Assessment of consistency in aortic valve sizing between surgical and transcatheter aortic valve replacement

被引:2
作者
Jastrzebski, Jan [1 ]
Dabrowski, Maciej [1 ]
Kusmierski, Krzysztof [2 ]
Kepka, Cezary [3 ]
Mioduszewska, Aleksandra [1 ]
Chmielak, Zbigniew [1 ]
Witkowski, Adam [1 ]
Kadziela, Jacek [1 ]
机构
[1] Natl Inst Cardiol, Dept Intervent Cardiol & Angiol, Warsaw, Poland
[2] Natl Inst Cardiol, Dept Cardiac Surg & Transplantol, Warsaw, Poland
[3] Natl Inst Cardiol, Dept Coronary Artery & Struct Heart Dis, Warsaw, Poland
来源
POSTEPY W KARDIOLOGII INTERWENCYJNEJ | 2023年 / 19卷 / 01期
关键词
computed tomography; aortic stenosis; patient prosthesis mismatch; EXPERT CONSENSUS DOCUMENT; HEART-VALVE; IMPLANTATION; MISMATCH;
D O I
10.5114/aic.2023.125154
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: One of the crucial aspects of transcatheter aortic valve replacement (TAVR) and surgical aortic valve replacement (SAVR) is the valve prosthesis selection.Aim: To assess the consistency of the aortic valve sizing in SAVR and TAVR by comparing the sizes of aortic prostheses selected based on the intraprocedural annulus measurements and simulation of the TAVR planning.Material and methods: The study comprised of 167 patients with aortic stenosis treated with SAVR. Simulation of the pros-thesis sizing blinded to the SAVR results was performed based on the assessment of cardiac computed tomography (CCT) images.Results: Based on the CCT images, the average value of the aortic annulus diameter was 25.4 +/- 3.0 mm. Aortic valve calcifica-tions were mild in 29 cases, moderate in 78 cases, and severe in 53 cases. The sizes of the valves recommended by the simulations were larger than valves surgically implanted in 98.6% of patients for self-expanding and in 91.7% of patients for balloon-expandable prostheses. The average difference for self-expanding prostheses was 6.4 mm and 4.5 mm for balloon expandable valves. Addition-ally, a negative correlation was observed for the difference in prosthesis size and size of the valve used by surgeons.Conclusions: There is a systematic difference between sizes of aortic prostheses used in SAVR and TAVR. Further studies are needed to evaluate if the difference in prosthesis size selection contributes to the frequency of prosthesis-patient mismatch phe-nomenon and burden of high postoperative mean transaortic gradient.
引用
收藏
页码:40 / 46
页数:7
相关论文
共 13 条
[1]   SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR) [J].
Achenbach, Stephan ;
Delgado, Victoria ;
Hausleiter, Joerg ;
Schoenhagen, Paul ;
Min, James K. ;
Leipsic, Jonathon A. .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (06) :366-380
[2]   Third-Generation Balloon and Self-Expandable Valves for Aortic Stenosis in Large and Extra-Large Aortic Annuli From the TAVR-LARGE Registry [J].
Armijo, German ;
Tang, Gilbert H. L. ;
Kooistra, Nynke ;
Ferreira-Neto, Alfredo Nunes ;
Toggweiler, Stefan ;
Amat-Santos, Ignacio J. ;
Keller, Lukas S. ;
Urena, Marina ;
Ahmad, Hasan ;
Soto, Jose Tafur ;
Munoz-Garcia, Erika ;
Regueiro, Ander ;
Leenders, Geert E. ;
Tirado-Conte, Gabriela ;
Sengupta, Aditya ;
McInerney, Angela ;
Couture, Thomas ;
Herreros, Oscar Cuevas ;
Rodriguez-Gabella, Tania ;
Kini, Annapoorna ;
Ahmed, Mohammed ;
Zaid, Syed ;
Gonzalo, Nieves ;
Nunez-Gil, Ivan J. ;
Munoz-Garcia, Antonio J. ;
Jimenez-Quevedo, Pilar ;
Fernandez-Ortiz, Antonio ;
Himbert, Dominique ;
Nietlispach, Fabian ;
Stella, Pieter ;
Dangas, George D. ;
Escaned, Javier ;
Macaya, Carlos ;
Rodes-Cabau, Josep ;
Nombela-Franco, Luis .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (08) :E009047
[3]   Comparison of the Hemodynamic Performance of Percutaneous and Surgical Bioprostheses for the Treatment of Severe Aortic Stenosis [J].
Clavel, Marie-Annick ;
Webb, John G. ;
Pibarot, Philippe ;
Altwegg, Lukas ;
Dumont, Eric ;
Thompson, Chris ;
De Larochelliere, Robert ;
Doyle, Daniel ;
Masson, Jean-Bernard ;
Bergeron, Sebastien ;
Bertrand, Olivier F. ;
Rodes-Cabau, Josep .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (20) :1883-1891
[4]   Essential information on surgical heart valve characteristics for optimal valve prosthesis selection: expert consensus document from the European Association for Cardio-Thoracic Surgery (EACTS)-The Society of Thoracic Surgeons (STS)-American Association for Thoracic Surgery (AATS) Valve Labelling Task Force [J].
Durko, Andras P. ;
Pibarot, Philippe ;
Atluri, Pavan ;
Bapat, Vinayak ;
Cameron, Duke E. ;
Casselman, Filip P. A. ;
Chen, Edward P. ;
Dahle, Gry ;
Elefteriades, John A. ;
Lancellotti, Patrizio ;
Prager, Richard L. ;
Rosenhek, Raphael ;
Speir, Alan ;
Stijnen, Marco ;
Tasca, Giordano ;
Yoganathan, Ajit ;
Walther, Thomas ;
De Paulis, Ruggero .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2021, 59 (01) :54-64
[5]   Aortic Stenosis and Small Aortic Annulus Clinical Challenges and Current Therapeutic Alternatives [J].
Freitas-Ferraz, Afonso B. ;
Tirado-Conte, Gabriela ;
Dagenais, Francois ;
Ruel, Marc ;
Al-Atassi, Talal ;
Dumont, Eric ;
Mohammadi, Siamak ;
Bernier, Mathieu ;
Pibarot, Philippe ;
Rodes-Cabau, Josep .
CIRCULATION, 2019, 139 (23) :2685-2702
[6]   Progress and Current Status of Percutaneous Aortic Valve Replacement: Results of Three Device Generations of the CoreValve Revalving System [J].
Grube, Eberhard ;
Buellesfeld, Lutz ;
Mueller, Ralf ;
Sauren, Barthel ;
Zickmann, Bernfried ;
Nair, Dinesh ;
Beucher, Harald ;
Felderhoff, Thomas ;
Iversen, Stein ;
Gerckens, Ulrich .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2008, 1 (03) :167-175
[7]   Computed Tomography-Based Indexed Aortic Annulus Size to Predict Prosthesis-Patient Mismatch Transcatheter Aortic Valve Replacement Versus Surgical Aortic Valve Replacement in the SURTAVI Trial [J].
Head, Stuart J. ;
Reardon, Michael J. ;
Deeb, G. Michael ;
Van Mieghem, Nicolas M. ;
Popma, Jeffrey J. ;
Gleason, Thomas G. ;
Williams, Mathew R. ;
Radhakrishnan, Sam ;
Fremes, Stephen ;
Oh, Jae K. ;
Chang, Yanping ;
Boulware, Michael J. ;
Kappetein, Arie Pieter .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (04)
[8]   Prosthesis-Patient Mismatch in Patients Undergoing Transcatheter Aortic Valve Replacement From the STS/ACC TVT Registry [J].
Herrmann, Howard C. ;
Daneshvar, Samuel A. ;
Fonarow, Gregg C. ;
Stebbins, Amanda ;
Vemulapalli, Sreekanth ;
Desai, Nimesh D. ;
Malenka, David J. ;
Thourani, Vinod H. ;
Rymer, Jennifer ;
Kosinski, Andrzej S. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (22) :2701-2711
[9]   Prosthesis-patient mismatch after transcatheter aortic valve implantation with the Medtronic-Corevalve bioprosthesis [J].
Jilaihawi, Hasan ;
Chin, Derek ;
Spyt, Tomasz ;
Jeilan, Mohamed ;
Vasa-Nicotera, Mariuca ;
Bence, Johan ;
Logtens, Elaine ;
Kovac, Jan .
EUROPEAN HEART JOURNAL, 2010, 31 (07) :857-864
[10]   Does the use of stentless aortic valves in a subcoronary position prevent patient-prosthesis mismatch for small aortic annulus? [J].
Lopez, Stephane ;
Mathieu, Patrick ;
Pibarot, Philippe ;
Mohammadi, Siamak ;
Dagenais, Francois ;
Voisine, Pierre ;
Dumesnil, Jean ;
Doyle, Daniel .
JOURNAL OF CARDIAC SURGERY, 2008, 23 (04) :331-335