 (06) : 1097 - 1108